HYBRID / BATTERY CONTROL  HYBRID CONTROL SYSTEM(for NICKEL METAL HYDRIDE BATTERY)  P0AFC62  Hybrid/EV Battery Sensor Module Signal Compare Failure  P0B3B14  Hybrid/EV Battery Voltage Sensor "A" Circuit Short to Ground or Open  P0B4014  Hybrid/EV Battery Voltage Sensor "B" Circuit Short to Ground or Open  P0B4514  Hybrid/EV Battery Voltage Sensor "C" Circuit Short to Ground or Open  P0B4A14  Hybrid/EV Battery Voltage Sensor "D" Circuit Short to Ground or Open  P0B4F14  Hybrid/EV Battery Voltage Sensor "E" Circuit Short to Ground or Open  P0B5414  Hybrid/EV Battery Voltage Sensor "F" Circuit Short to Ground or Open  P0B5914  Hybrid/EV Battery Voltage Sensor "G" Circuit Short to Ground or Open  P0B5E14  Hybrid/EV Battery Voltage Sensor "H" Circuit Short to Ground or Open  P0B6314  Hybrid/EV Battery Voltage Sensor "I" Circuit Short to Ground or Open  P0B6814  Hybrid/EV Battery Voltage Sensor "J" Circuit Short to Ground or Open  P0B6D14  Hybrid/EV Battery Voltage Sensor "K" Circuit Short to Ground or Open  P0B7214  Hybrid/EV Battery Voltage Sensor "L" Circuit Short to Ground or Open  P308A13  Hybrid/EV Battery Voltage Sensor All Circuit Open  


DESCRIPTION

Refer to the description for DTC P1AC000.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM (for NICKEL METAL HYDRIDE BATTERY)>P1AC000

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate
P0AFC62 Hybrid/EV Battery Sensor Module Signal Compare Failure The difference between the voltage output by detection circuit C and the total of the voltage output by detection circuits A and B exceeds a threshold.
HINT: The battery voltage sensor uses 3 voltage detection circuits (A, B and C) to detect the voltage of the battery blocks.
(1 trip detection logic)
·

Battery voltage sensor

·

HV battery


Comes on Master Warning Light:
Comes on
P0B3B14 Hybrid/EV Battery Voltage Sensor "A" Circuit Short to Ground or Open The battery block voltage detection line has a malfunction and any of the battery block voltages become lower than the specified value (open).
(1 trip detection logic)
·

Battery voltage sensor

·

HV battery


Comes on Master Warning Light:
Comes on
P0B4014 Hybrid/EV Battery Voltage Sensor "B" Circuit Short to Ground or Open The battery block voltage detection line has a malfunction and any of the battery block voltages become lower than the specified value (open).
(1 trip detection logic)
·

Battery voltage sensor

·

HV battery


Comes on Master Warning Light:
Comes on
P0B4514 Hybrid/EV Battery Voltage Sensor "C" Circuit Short to Ground or Open The battery block voltage detection line has a malfunction and any of the battery block voltages become lower than the specified value (open).
(1 trip detection logic)
·

Battery voltage sensor

·

HV battery


Comes on Master Warning Light:
Comes on
P0B4A14 Hybrid/EV Battery Voltage Sensor "D" Circuit Short to Ground or Open The battery block voltage detection line has a malfunction and any of the battery block voltages become lower than the specified value (open).
(1 trip detection logic)
·

Battery voltage sensor

·

HV battery


Comes on Master Warning Light:
Comes on
P0B4F14 Hybrid/EV Battery Voltage Sensor "E" Circuit Short to Ground or Open The battery block voltage detection line has a malfunction and any of the battery block voltages become lower than the specified value (open).
(1 trip detection logic)
·

Battery voltage sensor

·

HV battery


Comes on Master Warning Light:
Comes on
P0B5414 Hybrid/EV Battery Voltage Sensor "F" Circuit Short to Ground or Open The battery block voltage detection line has a malfunction and any of the battery block voltages become lower than the specified value (open).
(1 trip detection logic)
·

Battery voltage sensor

·

HV battery


Comes on Master Warning Light:
Comes on
P0B5914 Hybrid/EV Battery Voltage Sensor "G" Circuit Short to Ground or Open The battery block voltage detection line has a malfunction and any of the battery block voltages become lower than the specified value (open).
(1 trip detection logic)
·

Battery voltage sensor

·

HV battery


Comes on Master Warning Light:
Comes on
P0B5E14 Hybrid/EV Battery Voltage Sensor "H" Circuit Short to Ground or Open The battery block voltage detection line has a malfunction and any of the battery block voltages become lower than the specified value (open).
(1 trip detection logic)
·

Battery voltage sensor

·

HV battery


Comes on Master Warning Light:
Comes on
P0B6314 Hybrid/EV Battery Voltage Sensor "I" Circuit Short to Ground or Open The battery block voltage detection line has a malfunction and any of the battery block voltages become lower than the specified value (open).
(1 trip detection logic)
·

Battery voltage sensor

·

HV battery


Comes on Master Warning Light:
Comes on
P0B6814 Hybrid/EV Battery Voltage Sensor "J" Circuit Short to Ground or Open The battery block voltage detection line has a malfunction and any of the battery block voltages become lower than the specified value (open).
(1 trip detection logic)
·

Battery voltage sensor

·

HV battery


Comes on Master Warning Light:
Comes on
P0B6D14 Hybrid/EV Battery Voltage Sensor "K" Circuit Short to Ground or Open The battery block voltage detection line has a malfunction and any of the battery block voltages become lower than the specified value (open).
(1 trip detection logic)
·

Battery voltage sensor

·

HV battery


Comes on Master Warning Light:
Comes on
P0B7214 Hybrid/EV Battery Voltage Sensor "L" Circuit Short to Ground or Open The battery block voltage detection line has a malfunction and any of the battery block voltages become lower than the specified value (open).
(1 trip detection logic)
·

Battery voltage sensor

·

HV battery


Comes on Master Warning Light:
Comes on
P308A13 Hybrid/EV Battery Voltage Sensor All Circuit Open The battery block voltage detection line is open (all blocks) or all battery block voltages become lower than the specified value (possibility of open or loosely connected connector).
(1 trip detection logic)
·

Battery voltage sensor

·

HV battery


Comes on Master Warning Light:
Comes on

HINT:

Hybrid Battery Block 1 to 11 Voltage values smaller than 2.0 V may not be shown in the Data List because a fail-safe value is substituted.


Related Data List
DTC No. Data List
P0AFC62 Hybrid Battery Block 1 to 11 Voltage*1
P0B3B14
P0B4014
P0B4514
P0B4A14
P0B4F14
P0B5414
P0B5914
P0B5E14
P0B6314
P0B6814
P0B6D14
P0B7214
P308A13
·

Hybrid Battery Voltage

·

Hybrid Battery Block 1 to 11 Voltage*1



HINT:
·

*1: Under normal conditions, the values of Hybrid Battery Block 1, 2, 9, 10 and 11 Voltage will be approximately 16 V and Hybrid Battery Block 3, 4, 5, 6, 7 and 8 Voltage will be approximately 32 V.

·

If there is a short or open in a battery block voltage detection line, the value of Hybrid Battery Block Voltage for the corresponding battery block will be lower than 8 V.



CONFIRMATION DRIVING PATTERN

HINT:

After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM (for NICKEL METAL HYDRIDE BATTERY)>UTILITY


1.

Connect the GTS to the DLC3.

2.

Turn the power switch on (IG) and turn the GTS on.

3.

Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).

4.

Turn the power switch off and wait for 2 minutes or more.

5.

Turn the power switch on (IG) and turn the GTS on.

6.

With power switch on (IG) and wait for 20 seconds or more.

7.

Enter the following menus: Powertrain / Hybrid Control / Utility / All Readiness.

8.

Check the DTC judgment result.

HINT:
·

If the judgment result shows NORMAL, the system is normal.

·

If the judgment result shows ABNORMAL, the system has a malfunction.

·

If the judgment result shows INCOMPLETE or N/A, perform driving pattern again.




