Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM (for NICKEL METAL HYDRIDE BATTERY)
RM33C0E _51 Engine / Hybrid System _065433 HYBRID / BATTERY CONTROL _0331295 HYBRID CONTROL SYSTEM(for NICKEL METAL HYDRIDE BATTERY) J

HYBRID / BATTERY CONTROL  HYBRID CONTROL SYSTEM(for NICKEL METAL HYDRIDE BATTERY)  Motor High-voltage Circuit  


DESCRIPTION

The cause of the malfunction may be the high-voltage circuit of the motor.

Check the motor internal resistance and the connection condition of the high-voltage line between the inverter and motor to check whether there is an open or short circuit.

Related Parts Check
Area Inspection
Motor cable connection check Check for open or short circuit in the connection condition of the cable from the inverter to the motor.
Motor and motor cable Check the motor (including cable) internal resistance and insulation resistance with body ground to check for an open or short circuit.

WIRING DIAGRAM

C304949E59
1.125,2.427 2.958,2.667 1.833,0.24 10 false : High Voltage Line 2.438,0.458 2.594,0.656 0.156,0.198 10 false W 2.438,0.802 2.594,1 0.156,0.198 10 false U 2.438,1.125 2.594,1.323 0.156,0.198 10 false V 2.677,0.385 2.833,0.583 0.156,0.198 10 false 1 2.677,0.74 2.833,0.938 0.156,0.198 10 false 2 2.667,1.125 2.823,1.323 0.156,0.198 10 false 3 1.094,1.594 2.146,1.76 1.052,0.167 10 false E1 1.083,1.729 3.292,2.281 2.208,0.552 10 false Hybrid Vehicle Transaxle Assembly (Motor (MG2)) 4.906,0.438 5.063,0.635 0.156,0.198 10 false 1 4.917,0.771 5.073,0.969 0.156,0.198 10 false 2 4.917,1.135 5.073,1.333 0.156,0.198 10 false 3 5.052,1.594 5.417,1.792 0.365,0.198 10 false E2 5.052,1.729 7.083,2.26 2.031,0.531 10 false Inverter with Converter Assembly 5.115,0.552 5.271,0.75 0.156,0.198 10 false W 5.115,0.906 5.271,1.104 0.156,0.198 10 false U 5.125,1.25 5.281,1.448 0.156,0.198 10 false V

CAUTION / NOTICE / HINT

This diagnostic procedure is referenced to in the diagnostic procedure of several DTCs.

If the result of this diagnostic procedure is normal, proceed as directed in the procedure for the DTC.

CAUTION:
·
A340358

Before the following operations are conducted, take precautions to prevent electric shock by turning the power switch off, wearing insulated gloves, and removing the service plug grip from HV battery.

-

Inspecting the high-voltage system

-

Disconnecting the low voltage connector of the inverter with converter assembly

-

Disconnecting the low voltage connector of the HV battery


·
A357588

To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.

·
A358042

After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

·
A357589C02
1.573,0.74 2.021,0.427 true 2.094,0.344 2.354,0.51 0.26,0.167 10 false *a
*a Without waiting for 10 minutes


After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM (for NICKEL METAL HYDRIDE BATTERY)>PRECAUTION

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.




NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION


PROCEDURE

1.CHECK INVERTER WITH CONVERTER ASSEMBLY (MOTOR CABLE CONNECTION CONDITION)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Remove the inverter cover from the inverter with converter assembly.


c.
A406955

Check that the bolts for the motor cable are tightened to the specified torque, the motor cable is connected securely, and there are no contact problems.

Specified Condition:

T = 8.0 N*m (82 kgf*cm, 71 in.*lbf)



d.

Disconnect the motor cable from the inverter with converter assembly.


e.

Check for arc marks at the terminals for the motor cable.

Result:
Result Proceed to
The terminals are connected securely and there are no contact problems. There are no arc marks. A
The terminals are not connected securely and there is a contact problem. There are arc marks. B
The terminals are not connected securely and there is a contact problem. There are no arc marks. C
The terminals are connected securely and there are no contact problems. There are arc marks. B



f.

Reconnect the motor cable.


g.

Reinstall the inverter cover.



A

2.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MOTOR (MG2))

B

REPLACE MALFUNCTIONING PARTS

C

CONNECT SECURELY

2.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MOTOR (MG2))
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Remove the inverter cover from the inverter with converter assembly.


c.

Disconnect the motor cable from the inverter with converter assembly.


d.
A407601C09
1.438,0.146 1.771,0.365 0.333,0.219 0.823,1.781 0.865,1.01 true 1.385,1.76 1.365,1 true 1.854,1.76 1.667,1.021 true 2.948,1.802 2.917,1.656 true 1.542,0.188 1.854,0.385 0.313,0.198 10 false E2 0.104,0.125 0.417,0.323 0.313,0.198 10 false *a 0.781,1.813 1.094,2.01 0.313,0.198 10 false W 1.344,1.813 1.656,2.01 0.313,0.198 10 false U 1.844,1.813 2.156,2.01 0.313,0.198 10 false V 2.896,1.844 3.208,2.042 0.313,0.198 10 false *1
*1 Shield Ground
*a Motor Cable
(Inverter with Converter Assembly Side)


Using a milliohmmeter, measure the resistance according to the value(s) in the table below.

