Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM (for LITHIUM-ION BATTERY) › from 2020.08
RM33C0E _51 Engine / Hybrid System _065433 HYBRID / BATTERY CONTROL _0442440 HYBRID CONTROL SYSTEM(for LITHIUM-ION BATTERY) C

HYBRID / BATTERY CONTROL  HYBRID CONTROL SYSTEM(for LITHIUM-ION BATTERY)  P1AC413  Hybrid/EV Battery Stack 1 Current Interrupt Device Circuit Open  


DTC SUMMARY

MALFUNCTION DESCRIPTION


Current interrupt devices (CIDs), which mechanically shut off the high-voltage circuit, are installed in each HV battery cell to protect the HV battery from overcharge (overvoltage).

The cause of this malfunction may be one of the following:

Battery ECU assembly internal malfunction
·

Battery ECU assembly malfunction



DESCRIPTION

The hybrid vehicle control ECU assembly detects a shut-off by a CID in a HV battery cell.

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate
P1AC413 Hybrid/EV Battery Stack 1 Current Interrupt Device Circuit Open The hybrid vehicle control ECU assembly detects that a CID has operated in the HV battery.
When the power switch is on (READY), the hybrid vehicle control ECU assembly receives a signal indicating a drop in cell voltage from the battery ECU assembly due to the voltage before boosting being out of the normal range or the cumulative change in voltage before boosting is large for a certain amount of time.
(1 trip detection logic)
Battery ECU assembly Comes on Master Warning Light:
Comes on

Related Data List
DTC No. Data List
P1AC413
·

Hybrid/EV Battery Voltage

·

VL-Voltage before Boosting

·

VH-Voltage after Boosting



CONFIRMATION DRIVING PATTERN

HINT:

After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM (for LITHIUM-ION BATTERY)>UTILITY


1.

Connect the GTS to the DLC3.

2.

Turn the power switch on (IG) and turn the GTS on.

3.

Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).

4.

Turn the power switch off and wait for 2 minutes or more.

5.

Turn the power switch on (IG) and turn the GTS on.

6.

Turn the power switch on (READY) and wait for 3 minutes or more.

HINT:

According to the display on the GTS, read the Data List and monitor the values of "Hybrid/EV Battery Voltage" and "VL-Voltage before Boosting" for 3 minutes. If the difference between "Hybrid/EV Battery Voltage" and "VL-Voltage before Boosting" is always less than 50 V, the vehicle has returned to normal.


7.

Enter the following menus: Powertrain / Hybrid Control / Utility / All Readiness.

8.

Check the DTC judgment result.

HINT:
·

If the judgment result shows NORMAL, the system is normal.

·

If the judgment result shows ABNORMAL, the system has a malfunction.

·

If the judgment result shows INCOMPLETE or N/A, perform driving pattern again.




CAUTION / NOTICE / HINT

NOTICE:

Do not turn the power switch on (READY) before completing repairs as this may cause a malfunction.


PROCEDURE

1.CHECK DTC OUTPUT (HYBRID CONTROL, HV BATTERY)
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).

NOTICE:

If the DTCs are cleared or the cable is disconnected and reconnected to the negative (-) auxiliary battery terminal before performing repairs, turning the power switch on (READY) may cause a malfunction. Do not turn the power switch on (READY).



c.

Enter the following menus: Powertrain / Hybrid Control, HV Battery / Trouble Codes.


d.

Check for DTCs.

Powertrain > Hybrid Control > Trouble Codes
50001 397
Powertrain > HV Battery > Trouble Codes
50001 398
Result:
Result Proceed to
P1AC413 only is output, or DTCs except the ones in the table below are also output. A
DTCs of hybrid battery system in the tables below are output. B


Malfunction Content System Relevant DTC
System malfunction Hybrid battery system P1AC413 Hybrid/EV Battery Stack 1 Current Interrupt Device Circuit Open
P1AC49E Hybrid/EV Battery Stack 1 Current Interrupt Device Stuck On
P1AC513 Hybrid/EV Battery Stack 2 Current Interrupt Device Circuit Open
P1AC59E Hybrid/EV Battery Stack 2 Current Interrupt Device Stuck On


HINT:
·

P1AC413 may be output as a result of the malfunction indicated by the DTCs above.

(a)

The chart above is listed in inspection order of priority.

(b)

Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)




e.

Turn the power switch off.



A

2.CHECK DTC OUTPUT (HYBRID CONTROL, MOTOR GENERATOR AND HV BATTERY)

B

2.CHECK DTC OUTPUT (HYBRID CONTROL, MOTOR GENERATOR AND HV BATTERY)
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control, Motor Generator and HV Battery / Trouble Codes.


d.

Check for DTCs.