CAUTION / NOTICE / HINT

CAUTION:
·
A340358

Before the following operations are conducted, take precautions to prevent electric shock by turning the power switch off, wearing insulated gloves, and removing the service plug grip from HV battery.

-

Inspecting the high-voltage system

-

Disconnecting the low voltage connector of the inverter with converter assembly

-

Disconnecting the low voltage connector of the HV battery


·
A357588

To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.

·
A358042

After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

·
A357589C02
1.573,0.74 2.021,0.427 true 2.094,0.344 2.354,0.51 0.26,0.167 10 false *a
*a Without waiting for 10 minutes


After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM (for NICKEL METAL HYDRIDE BATTERY)>PRECAUTION

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.


·

Make sure to insulate the high-voltage connectors and terminals of the HV battery with insulating tape after removing it.

If the HV battery stored without insulating the connectors and terminals, electric shock or fire may result.

·
A358021C02
0.531,4.146 0.844,4.344 0.313,0.198 10 false *a 2.74,4.146 3.052,4.344 0.313,0.198 10 false *b
*a Dealer
*b Battery Collection Agent


When disposing of an HV battery, make sure to return it through an authorized collection agent who is capable of handling it safely. If the HV battery is returned via the manufacturer specified route, it will be returned properly and in a safe manner by an authorized collection agent.

-

Accidents such as electric shock may result if the HV battery is disposed of improperly or abandoned. Therefore, make sure to return all HV batteries through an authorized collection agent.


·
A358020

After removing the HV battery, keep it away from water. Exposure to water may cause the HV battery to produce heat, resulting in a fire.



NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION


PROCEDURE

1.CHECK DTC OUTPUT (HYBRID CONTROL)
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.


d.

Check and record any HV system DTCs and freeze frame data.


e.

Read output DTCs.

Powertrain > Hybrid Control > Trouble Codes
50001 397
Result:
Result Proceed to
"P0AFC00, P0AFC96 or P308A12" is not output. A
"P0AFC00, P0AFC96 or P308A12" is also output. B



f.

Turn the power switch off.



A

2.CHECK CONNECTOR CONNECTION CONDITION (BATTERY VOLTAGE SENSOR CONNECTOR)

B

2.CHECK CONNECTOR CONNECTION CONDITION (BATTERY VOLTAGE SENSOR CONNECTOR)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.




c.
A406079

Check the connections of the battery voltage sensor connector.

Click hereGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>ELECTRONIC CIRCUIT INSPECTION PROCEDURE

OK:

The connector is connected securely and there are no contact problems.



d.

Remove the No. 1 HV battery shield panel.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>BATTERY VOLTAGE SENSOR>REMOVAL


e.
A485384

Check the connections of the battery voltage sensor connector.

Click hereGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>ELECTRONIC CIRCUIT INSPECTION PROCEDURE

OK:

The connector is connected securely and there are no contact problems.



Result:
Proceed to
OK
NG


f.

Install the No. 1 HV battery shield panel.


g.

Install the No. 1 hybrid battery exhaust duct.



OK

3.REPLACE BATTERY VOLTAGE SENSOR

NG

CONNECT SECURELY

3.REPLACE BATTERY VOLTAGE SENSOR

NEXT

4.CLEAR DTC (HYBRID CONTROL)
4.CLEAR DTC (HYBRID CONTROL)
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.


d.

Clear the DTCs and freeze frame data.

Powertrain > Hybrid Control > Clear DTCs
50002 397

e.

Turn the power switch off and wait for 2 minutes or more.


Result:
Proceed to
NEXT



NEXT

5.RECONFIRM DTC OUTPUT (HYBRID CONTROL)
5.RECONFIRM DTC OUTPUT (HYBRID CONTROL)
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG) and wait for 20 seconds or more.


c.

Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.


d.

Read output DTCs.

Powertrain > Hybrid Control > Trouble Codes
50001 397
Result:
Result Proceed to
Hybrid battery voltage sensor circuit DTCs for this diagnostic procedure are not output. A
Hybrid battery voltage sensor circuit DTCs for this diagnostic procedure are output. B



e.

Turn the power switch off.



A

END

B