HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM  B1497  Communication Malfunction (Bus Ic)  


DESCRIPTION

The air conditioning harness assembly connects the air conditioning amplifier assembly and the servo motors. The air conditioning amplifier assembly supplies power and sends operation instructions to each servo motor through the air conditioning harness assembly. Each servo motor sends damper position information to the air conditioning amplifier assembly.

DTC No. Detection Item DTC Detection Condition Trouble Area Memory
B1497 Communication Malfunction (Bus Ic) Error or open in communication line
·

Air conditioning harness assembly

·

No. 1 air conditioning radiator damper servo sub-assembly

·

No. 2 air conditioning radiator damper servo sub-assembly

·

No. 3 air conditioning radiator damper servo sub-assembly*1

·

No. 4 air conditioning radiator damper servo sub-assembly*2

·

Air conditioning amplifier assembly


Memorized
(10 sec. or more)*3

*1: for 3 Zone Type

*2: for LHD (for 3 Zone Type) or RHD

*3: The air conditioning amplifier assembly stores this DTC if the malfunction has occurred for the period of time indicated in the brackets.


WIRING DIAGRAM

for LHD


E378663E08
6.625,0.365 6.938,0.563 0.313,0.198 10 false +B 5.198,1.927 6.781,2.281 1.583,0.354 10 false Air Conditioning Amplifier Assembly 5.177,3.708 7.115,4.156 1.938,0.448 10 false No. 2 Air Conditioning Radiator Damper Servo Sub-assembly 5.177,5.542 7.125,5.896 1.948,0.354 10 false No. 3 Air Conditioning Radiator Damper Servo Sub-assembly*1 5.177,7.354 7.094,7.708 1.917,0.354 10 false No. 4 Air Conditioning Radiator Damper Servo Sub-assembly*1 3.25,7.99 5.458,8.198 2.208,0.208 10 false Air Conditioning Harness Assembly 0.813,6.292 2.698,6.667 1.885,0.375 10 false No. 1 Air Conditioning Radiator Damper Servo Sub-assembly 3.438,0.396 3.594,0.604 0.156,0.208 10 false 1 0.688,8.458 2.271,8.646 1.583,0.188 10 false : LIN Communication Line 3.448,0.802 3.625,1.01 0.177,0.208 10 false 2 5.344,0.792 5.5,1 0.156,0.208 10 false 3 5.354,0.396 5.531,0.604 0.177,0.208 10 false 4 3.448,1.271 3.635,1.479 0.188,0.208 10 false 3 0.813,6.115 1.052,6.323 0.24,0.208 10 false A 2.563,2.615 2.771,2.802 0.208,0.188 10 false IC 0.594,1.521 1.917,1.708 1.323,0.188 10 false Driver Side Air Mix 0.24,3.427 2.177,3.615 1.938,0.188 10 false Front Passenger Side Mode*1 0.969,3.708 1.594,3.938 0.625,0.229 10 false Mode*2 0.219,5.354 2.104,5.594 1.885,0.24 10 false Front Passenger Side Air Mix 3.135,0.948 3.625,1.156 0.49,0.208 10 false LIN 3.052,1.365 3.542,1.573 0.49,0.208 10 false GND 5.521,0.396 6.01,0.604 0.49,0.208 10 false B BUS 5.521,0.854 6.01,1.063 0.49,0.208 10 false BUS 5.521,1.271 6.01,1.479 0.49,0.208 10 false BUS G 6.75,0.948 6.948,1.146 0.198,0.198 10 false IC 3.146,0.49 3.438,0.698 0.292,0.208 10 false +B 5.208,1.75 5.698,1.958 0.49,0.208 10 false z11 4.833,3.052 5.042,3.24 0.208,0.188 10 false IC 4.833,4.885 5.042,5.073 0.208,0.188 10 false IC 4.833,6.719 5.042,6.906 0.208,0.188 10 false IC 5.354,1.26 5.469,1.469 0.115,0.208 10 false 2 0.281,7.698 1.906,7.958 1.625,0.26 10 false *2: except 3 Zone Type 0.281,7.365 2.01,7.583 1.729,0.219 10 false *1: for 3 Zone Type


