22204
1.INSTALL MASS AIR FLOW METER
Install the mass air flow meter with the 2 screws onto the air cleaner assembly.
1.0 N*m (9.8 kgf*cm, 8.5 in.*lbf)
17700
2.INSTALL AIR CLEANER ASSEMBLY
Install the air cleaner assembly with the 4 bolts.
18 N*m (184 kgf*cm, 13 ft.*lbf)
Connect the mass air flow meter connector and harness clamp.
Connect the intake hose and tighten the hose clamp.
Connect the cool air intake hose with the bolt and tighten the hose clamp.
19 N*m (194 kgf*cm, 14 ft.*lbf)