Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM › 2017.09–2018.04
RM33C0E _58 Vehicle Interior _065464 HEATING / AIR CONDITIONING _0329891 AIR CONDITIONING SYSTEM J

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM  Air Vent Temperature does not Change and Right Vent is Different from Left and Vice Versa (Same Left/Right Temperature Setting)  


DESCRIPTION

If the temperature of the air that blows from the left and right front registers differs, even though the same temperature is set for both sides, the following factors may be the cause.

Symptom Factor
Temperature of outlet air is cooler on left or right side (when same temperature set for both sides)
·

Compressor with motor assembly malfunction

·

Refrigerant volume (low)

·

Mechanical locking of damper and damper link

·

Automatic light control sensor malfunction

·

Harness or connector


Temperature of outlet air is warmer on left or right side (when same temperature set for both sides)
·

Mechanical locking of damper and damper link

·

Blockage in heater radiator unit sub-assembly

·

Harness or connector



WIRING DIAGRAM

E375537E01
0.063,1.01 2.292,1.26 2.229,0.25 10 false Air Conditioning Amplifier Assembly 1.896,4.031 3.927,4.229 2.031,0.198 10 false Automatic Light Control Sensor 4.865,4.146 6.51,4.542 1.646,0.396 10 false Main Body ECU (Multiplex Network Body ECU) 1.042,4.479 3.073,4.677 2.031,0.198 10 false : CAN Communication Line 3.146,1.656 3.604,1.844 0.458,0.188 10 false CLTB 4.875,1.646 5.333,1.833 0.458,0.188 10 false CLTB 3.167,2.427 3.625,2.615 0.458,0.188 10 false CLTS 4.875,2.448 5.333,2.635 0.458,0.188 10 false CLTS 3.167,3.115 3.625,3.302 0.458,0.188 10 false CLTE 4.854,3.115 5.313,3.302 0.458,0.188 10 false CLTE 3.604,1.635 4.063,1.823 0.458,0.188 10 false 1 4.583,1.635 5.042,1.823 0.458,0.188 10 false 23 3.625,2.417 4.083,2.604 0.458,0.188 10 false 4 3.625,3.094 4.083,3.281 0.458,0.188 10 false 2 4.615,2.396 5.073,2.583 0.458,0.188 10 false 24 4.594,3.073 5.052,3.26 0.458,0.188 10 false 25 1.896,3.854 2.354,4.042 0.458,0.188 10 false M1 4.865,3.99 5.323,4.177 0.458,0.188 10 false K52

CAUTION / NOTICE / HINT

NOTICE:
·
·

The air conditioning system uses the CAN communication system. Inspect the communication functions by following How to Proceed with Troubleshooting. Troubleshoot the air conditioning system after confirming that the communication systems are functioning properly.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM>HOW TO PROCEED WITH TROUBLESHOOTING



PROCEDURE

1.CHECK WHEN MALFUNCTION OCCURS
Result:
Result Proceed to
When using cooling function A
When using heater function B



A

2.PERFORM REFRIGERANT SHORTAGE CHECK

B

6.BLEED AIR FROM COOLING SYSTEM
2.PERFORM REFRIGERANT SHORTAGE CHECK
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Turn the GTS on.


d.

Enter the following menus: Body Electrical / Air Conditioner / Utility / Refrigerant Gas Volume Check.

Body Electrical > Air Conditioner > Utility
Tester Display
Refrigerant Gas Volume Check
50005 121 3186

e.

Check that the following conditions are met and perform the refrigerant shortage check according to the display on the GTS.

Measurement Condition:
Item Condition
A/C switch On
Ambient temperature* 0 to 49°C (32 to 120°F)
Blower speed HI

*: If the ambient temperature is not within the range shown, do not perform this check.


Result:
Result Amount of Refrigerant
Refrigerant correct Correct
Refrigerant shortage Insufficient


OK:

"Refrigerant correct" is displayed on the GTS.


Result:
Proceed to
OK
NG



OK

3.PERFORM ACTIVE TEST USING GTS

NG

3.PERFORM ACTIVE TEST USING GTS
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Turn the GTS on.


d.

Enter the following menus: Body Electrical / Air Conditioner / Active Test.


e.

Perform the Active Test according to the display on the GTS.

Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
Air Mix Servo Targ Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) pulse Min.: 128
Max.: 383
for LHD

Operates between 165 to 257 pulses


for RHD

Operates between 255 to 347 pulses


Air Mix Servo Targ Pulse(P) No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) pulse Min.: 128
Max.: 383
for LHD:

Operates between 255 to 347 pulses


for RHD:

Operates between 165 to 257 pulses


Rear Air Mix Servo Targ Pulse No. 3 air conditioning radiator damper servo sub-assembly pulse Min.: 128
Max.: 383
Operates between 165 to 257 pulses*

*: for 3 Zone Type


Body Electrical > Air Conditioner > Active Test
Tester Display
Air Mix Servo Targ Pulse(D)
50004 121 24
Body Electrical > Air Conditioner > Active Test
Tester Display
Air Mix Servo Targ Pulse(P)
50004 121 25
Body Electrical > Air Conditioner > Active Test
Tester Display
Rear Air Mix Servo Targ Pulse
50004 121 36
OK:

Each damper servo motor operates.



Result:
Proceed to
OK
NG



OK

4.CHECK HARNESS AND CONNECTOR (AUTOMATIC LIGHT CONTROL SENSOR - MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU))

NG

GO TO DTC TROUBLESHOOTING PROCEDURE FOR MALFUNCTIONING DAMPER SERVO MOTOR

4.CHECK HARNESS AND CONNECTOR (AUTOMATIC LIGHT CONTROL SENSOR - MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU))
a.

Disconnect the M1 automatic light control sensor connector.


b.

Disconnect the K52 main body ECU (multiplex network body ECU) connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
M1-1 (CLTB) - K52-23 (CLTB) Always Below 1 Ω
M1-2 (CLTE) - K52-25 (CLTE) Always Below 1 Ω
M1-4 (CLTS) - K52-24 (CLTS) Always Below 1 Ω
M1-1 (CLTB) or K52-23 (CLTB) - Other terminals and body ground Always 10 kΩ or higher
M1-2 (CLTE) or K52-25 (CLTE) - Other terminals and body ground Always 10 kΩ or higher
M1-4 (CLTS) or K52-24 (CLTS) - Other terminals and body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

5.INSPECT AUTOMATIC LIGHT CONTROL SENSOR

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

5.INSPECT AUTOMATIC LIGHT CONTROL SENSOR
a.

Remove the automatic light control sensor.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>SOLAR SENSOR>REMOVAL


b.

Inspect the automatic light control sensor.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>SOLAR SENSOR>INSPECTION


Result:
Proceed to
OK
NG



OK

INSPECT REFRIGERANT PRESSURE WITH MANIFOLD GAUGE SET

NG

REPLACE AUTOMATIC LIGHT CONTROL SENSOR

6.BLEED AIR FROM COOLING SYSTEM
a.

Bleed air from cooling system.

Click hereEngine / Hybrid System>A25A-FXS (COOLING)>COOLANT>REPLACEMENT


Result:
Proceed to
NEXT



NEXT

7.CHECK OPERATION (AIR CONDITIONING SYSTEM)
7.CHECK OPERATION (AIR CONDITIONING SYSTEM)
a.

Set the same temperature for the left and right sides and check that the air that blows from the left and right front registers is the same temperature.

OK:

The air from the left and right front registers is the same temperature.



Result:
Proceed to
OK
NG



OK

END (MALFUNCTION DUE TO AIR IN COOLING SYSTEM)

NG

8.PERFORM ACTIVE TEST USING GTS
8.PERFORM ACTIVE TEST USING GTS
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Turn the GTS on.


d.

Enter the following menus: Body Electrical / Air Conditioner / Active Test.


e.

Perform the Active Test according to the display on the GTS.

Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
Air Mix Servo Targ Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) pulse Min.: 128
Max.: 383
for LHD

Operates between 165 to 257 pulses


for RHD

Operates between 255 to 347 pulses


Air Mix Servo Targ Pulse(P) No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) pulse Min.: 128
Max.: 383
for LHD:

Operates between 255 to 347 pulses


for RHD:

Operates between 165 to 257 pulses


Rear Air Mix Servo Targ Pulse No. 3 air conditioning radiator damper servo sub-assembly pulse Min.: 128
Max.: 383
Operates between 165 to 257 pulses*

*: for 3 Zone Type


Body Electrical > Air Conditioner > Active Test
Tester Display
Air Mix Servo Targ Pulse(D)
50004 121 24
Body Electrical > Air Conditioner > Active Test
Tester Display
Air Mix Servo Targ Pulse(P)
50004 121 25
Body Electrical > Air Conditioner > Active Test
Tester Display
Rear Air Mix Servo Targ Pulse
50004 121 36
OK:

Each damper servo motor operates.



Result:
Proceed to
OK
NG



OK

REPLACE HEATER RADIATOR UNIT SUB-ASSEMBLY

NG

GO TO DTC TROUBLESHOOTING PROCEDURE FOR MALFUNCTIONING DAMPER SERVO MOTOR