If the temperature of the air that blows from the left and right front registers differs, even though the same temperature is set for both sides, the following factors may be the cause.
| Symptom | Factor |
|---|---|
| Temperature of outlet air is cooler on left or right side
(when same temperature set for both sides) |
·
Compressor assembly with pulley (compressor solenoid) malfunction*1 ·
Cooler compressor assembly (compressor solenoid) malfunction*2 ·
Magnet clutch assembly malfunction*2 ·
Refrigerant volume (low) ·
Mechanical locking of damper and damper link ·
Automatic light control sensor malfunction ·
Harness or connector |
| Temperature of outlet air is warmer on left or right side
(when same temperature set for both sides) |
·
Mechanical locking of damper and damper link ·
Blockage in heater radiator unit sub-assembly ·
Harness or connector |
*1: for 2AR-FE, A25A-FKS
*2: for 6AR-FSE, 2GR-FKS
If DTC B1244 is output, troubleshoot for DTC B1244 first.
w/ Automatic Headlight Beam Level Control System: Click hereVehicle Exterior>LIGHTING (EXT)>LIGHTING SYSTEM (w/ Automatic Headlight Beam Level Control System)>B1244
w/o Automatic Headlight Beam Level Control System: Click hereVehicle Exterior>LIGHTING (EXT)>LIGHTING SYSTEM (w/o Automatic Headlight Beam Level Control System)>B1244
The air conditioning system uses the CAN communication system. Inspect the communication functions by following How to Proceed with Troubleshooting. Troubleshoot the air conditioning system after confirming that the communication systems are functioning properly.
| Result | Proceed to |
|---|---|
| When using cooling function | A |
| When using heater function | B |
A
B
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Utility / Refrigerant Gas Volume Check.
| Tester Display |
|---|
| Refrigerant Gas Volume Check |
Check that the following conditions are met and perform the refrigerant shortage check according to the display on the GTS.
| Item | Condition |
|---|---|
| A/C switch | On |
| Ambient temperature* | 0 to 49°C (32 to 120°F) |
| Blower speed | HI |
*: If the ambient temperature is not within the range shown, do not perform this check.
| Result | Amount of Refrigerant |
|---|---|
| Refrigerant correct | Correct |
| Refrigerant shortage | Insufficient |
"Refrigerant correct" is displayed on the GTS.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Active Test.
Perform the Active Test according to the display on the GTS.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Air Mix Servo Targ Pulse(D) | No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) pulse | Min.: 128
Max.: 383 |
for LHD:
Operates between 165 to 257 pulses for RHD:
Operates between 255 to 347 pulses |
| Air Mix Servo Targ Pulse(P) | No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) pulse | Min.: 128
Max.: 383 |
for LHD:
Operates between 255 to 347 pulses for RHD:
Operates between 165 to 257 pulses |
| Rear Air Mix Servo Targ Pulse | No. 3 air conditioning radiator damper servo sub-assembly pulse | Min.: 128
Max.: 383 |
·
Operates between 165 to 257 pulses ·
* |
*: for 3 Zone Type
| Tester Display |
|---|
| Air Mix Servo Targ Pulse(D) |
| Tester Display |
|---|
| Air Mix Servo Targ Pulse(P) |
| Tester Display |
|---|
| Rear Air Mix Servo Targ Pulse |
Each damper servo motor operates.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the M1 automatic light control sensor connector.
Disconnect the K52 main body ECU (multiplex network body ECU) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| M1-1 (CLTB) - K52-23 (CLTB) | Always | Below 1 Ω |
| M1-2 (CLTE) - K52-25 (CLTE) | Always | Below 1 Ω |
| M1-4 (CLTS) - K52-24 (CLTS) | Always | Below 1 Ω |
| M1-1 (CLTB) or K52-23 (CLTB) - Other terminals and body ground | Always | 10 kΩ or higher |
| M1-2 (CLTE) or K52-25 (CLTE) - Other terminals and body ground | Always | 10 kΩ or higher |
| M1-4 (CLTS) or K52-24 (CLTS) - Other terminals and body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the automatic light control sensor.
Click hereVehicle Interior>HEATING / AIR CONDITIONING>SOLAR SENSOR>REMOVAL
Inspect the automatic light control sensor.
Click hereVehicle Interior>HEATING / AIR CONDITIONING>SOLAR SENSOR>INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Bleed air from cooling system.
for 2AR-FE: Click hereEngine / Hybrid System>2AR-FE (COOLING)>COOLANT>REPLACEMENT
for A25A-FKS: Click hereEngine / Hybrid System>A25A-FKS (COOLING)>COOLANT>REPLACEMENT
for 6AR-FSE: Click hereEngine / Hybrid System>6AR-FSE (COOLING)>COOLANT>REPLACEMENT
for 2GR-FKS: Click hereEngine / Hybrid System>2GR-FKS (COOLING)>COOLANT>REPLACEMENT
| Proceed to |
|---|
| NEXT |
NEXT
Set the same temperature for the left and right sides and check that the air that blows from the left and right front registers is the same temperature.
The air from the left and right front registers is the same temperature.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Active Test.
Perform the Active Test according to the display on the GTS.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Air Mix Servo Targ Pulse(D) | No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) pulse | Min.: 128
Max.: 383 |
for LHD:
Operates between 165 to 257 pulses for RHD:
Operates between 255 to 347 pulses |
| Air Mix Servo Targ Pulse(P) | No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) pulse | Min.: 128
Max.: 383 |
for LHD:
Operates between 255 to 347 pulses for RHD:
Operates between 165 to 257 pulses |
| Rear Air Mix Servo Targ Pulse | No. 3 air conditioning radiator damper servo sub-assembly pulse | Min.: 128
Max.: 383 |
·
Operates between 165 to 257 pulses ·
* |
*: for 3 Zone Type
| Tester Display |
|---|
| Air Mix Servo Targ Pulse(D) |
| Tester Display |
|---|
| Air Mix Servo Targ Pulse(P) |
| Tester Display |
|---|
| Rear Air Mix Servo Targ Pulse |
Each damper servo motor operates.
| Proceed to |
|---|
| OK |
| NG |
OK
NG