The necessary procedures (adjustment, calibration, initialization, or registration) that must be performed after parts are removed and installed, or replaced during hybrid battery terminal block removal/installation are shown below.
Orange wire harnesses and connectors indicate high-voltage circuits. To prevent electric shock, always follow the procedure described in the repair manual.
To prevent electric shock, wear insulated gloves when working on wire harnesses and components of the high voltage system.
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION
G9510
1.REMOVE HV BATTERY
G920NB
2.REMOVE UPPER HV BATTERY COVER SUB-ASSEMBLY
G92Q1
3.REMOVE NO. 1 HV BATTERY SHIELD PANEL
G92Z2
4.REMOVE HYBRID BATTERY TERMINAL BLOCK
Be sure to wear insulated gloves and protective goggles.
Remove the bolt to separate the hybrid battery terminal block from the HV battery.
Disconnect the 2 hybrid battery terminal block connectors to remove the hybrid battery terminal block.
Insulate the disconnected high-voltage connectors with insulating tape.