Home › Power Source / Network › 2AR-FE (BATTERY / CHARGING) › CHARGING SYSTEM › 2017.09–2021.02
RM33A0E _57 Power Source / Network _065331 2AR-FE BATTERY / CHARGING _0328305 CHARGING SYSTEM C

2AR-FE BATTERY / CHARGING  CHARGING SYSTEM  P161A  Lost Communication with Alternator  


DESCRIPTION

The ECM communicates with the generator assembly via LIN communication. If a LIN communication error is detected, the ECM stores this DTC.

DTC No. Detection Item DTC Detection Condition Trouble Area Warning Indicate Memory
P161A Lost Communication with Alternator Generator assembly or ECM communication stops for approximately 17 minutes or more with the ignition switch ON.
(1 trip detection logic)
·

Wire harness and connector

·

Generator assembly

·

ECM


Charge warning is not displayed DTC stored

WIRING DIAGRAM

A340530E58
1.51,3.167 5.177,3.365 3.667,0.198 10 false : LIN Communication Line 5.135,2.521 6.365,2.719 1.229,0.198 10 false C58 1.667,2.208 2.125,2.406 0.458,0.198 10 false C60 1.667,2.375 4.417,2.573 2.75,0.198 10 false Generator Assembly 4.896,1.698 5.354,1.896 0.458,0.198 10 false LIN 3.125,1.531 3.281,1.729 0.156,0.198 10 false 2 4.615,1.531 4.927,1.729 0.313,0.198 10 false 31 2.771,1.708 3.229,1.906 0.458,0.198 10 false LIN 5.115,2.688 6.344,2.885 1.229,0.198 10 false ECM

PROCEDURE

1.CHECK CHARGING SYSTEM

Result:
Proceed to
OK
NG



OK

2.CHECK HARNESS AND CONNECTOR (ECM - GENERATOR ASSEMBLY)

NG

REPAIR OR REPLACE CHARGING SYSTEM

2.CHECK HARNESS AND CONNECTOR (ECM - GENERATOR ASSEMBLY)
a.

Disconnect the C58 ECM connector.


b.

Disconnect the C60 generator assembly connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
C58-31 (LIN) - C60-2 (LIN) Always Below 1 Ω
C58-31 (LIN) or C60-2 (LIN) - body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR