Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM › 2017.09–2018.08
RM33C0E _58 Vehicle Interior _065464 HEATING / AIR CONDITIONING _0329891 AIR CONDITIONING SYSTEM J

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM  No Warm Air Comes Out  


DESCRIPTION

If cool air blows from the registers regardless of the temperature setting of the air conditioning system, the following factors may be the cause.

Symptom Factor
·

No warm air comes out

(Blower control is normal)

·

Outlet air temperature does not increase (Blower control is normal)


·

Engine coolant temperature (low)

·

Refrigerant volume (low)

·

No. 1 air conditioning radiator damper servo sub-assembly malfunction

·

Warm-up control

·

Blockage in heater radiator unit sub-assembly

·

Quick heater assembly malfunction

·

Heater radiator unit sub-assembly malfunction

·

Flow shutting valve (water by-pass hose assembly) malfunction



PROCEDURE

1.CHECK FOR DTC
a.

Check for DTCs.

Powertrain > Engine > Trouble Codes
50001 372
OK:

SFI system DTCs are not output.



Result:
Proceed to
OK
NG



OK

2.READ VALUE USING GTS

NG

2.READ VALUE USING GTS
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Turn the GTS on.


d.

Enter the following menus: Powertrain / Engine / Data List.


e.

Read the Data List according to the display on the GTS.

Powertrain > Engine > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Coolant Temperature Engine coolant temperature Min.: -40°C (-40°F), Max.: 140°C (284°F) 75 to 100°C (167 to 212°F): After warming up This is the engine coolant temperature.
HINT:
·

After warming up the engine, the engine coolant temperature will be 75 to 100°C (167 to 212°F).

·

After a long soak, the engine coolant temperature, intake air temperature and ambient air temperature will be approximately equal.

·

If the value is -40°C (-40°F), or higher than 135°C (275°F), the sensor circuit is open or shorted.

·

Check if the engine overheats if the value indicated is higher than 135°C (275°F).



Powertrain > Engine > Data List
Tester Display
Coolant Temperature
50003 372 205
OK:

After warming up the engine, the temperature value displayed is within the range specified in the normal condition column.



Result:
Proceed to
OK
NG



OK

3.PERFORM ACTIVE TEST USING GTS

NG

3.PERFORM ACTIVE TEST USING GTS
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Turn the GTS on.


d.

Enter the following menus: Body Electrical / Air Conditioner / Active Test.


e.

Perform the Active Test according to the display on the GTS.

Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
Air Mix Servo Targ Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) pulse Min.: 128
Max.: 383
for LHD

Operates between 165 to 257 pulses


for RHD

Operates between 255 to 347 pulses


Air Mix Servo Targ Pulse(P) No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) pulse Min.: 128
Max.: 383
for LHD:

Operates between 255 to 347 pulses


for RHD:

Operates between 165 to 257 pulses


Rear Air Mix Servo Targ Pulse No. 3 air conditioning radiator damper servo sub-assembly pulse Min.: 128
Max.: 383
Operates between 165 to 257 pulses*

*: for 3 Zone Type


Body Electrical > Air Conditioner > Active Test
Tester Display
Air Mix Servo Targ Pulse(D)
50004 121 24
Body Electrical > Air Conditioner > Active Test
Tester Display
Air Mix Servo Targ Pulse(P)
50004 121 25
Body Electrical > Air Conditioner > Active Test
Tester Display
Rear Air Mix Servo Targ Pulse
50004 121 36
OK:

Each damper servo motor operates.



Result:
Proceed to
OK
NG



OK

4.PERFORM ACTIVE TEST USING GTS

NG

GO TO DTC TROUBLESHOOTING PROCEDURE FOR MALFUNCTIONING DAMPER SERVO MOTOR

4.PERFORM ACTIVE TEST USING GTS
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Turn the GTS on.


d.

Enter the following menus: Body Electrical / Air Conditioner / Active Test / Heater Active Level / Data List / Electric Heater Active Level.

Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
Heater Active Level Quick heater assembly Min.: 0
Max.: 2
-
Body Electrical > Air Conditioner > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Electric Heater Active Level Actual electric heater operation level Min.: 0
Max.: 2
Actual operation level of electric heater displayed PTC heater circuit malfunction
Body Electrical > Air Conditioner > Active Test
Active Test Display
Heater Active Level
Data List Display
Electric Heater Active Level
50004 121 33 164

e.

Check that the value of the Data List item Electric Heater Active Level changes in accordance with the set value of the Active Test item Heater Active Level.

OK:
GTS Operation Data List (Electric Heater Active Level)
0 to 2 0 to 2



Result:
Proceed to
OK
NG



OK

REPLACE HEATER RADIATOR UNIT SUB-ASSEMBLY

NG