Refer to DTC P019011.
Click hereEngine / Hybrid System>A25A-FXS (ENGINE CONTROL)>SFI SYSTEM (w/ Canister Pump Module)>P019011
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Memory | Note |
|---|---|---|---|---|---|---|
| P019015 | Fuel Rail Pressure Sensor "A" Circuit Short to Battery or Open | The fuel pressure sensor (for high pressure side) output voltage is higher than 4.9 V for 3 seconds or more (1 trip detection logic). | ·
Open or short in fuel pressure sensor (for high pressure side) circuit ·
Fuel pressure sensor (for high pressure side) ·
ECM |
Comes on | DTC stored | SAE Code: P0193 |
When this DTC is output, check the fuel pressure (for high pressure side) in the Data List. Enter the following menus: Powertrain / Engine / Data List / Fuel Pressure (High).
| DTC No. | Fuel Pressure (High) | Malfunction |
|---|---|---|
| P019015 | Approximately 33000 kPag or higher | ·
Short in VCPR to PR circuit ·
Open in PR circuit ·
Open in EPR circuit |
If the Data List values is normal it may be due to a temporary recovery from the malfunction condition. Check for intermittent problems.
This DTC is stored if the fuel pressure sensor (for high pressure side) output voltage is out of the standard range due to an open or short in the sensor circuit.
Example:
If the fuel pressure sensor (for high pressure side) output voltage is higher than 4.9 V for 3 seconds or more, the ECM will illuminate the MIL and store this DTC.
| Required Sensors/Components | Fuel pressure sensor (for high pressure side) |
| Frequency of Operation | Continuous |
Connect the GTS to the DLC3.
Turn the Power switch on (IG).
Turn the GTS on.
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the power switch off and wait for at least 30 seconds.
Turn the Power switch on (IG).
Turn the GTS on.
Put the engine in Inspection Mode (Maintenance Mode).
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>INSPECTION MODE PROCEDURE
Start the engine [A].
Idle the engine for 10 seconds [B].
Enter the following menus: Powertrain / Engine / Trouble Codes [C].
Read the pending DTCs.
If a pending DTC is output, the system is malfunctioning.
If a pending DTC is not output, perform the following procedure.
Enter the following menus: Powertrain / Engine / Utility / All Readiness.
Input the DTC: P019015.
Check the DTC judgment result.
| GTS Display | Description |
|---|---|
| NORMAL | ·
DTC judgment completed ·
System normal |
| ABNORMAL | ·
DTC judgment completed ·
System abnormal |
| INCOMPLETE | ·
DTC judgment not completed ·
Perform driving pattern after confirming DTC enabling conditions |
If the judgment result is NORMAL, the system is normal.
If the judgment result is ABNORMAL, the system has a malfunction.
If the judgment result is INCOMPLETE, perform steps [B] through [C] again.
Refer to DTC P019011.
Click hereEngine / Hybrid System>A25A-FXS (ENGINE CONTROL)>SFI SYSTEM (w/ Canister Pump Module)>P019011
Vehicle Control History may be stored in the hybrid vehicle control ECU assembly if the engine is malfunctioning. Certain vehicle condition information is recorded when Vehicle Control History is stored. Reading the vehicle conditions recorded in both the freeze frame data and Vehicle Control History can be useful for troubleshooting.
(Select Powertrain in Health Check and then check the time stamp data.)
If any "Engine Malfunction" Vehicle Control History item has been stored in the hybrid vehicle control ECU assembly, make sure to clear it. However, as all Vehicle Control History items are cleared simultaneously, if any Vehicle Control History items other than "Engine Malfunction" are stored, make sure to perform any troubleshooting for them before clearing Vehicle Control History.
Read Freeze Frame Data using the GTS. The ECM records vehicle and driving condition information as Freeze Frame Data the moment a DTC is stored. When troubleshooting, Freeze Frame Data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air fuel ratio was lean or rich, and other data from the time the malfunction occurred.
| *a | Front view of wire harness connector
(to Fuel Pressure Sensor (for High Pressure Side)) |
Make sure that the connector is properly connected. If it is not, securely connect it and check for DTCs again.
Disconnect the fuel pressure sensor (for high pressure side) connector.
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| d1-1 (VC) - d1-2 (E2) | Power switch on (IG) | 4.75 to 5.25 V |
| d1-3 (PR) - d1-2 (E2) | Power switch on (IG) | 3.0 to 5.25 V |
Turn the power switch off and wait for at least 30 seconds.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| d1-2 (E2) - Body ground | Power switch off | Below 1 Ω |
| d1-1 (VC) - d1-3 (PR) | Power switch off | 171 to 189 kΩ |
Perform "Inspection After Repair" after replacing the fuel pressure sensor (for high pressure side).
Click hereEngine / Hybrid System>A25A-FXS (ENGINE CONTROL)>SFI SYSTEM (w/ Canister Pump Module)>INITIALIZATION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the fuel pressure sensor (for high pressure side) connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| d1-3 (PR) - C100-97 (PR) | Always | Below 1 Ω |
| d1-2 (E2) - C100-96 (EPR) | Always | Below 1 Ω |
| d1-3 (PR) or C100-97 (PR) - Other terminals | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG