DESCRIPTION

If warm air blows from the registers regardless of the temperature setting of the air conditioning system, the following factors may be the cause.

Symptom Factor
No cool air comes out
(Blower control is normal)
·

Compressor with motor assembly malfunction

·

Refrigerant pressure is extremely high or low

·

Refrigerant volume (low)

·

Clogged cooler condenser assembly fins

·

Cooling fan system malfunction

·

Mechanical locking of damper and damper link

·

No. 1 cooler thermistor malfunction

·

High inlet air temperature



PROCEDURE

1.CONFIRM MODEL
Result:
Result Proceed to
for 8 Inch Display A
except 8 Inch Display B



A

2.CHECK SWITCH INDICATOR

B

3.CHECK SWITCH INDICATOR
2.CHECK SWITCH INDICATOR
a.

Operate each switch on the air conditioning control panel (radio and display receiver assembly) and check that the switch indicators operate normally.

OK:

All switch indicators operate normally.



Result:
Proceed to
OK
NG



OK

4.PERFORM ACTIVE TEST USING GTS

NG

GO TO OTHER DIAGNOSIS PROCEDURE (Operation not Accepted Even If Air Conditioning Switch is Operated)

3.CHECK SWITCH INDICATOR
a.

Operate each switch on the air conditioning control assembly and check that the switch indicators operate normally.

OK:

All switch indicators operate normally.



Result:
Proceed to
OK
NG



OK

4.PERFORM ACTIVE TEST USING GTS

NG

GO TO OTHER DIAGNOSIS PROCEDURE (Operation not Accepted Even If Air Conditioning Switch is Operated)

4.PERFORM ACTIVE TEST USING GTS
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Turn the GTS on.


d.

Enter the following menus: Body Electrical / Air Conditioner / Active Test.


e.

Perform the Active Test according to the display on the GTS.

Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
Air Mix Servo Targ Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) pulse Min.: 128
Max.: 383
for LHD

Operates between 165 to 257 pulses


for RHD

Operates between 255 to 347 pulses


Air Mix Servo Targ Pulse(P) No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) pulse Min.: 128
Max.: 383
for LHD:

Operates between 255 to 347 pulses


for RHD:

Operates between 165 to 257 pulses


Rear Air Mix Servo Targ Pulse No. 3 air conditioning radiator damper servo sub-assembly pulse Min.: 128
Max.: 383
Operates between 165 to 257 pulses*

*: for 3 Zone Type


Body Electrical > Air Conditioner > Active Test
Tester Display
Air Mix Servo Targ Pulse(D)
50004 121 24
Body Electrical > Air Conditioner > Active Test
Tester Display
Air Mix Servo Targ Pulse(P)
50004 121 25
Body Electrical > Air Conditioner > Active Test
Tester Display
Rear Air Mix Servo Targ Pulse
50004 121 36
OK:

Each damper servo motor operates.



Result:
Proceed to
OK
NG



OK

INSPECT REFRIGERANT PRESSURE WITH MANIFOLD GAUGE SET

NG

GO TO DTC TROUBLESHOOTING PROCEDURE FOR MALFUNCTIONING DAMPER SERVO MOTOR