Home › Power Source / Network › A25A-FKS (BATTERY / CHARGING) › GENERATOR (for 150 A Type) › from 2021.02
RM33A0E _57 Power Source / Network _065349 A25A-FKS BATTERY / CHARGING _0462232 GENERATOR(for 150 A Type) G

A25A-FKS BATTERY / CHARGING  GENERATOR(for 150 A Type)  ON-VEHICLE INSPECTION  


CAUTION / NOTICE / HINT

NOTICE:
·

Do not remove the generator pulley cap.

·

If the generator pulley cap is removed, replace the generator pulley cap and generator pulley with clutch with new ones as the correct grease amount cannot be confirmed.



HINT:

If it is confirmed that the generator assembly is not generating power, it is not necessary to perform the counterclockwise check as another malfunction is suspected.


PROCEDURE

Hide 1.REMOVE V-RIBBED BELT

Hide 27415 2.INSPECT GENERATOR PULLEY WITH CLUTCH

a.
A406402C01
0,0 0,0 false
V100135

Counterclockwise
V100136

Clockwise


Check that the generator pulley with clutch operates in accordance with the following table.

Standard:
Counterclockwise Clockwise
Spins Freely Lock


HINT:

If the generator pulley with clutch does not turn smoothly, does not operate as specified, or an abnormal sound is output, replace it with a new one.



Hide 3.INSTALL V-RIBBED BELT