In order to obtain a high purification rate of the carbon monoxide (CO), hydrocarbon (HC) and nitrogen oxide (NOx) components in the exhaust gas, a TWC is used. For the most efficient use of the TWC, the air-fuel ratio must be precisely controlled so that it is always close to the stoichiometric air-fuel level. To help the ECM to deliver accurate air-fuel ratio control, a heated oxygen sensor is used.
The heated oxygen sensor is located behind the TWC, and detects the oxygen concentration in the exhaust gas. Since the sensor is integrated with the heater that heats the sensing portion, it is possible to detect the oxygen concentration even when the intake air volume is low (the exhaust gas temperature is low).
When the air-fuel ratio becomes lean, the oxygen concentration in the exhaust gas is rich. The heated oxygen sensor informs the ECM that the post-TWC air-fuel ratio is lean (low voltage, i.e. less than 0.45 V).
Conversely, when the air-fuel ratio is richer than the stoichiometric air-fuel level, the oxygen concentration in the exhaust gas becomes lean. The heated oxygen sensor informs the ECM that the post-TWC air-fuel ratio is rich (high voltage, i.e. more than 0.45 V). The heated oxygen sensor has the property of changing its output voltage drastically when the air-fuel ratio is close to the stoichiometric level.
The ECM uses the supplementary information from the heated oxygen sensor to determine whether the air-fuel ratio after the TWC is rich or lean, and adjusts the fuel injection time accordingly. Thus, if the heated oxygen sensor is working improperly due to internal malfunctions, the ECM is unable to compensate for deviations in the primary air-fuel ratio control.
| DTC No. | DTC Detecting Condition | Trouble Area |
|---|---|---|
| P0136/27 | While vehicle driving with warmed engine, heated oxygen sensor (bank 1 sensor 2) output does not switch from RICH to LEAN or from LEAN to RICH.
(2 trip detection logic) |
·
Open or short in heated oxygen sensor (sensor 2) circuit ·
Heated oxygen sensor (sensor 2) ·
ECM |
This confirmation driving pattern is used in the "PERFORM CONFIRMATION DRIVING PATTERN" procedure of the following diagnostic troubleshooting procedure.
(a) Connect an intelligent tester to the DLC3.
(b) Turn the ignition switch on (IG) and turn the tester on.
(c) Clear DTCs.
(d) Switch the ECM from normal mode to check mode.
(e) Start the engine.
(f) Allow the engine to idle for 60 seconds.
(g) Drive the vehicle at a vehicle speed of more than 40 km/h (29 mph) for 40 seconds or more.
(h) Allow the engine to idle for 10 seconds or more.
(i) Repeat steps (g) and (h) described above at least 10 times.
If the conditions in this test are not strictly followed, malfunctions may not be detected.
Sensor 2 refers to the sensor mounted behind the Three-Way Catalytic Converter (TWC) and located far from the engine assembly.
Intelligent tester only:
Malfunctioning areas can be identified by performing the A/F Control function provided in the Active Test. The A/F Control function can help to determine whether the heated oxygen (HO2) sensor and other potential trouble areas are malfunctioning.
The following instructions describe how to conduct the A/F control operation using an intelligent tester.
Connect the intelligent tester to the DLC3.
Start the engine and turn the intelligent tester ON.
Warm up the engine at an engine speed of 2500 rpm for approximately 90 seconds.
On the tester, select the following menu items: Powertrain / Engine and ECT / Active Test / A/F Control.
Perform the A/F Control operation with the engine in an idling condition (press the right or left button to change the fuel injection volume).
Monitor the output voltage of the heated oxygen sensor displayed on the tester.
The A/F Control operation lowers the fuel injection volume by 12.5% or increases the injection volume by 25%.
Each sensor reacts in accordance with increases and decreases in the fuel injection volume.
| Tester Display
(Sensor) |
Injection Volume | Status | Voltage |
|---|---|---|---|
| O2S B1 S2
(HO2) |
+ 25% | Rich | More than 0.2 V |
| O2S B1 S2
(HO2) |
- 12.5% | Lean | Less than 0.1 V |
Read freeze frame data using the intelligent tester. Freeze frame data records the engine conditions when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air-fuel ratio was lean or rich, and other data from the time the malfunction occurred.
Connect an intelligent tester to the DLC3.
Turn the ignition switch to ON and turn the intelligent tester ON.
Select the following menu items: Powertrain / Engine and ECT / DTC.
Read DTCs.
| Display (DTC Output) | Proceed To |
|---|---|
| P0136 | A |
| P0136 and other DTCs | B |
If any DTCs other than P0136 are output, troubleshoot those DTCs first.
A
B
Connect an intelligent tester to the DLC3.
Turn the ignition switch to ON and turn the intelligent tester ON.
Select the following menu items: Powertrain / Engine and ECT / Data List / O2S B1 S2.
Allow the engine to run at 2500 rpm for 3 minutes.
Depress the accelerator pedal quickly until the engine rpm reaches 4000 rpm 3 times.
The heated oxygen sensor voltage alternates between below 0.45 V and 0.6 V or more.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Clear all DTCs before performing the confirmation driving pattern.
| Proceed to |
|---|
| NEXT |
NEXT
Connect an intelligent tester to the DLC3.
Turn the ignition switch to ON and turn the intelligent tester ON.
Select the following menu items: Powertrain / Engine and ECT / DTC.
Read DTCs.
| Display (DTC Output) | Proceed To |
|---|---|
| No output | A |
| P0136 | B |
A
B
Disconnect the heated oxygen sensor connector.
Measure the resistance of the sensor.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 (HT1B) - 2 (+B) | 20°C (68°F) | 11 to 16 Ω |
| 1 (HT1B) - 4 (E2) | Always | 10 kΩ or higher |
Reconnect the heated oxygen sensor connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the heated oxygen sensor connector.
Remove the NO. 2 integration relay from the relay block No.2.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A62-2 (+B) - 2D-4 | Always | Below 1Ω |
| A62-2 (+B) or 2D-4 - Body ground | Always | 10 kΩ or higher |
Reconnect the heated oxygen sensor connector.
Reinstall the NO. 2 integration relay.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the heated oxygen sensor connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| B77-13 (OX1B) - A62-3 (OX1B) | Always | Below 1Ω |
| B77-9 (E2) - A62-4 (E2) | Always | Below 1Ω |
| B77-13 (OX1B) or A62-3 (OX1B) - Body ground | Always | 10 kΩ or higher |
Reconnect the ECM connector.
Reconnect the heated oxygen sensor connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG