MALFUNCTION DESCRIPTION
The hybrid vehicle control ECU assembly uses the inverter voltage to monitor the HV battery voltage and detect malfunctions.
The cause of this malfunction may be the following:
VL sensor malfunction
VH sensor malfunction
Battery ECU assembly malfunction
HV battery malfunction
The hybrid vehicle control ECU assembly uses the inverter voltage to monitor the HV battery voltage and detect malfunctions.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
| P31B300 | Hybrid/EV Battery Voltage High | The inverter voltage exceeds the threshold.
(1 trip detection logic) |
·
Inverter with converter assembly ·
Battery ECU assembly ·
No. 1 HV supply stack sub-assembly ·
No. 2 HV supply stack sub-assembly |
Comes on | Master Warning Light:
Comes on |
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Connect the GTS to the DLC3.
Turn the power switch on (IG) and turn the GTS on.
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the power switch off and wait for 2 minutes or more.
Turn the power switch on (IG) and turn the GTS on.
Turn the power switch on (READY) and wait for 30 seconds or more.
Enter the following menus: Powertrain / Hybrid Control / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE or N/A, perform driving pattern again.
Refer to the wiring diagram for the HV battery high-voltage line circuit.
Before the following operations are conducted, take precautions to prevent electric shock by turning the power switch off, wearing insulated gloves, and removing the service plug grip from HV battery.
Inspecting the high-voltage system
Disconnecting the low voltage connector of the inverter with converter assembly
Disconnecting the low voltage connector of the HV battery
To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.
After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
| *a | Without waiting for 10 minutes |
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
Make sure to insulate the high-voltage connectors and terminals of the HV battery with insulating tape after removing it.
If the HV battery stored without insulating the connectors and terminals, electric shock or fire may result.
| *a | Dealer |
| *b | Battery Collection Agent |
When disposing of an HV battery, make sure to return it through an authorized collection agent who is capable of handling it safely. If the HV battery is returned via the manufacturer specified route, it will be returned properly and in a safe manner by an authorized collection agent.
Before returning the HV battery, make sure to perform a recovery inspection.
Before returning the HV supply stack sub-assembly, make sure to perform a recovery inspection.
Make a note of the output DTCs as some of them may be necessary for recovery inspection of the HV battery and HV supply stack sub-assemblies.
After removing the HV battery, keep it away from water. Exposure to water may cause the HV battery to produce heat, resulting in a fire.
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control and Motor Generator / Trouble Codes.
Check for DTCs.
| Result | Proceed to |
|---|---|
| P31B300 only is output, or DTCs except the ones in the table below are also output. | A |
| DTCs of hybrid control system in the tables below are output. | B |
| DTCs of motor generator control system in the tables below are output. | C |
| Malfunction Content | System | Relevant DTC | |
|---|---|---|---|
| Sensor and actuator circuit malfunction | Hybrid control system | P0D2D1C | Drive Motor "A" Inverter Voltage Sensor Voltage Out of Range |
| P0E311C | Boosting Converter Voltage Sensor "A" Voltage Out of Range | ||
| P1C2D62 | Hybrid/EV Battery "A" Voltage Sensor/Boosting Converter Voltage Sensor "A" Signal Compare Failure | ||
| Motor generator control system | P0D2D16 | Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Below Threshold | |
| P0D2D17 | Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Above Threshold | ||
| P0D2D1F | Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Intermittent | ||
| P0E3116 | DC/DC Converter Voltage Sensor "A" (VL) Circuit Voltage Below Threshold | ||
| P0E3117 | DC/DC Converter Voltage Sensor "A" (VL) Circuit Voltage Above Threshold | ||
| P0E311F | DC/DC Converter Voltage Sensor "A"(VL) Circuit Intermittent | ||
| P0E5717 | DC/DC Converter Voltage Sensor "A"(VL) Circuit Voltage Above Threshold | ||
P31B300 may be output as a result of the malfunction indicated by the DTCs above.
The chart above is listed in inspection order of priority.
Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)
Turn the power switch off.
A
B
C
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / HV battery / Data List / Hybrid/EV Battery Voltage
Read the Data List.
| Tester Display |
|---|
| Hybrid/EV Battery Voltage |
Be sure not to measure when the power switch is on (READY).
Make a note of the data list item "Hybrid/EV Battery Voltage".
Turn the power switch off.
| Proceed to |
|---|
| NEXT |
NEXT
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the electric vehicle battery plug assembly.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>BATTERY PLUG (for LITHIUM-ION BATTERY)>REMOVAL
Disconnect the z23 and z27 HV battery high voltage connectors.
Insulate each disconnected high-voltage connector with insulating tape. Wrap the connector from the wire harness side to the end of the connector.
| *a | No. 2 HV Supply Stack Sub-assembly Connector
(Hybrid Battery Terminal Block Side) |
| *b | No. 1 HV Supply Stack Sub-assembly Connector
(HV Battery Junction Block Assembly Side) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition |
|---|---|
| z23-1 - z27-1 | Power switch off |
Do not allow the probes of the electrical tester to contact each other during this inspection.
Check the value in the data list "Hybrid/EV Battery Voltage" and the hybrid/EV battery voltage value that was actually measured.
| Result | Proceed to |
|---|---|
| When the difference between "Hybrid/EV Battery Voltage" in the Data List and the measurement value of the HV battery voltage is 5 V or more. | A |
| Other than above | B |
Reconnect the z23 and z27 HV battery high voltage connectors.
Install the electric vehicle battery plug assembly.
A
B
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>BATTERY ECU (for LITHIUM-ION BATTERY)>REMOVAL
| Proceed to |
|---|
| NEXT |
NEXT
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY STACK (for LITHIUM-ION BATTERY)>REMOVAL
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Read the freeze frame data of DTC P31B300.
| Result | Proceed to |
|---|---|
| "Hybrid/EV Battery Voltage" is less than 292 V. | A |
| Other than above | B |
Turn the power switch off.
A
B
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>BATTERY ECU (for LITHIUM-ION BATTERY)>REMOVAL
| Proceed to |
|---|
| NEXT |
NEXT
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY STACK (for LITHIUM-ION BATTERY)>REMOVAL