Refer to the description for DTC P0ABF11.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
| P0B1362 | Hybrid/EV Battery Current Sensor "A"/"B" Signal Compare Failure | A battery current sensor is malfunctioning.*
(1 trip detection logic) |
·
HV battery junction block assembly ·
Battery ECU assembly ·
No. 1 HV supply stack sub-assembly ·
No. 2 HV supply stack sub-assembly |
Comes on | Master Warning Light:
Comes on |
*: The difference in output of the main and sub battery current sensors is large.
| DTC No. | Data List |
|---|---|
| P0B1362 | Hybrid/EV Battery Current |
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Connect the GTS to the DLC3.
Turn the power switch on (IG) and turn the GTS on.
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the power switch off and wait for 2 minutes or more.
Turn the power switch on (IG) and turn the GTS on.
Drive the vehicle on urban roads for approximately 10 minutes.
Enter the following menus: Powertrain / HV Battery / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE or N/A, perform driving pattern again.
Refer to the wiring diagram for DTC P0A9B11.
Before the following operations are conducted, take precautions to prevent electric shock by turning the power switch off, wearing insulated gloves, and removing the service plug grip from HV battery.
Inspecting the high-voltage system
Disconnecting the low voltage connector of the inverter with converter assembly
Disconnecting the low voltage connector of the HV battery
To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.
After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
| *a | Without waiting for 10 minutes |
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
Make sure to insulate the high-voltage connectors and terminals of the HV battery with insulating tape after removing it.
If the HV battery stored without insulating the connectors and terminals, electric shock or fire may result.
| *a | Dealer |
| *b | Battery Collection Agent |
When disposing of an HV battery, make sure to return it through an authorized collection agent who is capable of handling it safely. If the HV battery is returned via the manufacturer specified route, it will be returned properly and in a safe manner by an authorized collection agent.
Accidents such as electric shock may result if the HV battery is disposed of improperly or abandoned. Therefore, make sure to return all HV batteries through an authorized collection agent.
Before returning the HV battery, make sure to perform a recovery inspection.
Before returning the HV supply stack sub-assembly, make sure to perform a recovery inspection.
Make a note of the output DTCs as some of them may be necessary for recovery inspection of the HV battery and HV supply stack sub-assemblies.
After removing the HV battery, keep it away from water. Exposure to water may cause the HV battery to produce heat, resulting in a fire.
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / HV Battery and Hybrid Control / Trouble Codes.
Check for DTCs.
| Result | Proceed to |
|---|---|
| "P0B1362" only is output, or DTCs except the ones in the table below are also output. | A |
| DTCs of hybrid battery system in the table below are output. | B |
| DTCs of hybrid control system in the table below are output. | C |
| System | Relevant DTC | |
|---|---|---|
| Hybrid battery system | P060A47 | Hybrid/EV Battery Energy Control Module Monitoring Processor Watchdog / Safety MCU Failure |
| P060B49 | Hybrid/EV Battery Energy Control Module A/D Processing Internal Electronic Failure | |
| P060687 | Hybrid/EV Battery Energy Control Module Processor to Monitoring Processor Missing Message | |
| Hybrid control system | P0A1F94 | Hybrid/EV Battery Energy Control Module Unexpected Operation |
Turn the power switch off.
A
B
C
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY STACK (for LITHIUM-ION BATTERY)>REMOVAL
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV RELAY ASSEMBLY (for LITHIUM-ION BATTERY)>REMOVAL
| Proceed to |
|---|
| NEXT |
NEXT
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / HV Battery / Clear DTCs.
Clear the DTCs and freeze frame data.
Drive the vehicle on urban roads for approximately 10 minutes.
| Proceed to |
|---|
| NEXT |
NEXT
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / HV Battery / Trouble Codes.
Check for DTCs.
| Result | Proceed to |
|---|---|
| DTCs are not output. | A |
| P0B1362 is also output. | B |
Turn the power switch off.
A
B
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>BATTERY ECU (for LITHIUM-ION BATTERY)>REMOVAL
| Proceed to |
|---|
| OK |
| NG |
OK
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY STACK (for LITHIUM-ION BATTERY)>REMOVAL
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY STACK (for LITHIUM-ION BATTERY)>REMOVAL
| Proceed to |
|---|
| OK |
| NG |
OK
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY STACK (for LITHIUM-ION BATTERY)>REMOVAL
NG