Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM (for NICKEL METAL HYDRIDE BATTERY) › 2019.02–2020.08
RM33C0E _51 Engine / Hybrid System _065433 HYBRID / BATTERY CONTROL _0331295 HYBRID CONTROL SYSTEM C

HYBRID / BATTERY CONTROL  HYBRID CONTROL SYSTEM  P0A8100  Hybrid/EV Battery Cooling Fan 1 Control Circuit High  P0A8115  Hybrid/EV Battery Cooling Fan 1 Circuit Short to Auxiliary Battery or Open  


DESCRIPTION

Refer to the description for DTC P0A8111.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM (for NICKEL METAL HYDRIDE BATTERY)>P0A8111

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate
P0A8100 Hybrid/EV Battery Cooling Fan 1 Control Circuit High Both of the following conditions are met:
·

The HV battery temperature is high and the hybrid battery cooling fan speed calculated based on the battery cooling blower assembly output frequency (FP0) is not within the target control speed range.

·

The HV battery temperature is high and the battery cooling blower assembly speed is excessively high when a speed below a certain level is requested.


(1 trip detection logic)
·

Battery cooling blower assembly

·

Battery voltage sensor


Comes on Master Warning Light:
Comes on
P0A8115 Hybrid/EV Battery Cooling Fan 1 Circuit Short to Auxiliary Battery or Open Both of the following conditions are met:
·

The speed calculated based on the battery cooling blower assembly output frequency (FP0) is not within the target control speed range.

·

The battery cooling blower assembly speed is excessively high when a speed below a certain level is requested.


(1 trip detection logic / 2 trip detection logic)
·

Battery cooling blower assembly

·

Battery voltage sensor


Comes on / Does not come on Master Warning Light:
Comes on

Related Data List
DTC No. Data List
P0A8100
·

Hybrid Battery Cooling Fan 1 Drive Request

·

Hybrid Battery Cooling Fan 1 Drive Status

·

Hybrid Battery Cooling Fan 1 Frequency


P0A8115

The following items can be helpful when performing repairs:

Data List
·

Hybrid Battery Temperature 1 to 3

·

BATT Voltage


HINT:
·

"Hybrid Battery Cooling Fan 1 Frequency" is detected when the battery cooling blower assembly is operating and its value changes in proportion to the battery cooling blower assembly speed.

·

If the battery cooling blower assembly speed is excessively high, this DTC is stored.



CONFIRMATION DRIVING PATTERN

HINT:

After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM (for NICKEL METAL HYDRIDE BATTERY)>UTILITY


1.

Connect the GTS to the DLC3.

2.

Turn the power switch on (IG) and turn the GTS on.

3.

Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).

4.

Turn the power switch off and wait for 2 minutes or more.

5.

Turn the power switch on (IG) and turn the GTS on.

6.

Enter the following menus: Powertrain / Hybrid Control / Active Test / Control the Hybrid Battery Cooling Fan.

7.

Select fan mode 6 and operate the battery cooling blower assembly and wait for 60 seconds or more.

HINT:

Operation of the battery cooling blower assembly can be confirmed by checking if air is sucked into the air intake port of the intake duct or by operation sounds.


8.

Enter the following menus: Powertrain / Hybrid Control / Utility / All Readiness.

9.

Check the DTC judgment result.

HINT:
·

If the judgment result shows NORMAL, the system is normal.

·

If the judgment result shows ABNORMAL, the system has a malfunction.

·

If the judgment result shows INCOMPLETE or N/A, perform driving pattern again.




CAUTION / NOTICE / HINT

CAUTION:
·
A340358

Before the following operations are conducted, take precautions to prevent electric shock by turning the power switch off, wearing insulated gloves, and removing the service plug grip from HV battery.

-

Inspecting the high-voltage system

-

Disconnecting the low voltage connector of the inverter with converter assembly

-

Disconnecting the low voltage connector of the HV battery


·
A357588

To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.

·
A358042

After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

·
A357589C02
1.573,0.74 2.021,0.427 true 2.094,0.344 2.354,0.51 0.26,0.167 10 false *a
*a Without waiting for 10 minutes


After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM (for NICKEL METAL HYDRIDE BATTERY)>PRECAUTION

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.




NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION


PROCEDURE

1.CHECK DTC OUTPUT (HYBRID CONTROL)
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.


d.

Check for DTCs.

Powertrain > Hybrid Control > Trouble Codes
50001 397

Result:
Result Proceed to
P0AFC00 or P0AFC96 is not output. A
P0AFC00 or P0AFC96 is output. B


e.

Turn the power switch off.



A

2.CHECK BATTERY VOLTAGE SENSOR (FREQUENCY)

B

2.CHECK BATTERY VOLTAGE SENSOR (FREQUENCY)

OK

REPLACE BATTERY COOLING BLOWER ASSEMBLY

NG