for RHD


E378725E12
0.177,1.5 2.115,1.698 1.938,0.198 10 false Front Passenger Side Air Mix 0.625,3.427 1.813,3.646 1.188,0.219 10 false Driver Side Mode 0.563,5.354 1.896,5.573 1.333,0.219 10 false Driver Side Air Mix 0.781,8.427 2.406,8.625 1.625,0.198 10 false : LIN Communication Line 3.292,7.958 5.531,8.167 2.24,0.208 10 false Air Conditioning Harness Assembly 5.198,6.094 7.115,6.458 1.917,0.365 10 false No. 4 Air Conditioning Radiator Damper Servo Sub-assembly 5.177,3.885 7.094,4.25 1.917,0.365 10 false No. 2 Air Conditioning Radiator Damper Servo Sub-assembly 5.219,1.906 6.771,2.26 1.552,0.354 10 false Air Conditioning Amplifier Assembly 6.625,0.365 6.865,0.542 0.24,0.177 10 false +B 6.771,0.938 7.01,1.115 0.24,0.177 10 false IC 5.219,1.74 5.521,1.927 0.302,0.188 10 false z11 5.333,0.375 5.49,0.542 0.156,0.167 10 false 4 5.333,0.802 5.49,0.969 0.156,0.167 10 false 3 5.344,1.25 5.5,1.417 0.156,0.167 10 false 2 5.542,0.375 6.083,0.552 0.542,0.177 10 false B BUS 5.542,0.802 6.083,0.979 0.542,0.177 10 false BUS 5.552,1.25 6.094,1.427 0.542,0.177 10 false BUS G 3.146,0.479 3.396,0.656 0.25,0.177 10 false +B 3.052,1.375 3.385,1.542 0.333,0.167 10 false GND 3.115,0.938 3.448,1.104 0.333,0.167 10 false LIN 3.448,1.26 3.625,1.427 0.177,0.167 10 false 3 3.438,0.375 3.615,0.542 0.177,0.167 10 false 1 3.448,0.813 3.625,0.979 0.177,0.167 10 false 2 2.563,2.625 2.76,2.792 0.198,0.167 10 false IC 4.833,3.167 5.031,3.333 0.198,0.167 10 false IC 4.833,5.365 5.031,5.531 0.198,0.167 10 false IC 0.708,6.24 2.615,6.688 1.906,0.448 10 false No. 1 Air Conditioning Radiator Damper Servo Sub-assembly 0.708,6.073 0.969,6.26 0.26,0.188 10 false A


PROCEDURE

1.CONFIRM MODEL
a.

Choose the model to be inspected.


Result:
Result Proceed to
for LHD (for 3 Zone Type) A
for LHD (except 3 Zone Type) B
for RHD C



A

2.PERFORM ACTIVE TEST USING GTS

B

7.PERFORM ACTIVE TEST USING GTS

C

12.PERFORM ACTIVE TEST USING GTS
2.PERFORM ACTIVE TEST USING GTS
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Turn the GTS on.


d.

Enter the following menus: Body Electrical / Air Conditioner / Active test.


e.

Perform the Active Test according to the display on the GTS.

Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
Air Mix Servo Targ Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) pulse Min.: 128
Max.: 383
Operates between 165 to 257 pulses
Air Outlet Servo Pulse (D) No. 4 air conditioning radiator damper servo sub-assembly pulse Min.: 128
Max.: 383
Operates between 164 to 271 pulses
Rear Air Mix Servo Targ Pulse No. 3 air conditioning radiator damper servo sub-assembly pulse Min.: 128
Max.: 383
Operates between 165 to 257 pulses
A/O Servo Pulse(Rr D) No. 2 air conditioning radiator damper servo sub-assembly pulse Min.: 128
Max.: 383
Operates between 158 to 260 pulses
Body Electrical > Air Conditioner > Active Test
Tester Display
Air Mix Servo Targ Pulse(D)
50004 121 24
Body Electrical > Air Conditioner > Active Test
Tester Display
Air Outlet Servo Pulse (D)
50004 121 26
Body Electrical > Air Conditioner > Active Test
Tester Display
Rear Air Mix Servo Targ Pulse
50004 121 36
Body Electrical > Air Conditioner > Active Test
Tester Display
A/O Servo Pulse(Rr D)
50004 121 56

Result:
Result Proceed to
All of the damper servo motors are malfunctioning A
One of the damper servo motors is malfunctioning B



A

3.PERFORM ACTIVE TEST USING GTS

B

5.PERFORM ACTIVE TEST USING GTS
3.PERFORM ACTIVE TEST USING GTS
a.

Disconnect the No. 1 air conditioning radiator damper servo sub-assembly connector.


b.

Connect the GTS to the DLC3.


c.

Turn the power switch on (IG).


d.

Turn the GTS on.


e.

Enter the following menus: Body Electrical / Air Conditioner / Active test.


f.

Perform the Active Test according to the display on the GTS.

Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
A/O Servo Pulse(Rr D) No. 2 air conditioning radiator damper servo sub-assembly pulse Min.: 128
Max.: 383
Operates between 158 to 260 pulses
Body Electrical > Air Conditioner > Active Test
Tester Display
A/O Servo Pulse(Rr D)
50004 121 56
OK:

The damper servo motor operates smoothly.



Result:
Proceed to
OK
NG



OK

REPLACE NO. 1 AIR CONDITIONING RADIATOR DAMPER SERVO SUB-ASSEMBLY

NG

4.INSPECT AIR CONDITIONING AMPLIFIER ASSEMBLY
4.INSPECT AIR CONDITIONING AMPLIFIER ASSEMBLY
E334625C27
2.802,0.333 3.135,0.542 0.333,0.208 2.979,1.26 2.26,2.073 true 3.094,1.271 2.688,2.24 true 2.906,1.188 1.917,0.573 true 0.198,0.135 0.51,0.333 0.313,0.198 10 false *a 1.948,2.094 2.406,2.292 0.458,0.198 10 false BUS 2.406,2.271 3.021,2.521 0.615,0.25 10 false BUS G 0.417,3.938 0.875,4.135 0.458,0.198 10 false GND 2.865,0.354 3.177,0.552 0.313,0.198 10 false z11 1.677,0.385 2.177,0.625 0.5,0.24 10 false B BUS
*a Component with harness connected
(Air Conditioning Amplifier Assembly)


NOTICE:

When inspecting the air conditioning amplifier assembly, do not bring the tester probes too close to each other as a short circuit may occur.


a.

Disconnect the z11 air conditioning amplifier assembly connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
z11-2 (BUS G) - Body ground Always Below 1 Ω



c.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
z11-4 (B BUS) - Body ground Power switch on (IG) 11 to 14 V



d.

Turn the power switch on (IG).


e.

Using an oscilloscope, check the waveform.

Item Content
Terminal No. z11-3 (BUS) - z11-2 (BUS G)
Tool Setting 2 V/DIV., 2 ms./DIV.
Condition Power switch on (IG)

OK:

Waveform is similar to that shown in the illustration.


HINT:

The waveform varies with the blower speed.



Result:
Proceed to
OK
NG



OK

REPLACE AIR CONDITIONING HARNESS ASSEMBLY

NG

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

5.PERFORM ACTIVE TEST USING GTS
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Turn the GTS on.


d.

Enter the following menus: Body Electrical / Air Conditioner / Active test.


e.

Perform the Active Test according to the display on the GTS.

Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
Air Mix Servo Targ Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) pulse Min.: 128
Max.: 383
Operates between 165 to 257 pulses
Air Outlet Servo Pulse (D) No. 4 air conditioning radiator damper servo sub-assembly pulse Min.: 128
Max.: 383
Operates between 164 to 271 pulses
Rear Air Mix Servo Targ Pulse No. 3 air conditioning radiator damper servo sub-assembly pulse Min.: 128
Max.: 383
Operates between 165 to 257 pulses
A/O Servo Pulse(Rr D) No. 2 air conditioning radiator damper servo sub-assembly pulse Min.: 128
Max.: 383
Operates between 158 to 260 pulses
Body Electrical > Air Conditioner > Active Test
Tester Display
Air Mix Servo Targ Pulse(D)
50004 121 24
Body Electrical > Air Conditioner > Active Test
Tester Display
Air Outlet Servo Pulse (D)
50004 121 26
Body Electrical > Air Conditioner > Active Test
Tester Display
Rear Air Mix Servo Targ Pulse
50004 121 36
Body Electrical > Air Conditioner > Active Test
Tester Display
A/O Servo Pulse(Rr D)
50004 121 56

Result:
Result Proceed to
Only the No. 1 air conditioning radiator damper servo sub-assembly does not operate A
Only the No. 2 air conditioning radiator damper servo sub-assembly does not operate B
Only the No. 3 air conditioning radiator damper servo sub-assembly does not operate
Only the No. 4 air conditioning radiator damper servo sub-assembly does not operate
Only the No. 4 air conditioning radiator damper servo sub-assembly operates



A

6.INSPECT AIR CONDITIONING HARNESS ASSEMBLY (AIR CONDITIONING AMPLIFIER ASSEMBLY - NO. 1 AIR CONDITIONING RADIATOR DAMPER SERVO SUB-ASSEMBLY)

B

REPLACE AIR CONDITIONING HARNESS ASSEMBLY

6.INSPECT AIR CONDITIONING HARNESS ASSEMBLY (AIR CONDITIONING AMPLIFIER ASSEMBLY - NO. 1 AIR CONDITIONING RADIATOR DAMPER SERVO SUB-ASSEMBLY)
a.

Disconnect the z11 air conditioning amplifier assembly connector.


b.

Disconnect the No. 1 air conditioning radiator damper servo sub-assembly connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
z11-2 (BUS G) - A-3 (GND) Always Below 1 Ω
z11-3 (BUS) - A-2 (LIN) Always Below 1 Ω
z11-4 (B BUS) - A-1 (+B) Always Below 1 Ω



Result:
Proceed to
OK
NG



OK

REPLACE NO. 1 AIR CONDITIONING RADIATOR DAMPER SERVO SUB-ASSEMBLY

NG

REPLACE AIR CONDITIONING HARNESS ASSEMBLY

7.PERFORM ACTIVE TEST USING GTS
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Turn the GTS on.


d.

Enter the following menus: Body Electrical / Air Conditioner / Active test.


e.

Perform the Active Test according to the display on the GTS.

Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
Air Mix Servo Targ Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) pulse Min.: 128
Max.: 383
Operates between 165 to 257 pulses
A/O Servo Pulse(Rr D) No. 2 air conditioning radiator damper servo sub-assembly pulse Min.: 128
Max.: 383
Operates between 158 to 260 pulses
Body Electrical > Air Conditioner > Active Test
Tester Display
Air Mix Servo Targ Pulse(D)
50004 121 24
Body Electrical > Air Conditioner > Active Test
Tester Display
A/O Servo Pulse(Rr D)
50004 121 56

Result:
Result Proceed to
All of the damper servo motors are malfunctioning A
One of the damper servo motors is malfunctioning B



A

8.PERFORM ACTIVE TEST USING GTS

B

10.PERFORM ACTIVE TEST USING GTS
8.PERFORM ACTIVE TEST USING GTS
a.