Powertrain > Hybrid Control > Trouble Codes
50001 397
Powertrain > Motor Generator > Trouble Codes
50001 395
Powertrain > HV Battery > Trouble Codes
50001 398
Result:
Result Proceed to
P1AC413 only is output, or DTCs except the ones in the table below are also output. A
DTCs of hybrid control system in the tables below are output. B
DTCs of motor generator control system in the tables below are output. C
DTCs of hybrid battery system in the tables below are output. D


Malfunction Content System Relevant DTC
Microcomputer malfunction Hybrid control system P060647 Hybrid/EV Powertrain Control Module Processor Watchdog / Safety MCU Failure
P0A1B49 Drive Motor "A" Control Module Internal Electronic Failure
Motor generator control system P0A1A47 Generator Control Module Watchdog / Safety MC Failure
P0A1A49 Generator Control Module Internal Electronic Failure
P0A1B1F Generator Control Module Circuit Intermittent
P1C2A1C Generator A/D Converter Circuit Circuit Voltage Out of Range
P1C2A49 Generator A/D Converter Circuit Internal Electronic Failure
P313383 Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect
P313386 Communication Error from Generator to Drive Motor "A" Signal Invalid
Hybrid battery system P060A47 Hybrid/EV Battery Energy Control Module Monitoring Processor Watchdog / Safety MCU Failure
P060B16 Hybrid/EV Battery Energy Control Module A/D Processing Circuit Voltage Below Threshold
P060B49 Hybrid/EV Battery Energy Control Module A/D Processing Internal Electronic Failure
Power source circuit malfunction Motor generator control system P06D61C Generator Control Module Offset Power Circuit Voltage Out of Range
Hybrid battery system P1CBB12 Hybrid/EV Battery Current Sensor Power Supply Circuit Short to Auxiliary Battery
P1CBB14 Hybrid/EV Battery Current Sensor Power Supply Circuit Short to Ground or Open
Communication system malfunction Hybrid control system P312387 Lost Communication with Drive Motor Control Module "A" from Hybrid/EV Control Module Missing Message
U011187 Lost Communication with Hybrid/EV Battery Energy Control Module "A" Missing Message
Motor generator control system P313387 Communication Error from Generator to Drive Motor "A" Missing Message
Hybrid battery system P060687 Hybrid/EV Battery Energy Control Module Processor to Monitoring Processor Missing Message
P060A87 Hybrid/EV Battery Energy Control Module Processor from Monitoring Processor Missing Message
Sensor and actuator circuit malfunction Motor generator control system P0D2D16 Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Voltage Below Threshold
P0D2D17 Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Voltage Above Threshold
Hybrid battery system P0ABF11 Hybrid/EV Battery Current Sensor "A" Circuit Short to Ground
P0ABF15 Hybrid/EV Battery Current Sensor "A" Circuit Short to Auxiliary Battery or Open
P0ABF28 Hybrid/EV Battery Current Sensor "A" Signal Bias Level Out of Range / Zero Adjustment Failure
P0ABF2A Hybrid/EV Battery Current Sensor "A" Signal Stuck In Range
P0B0E11 Hybrid/EV Battery Current Sensor "B" Circuit Short to Ground
P0B0E15 Hybrid/EV Battery Current Sensor "B" Circuit Short to Auxiliary Battery or Open
P0B1362 Hybrid/EV Battery Current Sensor "A"/"B" Signal Compare Failure
System malfunction Hybrid control system P0A1F94 Hybrid/EV Battery Energy Control Module Unexpected Operation
P0ABF00 Hybrid/EV Battery Current Sensor "A" Circuit Range/Performance
P0D2D1C Drive Motor "A" Inverter Voltage Sensor Voltage Out of Range
P0D4C1C Hybrid/EV Battery Charger Hybrid/EV Battery Input Voltage Sensor Voltage Out of Range
P0E311C Boosting Converter Voltage Sensor "A" Voltage Out of Range
P1C2D62 Hybrid/EV Battery "A" Voltage Sensor/Boosting Converter Voltage Sensor "A" Signal Compare Failure
P1C8349 High Voltage Power Resource Circuit Voltage Sensor after Boosting Malfunction
Motor generator control system P0CA300 DC/DC Converter Step Up Voltage Performance
P1CB69E Drive Motor "A" Inverter Voltage Sensor(VH) Stuck On

HINT:
·

P1AC413 may be output as a result of the malfunction indicated by the DTCs above.

(a)

The chart above is listed in inspection order of priority.

(b)

Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)





e.

Turn the power switch off.



A

3.REPLACE BATTERY ECU ASSEMBLY

B

C

D

3.REPLACE BATTERY ECU ASSEMBLY

NEXT

4.SIMULATION TEST
4.SIMULATION TEST
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG) and turn the GTS on.

NOTICE:

Do not turn the power switch on (READY) before completing repairs as this may cause a malfunction.



c.

Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.


d.

Clear the DTCs and freeze frame data.

Powertrain > Hybrid Control > Clear DTCs
50002 397

e.

Turn the power switch off and wait for 2 minutes or more.


f.

Turn the power switch on (IG) and wait for 30 seconds or more.


g.

Enter the following menus: Powertrain / Hybrid Battery / Trouble Codes.


h.

Check if DTCs are output.

Powertrain > HV Battery > Trouble Codes
50001 398

Result:
Result Proceed to
No DTCs are output. A
DTCs of hybrid battery system are output. B


i.

Turn the power switch off.



A

END

B