HINT:

If the motor (MG2) temperature is high, the resistance will vary greatly from the specification. Therefore, measure the resistance at least 8 hours after the vehicle is stopped.


Standard Resistance:
Tester Connection Condition Specified Condition
E2-1 (W) - E2-2 (U) Power switch off 62.1 to 68.8 mΩ
E2-2 (U) - E2-3 (V) Power switch off 62.1 to 68.8 mΩ
E2-3 (V) - E2-1 (W) Power switch off 62.3 to 69.0 mΩ


HINT:

To correct the variation of the measured resistance due to temperature, use the following formula to calculate the resistance at 20°C (68°F).

R20 = Rt / {1 + 0.00393 X (T - 20)}

The calculation is based on the following:

R20: Resistance at 20°C (68°F) (mΩ)

Rt: Measured resistance (mΩ)

T: Temperature when the resistance is measured (°C (°F).)



e.

Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

NOTICE:

Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.


Standard Resistance:
Tester Connection Condition Specified Condition
E2-1 (W) - Body ground and shield ground Power switch off 100 MΩ or higher
E2-2 (U) - Body ground and shield ground Power switch off 100 MΩ or higher
E2-3 (V) - Body ground and shield ground Power switch off 100 MΩ or higher



f.

Reconnect the motor cable.


g.

Reinstall the inverter cover.


Result:
Proceed to
OK
NG



OK

MOTOR HIGH-VOLTAGE CIRCUIT NORMAL (PERFORM NEXT STEP FOR REFERENCED DTC)

NG

3.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MOTOR CABLE CONNECTION CONDITION)
3.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MOTOR CABLE CONNECTION CONDITION)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Remove the inverter with converter assembly.


c.
A407603

Check that the bolts for the motor cable are tightened to the specified torque, the motor cable is connected securely, and there are no contact problems.

Specified Condition:

T=10 N*m (102 kgf*cm, 7 ft.*lbf)



d.

Disconnect the motor cable from the hybrid vehicle transaxle assembly.


e.

Check for arc marks at the terminals for the generator cable.

Result:
Result Proceed to
The terminals are connected securely and there are no contact problems. There are no arc marks. A
The terminals are not connected securely and there is a contact problem. There are arc marks. B
The terminals are not connected securely and there is a contact problem. There are no arc marks. C
The terminals are connected securely and there are no contact problems. There are arc marks. B



f.

Reconnect the motor cable.


g.

Reinstall the inverter with converter assembly.



A

4.CHECK MOTOR CABLE (FOR MG2)

B

REPLACE MALFUNCTIONING PARTS

C

CONNECT SECURELY

4.CHECK MOTOR CABLE (FOR MG2)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Remove the inverter with converter assembly.


c.

Remove the motor cable.


d.

Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

NOTICE:

Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.


A407602C03
1.75,0.615 2.042,0.865 0.292,0.25 5.135,0.615 5.427,0.865 0.292,0.25 2.979,1.979 3.094,2.219 true 1.25,1.458 1.073,2.188 true 1.656,1.458 1.604,2.177 true 1.917,1.458 2.031,2.156 true 5.219,1.24 5.385,2.135 true 4.979,1.24 5,2.115 true 4.729,1.24 4.531,2.115 true 6.542,1.521 6.656,1.76 true 0.229,0.156 0.542,0.354 0.313,0.198 10 false *a 1.833,0.677 2.146,0.875 0.313,0.198 10 false E2 5.229,0.677 5.542,0.875 0.313,0.198 10 false E1 3.167,2.167 3.479,2.365 0.313,0.198 10 false *1 1.01,2.229 1.323,2.427 0.313,0.198 10 false W 4.479,2.167 4.792,2.365 0.313,0.198 10 false W 1.563,2.229 1.875,2.427 0.313,0.198 10 false U 4.958,2.156 5.271,2.354 0.313,0.198 10 false U 1.99,2.229 2.302,2.427 0.313,0.198 10 false V 5.365,2.177 5.677,2.375 0.313,0.198 10 false V 6.74,1.719 7.052,1.917 0.313,0.198 10 false *1
*1 Shielded Ground - -
*a Motor Cable - -


Standard Resistance:
Tester Connection Condition Specified Condition
E2-1 (W) or E1-1 (W) - Shield ground Power switch off 100 MΩ or higher
E2-2 (U) or E1-2 (U) - Shield ground Power switch off 100 MΩ or higher
E2-3 (V) or E1-3 (V) - Shield ground Power switch off 100 MΩ or higher


NOTICE:

Wrap the terminal of the motor cable with insulating tape to prevent them from coming into contact with body ground.



e.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
E2-1 (W) - E1-1 (W) Power switch off Below 1 Ω
E2-2 (U) - E1-2 (U) Power switch off Below 1 Ω
E2-3 (V) - E1-3 (V) Power switch off Below 1 Ω
E2-1 (W) - E1-2 (U) Power switch off 100 MΩ or higher
E2-2 (U) - E1-3 (V) Power switch off 100 MΩ or higher
E2-3 (V) - E1-1 (W) Power switch off 100 MΩ or higher



f.

Reinstall the motor cable.


g.

Reinstall the inverter with converter assembly.


Result:
Proceed to
OK
NG



OK

NG