Disconnect the No. 1 air conditioning radiator damper servo sub-assembly connector.


b.

Connect the GTS to the DLC3.


c.

Turn the power switch on (IG).


d.

Turn the GTS on.


e.

Enter the following menus: Body Electrical / Air Conditioner / Active test.


f.

Perform the Active Test according to the display on the GTS.

Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
A/O Servo Pulse(Rr D) No. 2 air conditioning radiator damper servo sub-assembly pulse Min.: 128
Max.: 383
Operates between 158 to 260 pulses
Body Electrical > Air Conditioner > Active Test
Tester Display
A/O Servo Pulse(Rr D)
50004 121 56
OK:

The damper servo motor operates smoothly.



Result:
Proceed to
OK
NG



OK

REPLACE NO. 1 AIR CONDITIONING RADIATOR DAMPER SERVO SUB-ASSEMBLY

NG

9.INSPECT AIR CONDITIONING AMPLIFIER ASSEMBLY
9.INSPECT AIR CONDITIONING AMPLIFIER ASSEMBLY
E334625C27
2.802,0.333 3.135,0.542 0.333,0.208 2.979,1.26 2.26,2.073 true 3.094,1.271 2.688,2.24 true 2.906,1.188 1.917,0.573 true 0.198,0.135 0.51,0.333 0.313,0.198 10 false *a 1.948,2.094 2.406,2.292 0.458,0.198 10 false BUS 2.406,2.271 3.021,2.521 0.615,0.25 10 false BUS G 0.417,3.938 0.875,4.135 0.458,0.198 10 false GND 2.865,0.354 3.177,0.552 0.313,0.198 10 false z11 1.677,0.385 2.177,0.625 0.5,0.24 10 false B BUS
*a Component with harness connected
(Air Conditioning Amplifier Assembly)


NOTICE:

When inspecting the air conditioning amplifier assembly, do not bring the tester probes too close to each other as a short circuit may occur.


a.

Disconnect the z11 air conditioning amplifier assembly connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
z11-2 (BUS G) - Body ground Always Below 1 Ω



c.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
z11-4 (B BUS) - Body ground Power switch on (IG) 11 to 14 V



d.

Turn the power switch on (IG).


e.

Using an oscilloscope, check the waveform.

Item Content
Terminal No. z11-3 (BUS) - z11-2 (BUS G)
Tool Setting 2 V/DIV., 2 ms./DIV.
Condition Power switch on (IG)

OK:

Waveform is similar to that shown in the illustration.


HINT:

The waveform varies with the blower speed.



Result:
Proceed to
OK
NG



OK

REPLACE AIR CONDITIONING HARNESS ASSEMBLY

NG

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

10.PERFORM ACTIVE TEST USING GTS
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Turn the GTS on.


d.

Enter the following menus: Body Electrical / Air Conditioner / Active test.


e.

Perform the Active Test according to the display on the GTS.

Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
Air Mix Servo Targ Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) pulse Min.: 128
Max.: 383
Operates between 165 to 257 pulses
A/O Servo Pulse(Rr D) No. 2 air conditioning radiator damper servo sub-assembly pulse Min.: 128
Max.: 383
Operates between 158 to 260 pulses
Body Electrical > Air Conditioner > Active Test
Tester Display
Air Mix Servo Targ Pulse(D)
50004 121 24
Body Electrical > Air Conditioner > Active Test
Tester Display
A/O Servo Pulse(Rr D)
50004 121 56

Result:
Result Proceed to
Only the No. 1 air conditioning radiator damper servo sub-assembly does not operate A
Only the No. 2 air conditioning radiator damper servo sub-assembly does not operate B



A

11.INSPECT AIR CONDITIONING HARNESS ASSEMBLY (AIR CONDITIONING AMPLIFIER ASSEMBLY - NO. 1 AIR CONDITIONING RADIATOR DAMPER SERVO SUB-ASSEMBLY)

B

REPLACE AIR CONDITIONING HARNESS ASSEMBLY

11.INSPECT AIR CONDITIONING HARNESS ASSEMBLY (AIR CONDITIONING AMPLIFIER ASSEMBLY - NO. 1 AIR CONDITIONING RADIATOR DAMPER SERVO SUB-ASSEMBLY)
a.

Disconnect the z11 air conditioning amplifier assembly connector.


b.

Disconnect the No. 1 air conditioning radiator damper servo sub-assembly connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
z11-2 (BUS G) - A-3 (GND) Always Below 1 Ω
z11-3 (BUS) - A-2 (LIN) Always Below 1 Ω
z11-4 (B BUS) - A-1 (+B) Always Below 1 Ω



Result:
Proceed to
OK
NG



OK

REPLACE NO. 1 AIR CONDITIONING RADIATOR DAMPER SERVO SUB-ASSEMBLY

NG

REPLACE AIR CONDITIONING HARNESS ASSEMBLY

12.PERFORM ACTIVE TEST USING GTS
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Turn the GTS on.


d.

Enter the following menus: Body Electrical / Air Conditioner / Active test.


e.

Perform the Active Test according to the display on the GTS.

Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
Air Mix Servo Targ Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) pulse Min.: 128
Max.: 383
Operates between 255 to 347 pulses
Air Outlet Servo Pulse (P) No. 4 air conditioning radiator damper servo sub-assembly pulse Min.: 128
Max.: 383
Operates between 164 to 271 pulses
A/O Servo Pulse(Rr D) No. 2 air conditioning radiator damper servo sub-assembly pulse Min.: 128
Max.: 383
Operates between 158 to 260 pulses
Body Electrical > Air Conditioner > Active Test
Tester Display
Air Mix Servo Targ Pulse(D)
50004 121 24
Body Electrical > Air Conditioner > Active Test
Tester Display
Air Outlet Servo Pulse (P)
50004 121 97
Body Electrical > Air Conditioner > Active Test
Tester Display
A/O Servo Pulse(Rr D)
50004 121 56

Result:
Result Proceed to
All of the damper servo motors are malfunctioning A
One of the damper servo motors is malfunctioning B



A

13.PERFORM ACTIVE TEST USING GTS

B

15.PERFORM ACTIVE TEST USING GTS
13.PERFORM ACTIVE TEST USING GTS
a.

Disconnect the No. 1 air conditioning radiator damper servo sub-assembly connector.


b.

Connect the GTS to the DLC3.


c.

Turn the power switch on (IG).


d.

Turn the GTS on.


e.

Enter the following menus: Body Electrical / Air Conditioner / Active test.


f.

Perform the Active Test according to the display on the GTS.

Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
A/O Servo Pulse(Rr D) No. 2 air conditioning radiator damper servo sub-assembly pulse Min.: 128
Max.: 383
Operates between 158 to 260 pulses
Body Electrical > Air Conditioner > Active Test
Tester Display
A/O Servo Pulse(Rr D)
50004 121 56
OK:

The damper servo motor operates smoothly.



Result:
Proceed to
OK
NG



OK

REPLACE NO. 1 AIR CONDITIONING RADIATOR DAMPER SERVO SUB-ASSEMBLY

NG

14.INSPECT AIR CONDITIONING AMPLIFIER ASSEMBLY
14.INSPECT AIR CONDITIONING AMPLIFIER ASSEMBLY
E334625C27
2.802,0.333 3.135,0.542 0.333,0.208 2.979,1.26 2.26,2.073 true 3.094,1.271 2.688,2.24 true 2.906,1.188 1.917,0.573 true 0.198,0.135 0.51,0.333 0.313,0.198 10 false *a 1.948,2.094 2.406,2.292 0.458,0.198 10 false BUS 2.406,2.271 3.021,2.521 0.615,0.25 10 false BUS G 0.417,3.938 0.875,4.135 0.458,0.198 10 false GND 2.865,0.354 3.177,0.552 0.313,0.198 10 false z11 1.677,0.385 2.177,0.625 0.5,0.24 10 false B BUS
*a Component with harness connected
(Air Conditioning Amplifier Assembly)


NOTICE:

When inspecting the air conditioning amplifier assembly, do not bring the tester probes too close to each other as a short circuit may occur.


a.

