The necessary procedures (adjustment, calibration, initialization or registration) that must be performed after parts are removed and installed, or replaced during combination meter assembly removal/installation are shown below.
1. PRECAUTION
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION
64718C
2.REMOVE LUGGAGE TRIM SERVICE HOLE COVER
3. CHANGE POWER TILT AND POWER TELESCOPIC STEERING COLUMN SYSTEM SETTINGS (for Power Tilt and Power Telescopic Steering Column)
4.DISCONNECT CABLE FROM NEGATIVE AUXILIARY BATTERY TERMINAL
Click hereGeneral>MAINTENANCE>AUXILIARY BATTERY>REMOVAL
When disconnecting the cable, some systems need to be initialized after the cable is reconnected.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION
55435B
5.REMOVE NO. 1 METER HOOD CLUSTER
55436B
6.REMOVE NO. 2 METER HOOD CLUSTER
55410C
7.REMOVE INSTRUMENT CLUSTER FINISH PANEL ASSEMBLY
for Manual Tilt and Manual Telescopic Steering Column:
Release the tilt and telescopic lever and fully extend and lower the steering column assembly.
Lock the tilt and telescopic lever.
|
Protective Tape |
Apply protective tape to the area shown in the illustration.
|
Protective Tape |
Apply protective tape to the area shown in the illustration.
|
Remove in this Direction |
Disengage the 2 claws and 4 clips to separate the instrument cluster finish panel assembly.
Remove the 2 clips.
|
Place Hand Here |
|
Remove in this Direction |
Disengage the 2 clips as shown in the illustration.
|
Place Hand Here |
|
Remove in this Direction |
Disengage the 2 clips as shown in the illustration.
|
Remove in this Direction |
Disengage the 2 guides as shown in the illustration.
Disconnect the connector to remove the instrument cluster finish panel assembly.
83100
8.REMOVE COMBINATION METER ASSEMBLY
Remove the 3 screws.
|
Remove in this Direction |
Disengage the 2 clips as shown in the illustration.
Disengage the clamp.
Disconnect each connector to remove the combination meter assembly.