The necessary procedures (adjustment, calibration, initialization or registration) that must be performed after parts are removed and installed, or replaced during generator assembly removal/installation are shown below.
1. PRECAUTION
After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) battery terminal notices before proceeding with work.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION
2.DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL
3.REMOVE V-RIBBED BELT
27020
4.REMOVE GENERATOR ASSEMBLY
Disconnect the generator assembly connector.
Open the terminal cap.
Remove the nut and disconnect the wire harness from terminal B.
Remove the bolt and separate the wire harness clamp bracket from the generator assembly.
Remove the 2 nuts, bolt and generator assembly.