Disconnect the z11 air conditioning amplifier assembly connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
z11-2 (BUS G) - Body ground Always Below 1 Ω



c.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
z11-4 (B BUS) - Body ground Power switch on (IG) 11 to 14 V



d.

Turn the power switch on (IG).


e.

Using an oscilloscope, check the waveform.

Item Content
Terminal No. z11-3 (BUS) - z11-2 (BUS G)
Tool Setting 2 V/DIV., 2 ms./DIV.
Condition Power switch on (IG)

OK:

Waveform is similar to that shown in the illustration.


HINT:

The waveform varies with the blower speed.



Result:
Proceed to
OK
NG



OK

REPLACE AIR CONDITIONING HARNESS ASSEMBLY

NG

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

15.PERFORM ACTIVE TEST USING GTS
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Turn the GTS on.


d.

Enter the following menus: Body Electrical / Air Conditioner / Active test.


e.

Perform the Active Test according to the display on the GTS.

Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
Air Mix Servo Targ Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) pulse Min.: 128
Max.: 383
Operates between 255 to 347 pulses
Air Outlet Servo Pulse (P) No. 4 air conditioning radiator damper servo sub-assembly pulse Min.: 128
Max.: 383
Operates between 164 to 271 pulses
A/O Servo Pulse(Rr D) No. 2 air conditioning radiator damper servo sub-assembly pulse Min.: 128
Max.: 383
Operates between 158 to 260 pulses
Body Electrical > Air Conditioner > Active Test
Tester Display
Air Mix Servo Targ Pulse(D)
50004 121 24
Body Electrical > Air Conditioner > Active Test
Tester Display
Air Outlet Servo Pulse (P)
50004 121 97
Body Electrical > Air Conditioner > Active Test
Tester Display
A/O Servo Pulse(Rr D)
50004 121 56

Result:
Result Proceed to
Only the No. 1 air conditioning radiator damper servo sub-assembly does not operate A
Only the No. 2 air conditioning radiator damper servo sub-assembly does not operate B
Only the No. 4 air conditioning radiator damper servo sub-assembly does not operate
Only the No. 4 air conditioning radiator damper servo sub-assembly operates



A

16.INSPECT AIR CONDITIONING HARNESS ASSEMBLY (AIR CONDITIONING AMPLIFIER ASSEMBLY - NO. 1 AIR CONDITIONING RADIATOR DAMPER SERVO SUB-ASSEMBLY)

B

REPLACE AIR CONDITIONING HARNESS ASSEMBLY

16.INSPECT AIR CONDITIONING HARNESS ASSEMBLY (AIR CONDITIONING AMPLIFIER ASSEMBLY - NO. 1 AIR CONDITIONING RADIATOR DAMPER SERVO SUB-ASSEMBLY)
a.

Disconnect the z11 air conditioning amplifier assembly connector.


b.

Disconnect the No. 1 air conditioning radiator damper servo sub-assembly connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
z11-2 (BUS G) - A-3 (GND) Always Below 1 Ω
z11-3 (BUS) - A-2 (LIN) Always Below 1 Ω
z11-4 (B BUS) - A-1 (+B) Always Below 1 Ω



Result:
Proceed to
OK
NG



OK

REPLACE NO. 1 AIR CONDITIONING RADIATOR DAMPER SERVO SUB-ASSEMBLY

NG

REPLACE AIR CONDITIONING HARNESS ASSEMBLY