1.INSPECT LIGHTING TIME OF GLOW INDICATOR LIGHT
Turn the ignition switch ON, and measure the lighting time.
15 - 19.5 seconds
2.DISCONNECT PRE-HEATING TIMER CONNECTOR
LOCATION: See relay locations in Electrical Wiring Diagram.
3.INSPECT PRE-HEATING TIMER CIRCUIT
Check the connector on the wire harness side as shown in these chart:
| Check for | Tester connection | Condition | Specified value |
|---|---|---|---|
| Voltage | G-IND - Ground | Ignition switch OFF | No voltage |
| Ignition switch ON | Battery voltage | ||
| Voltage | IG - Ground | Ignition switch OFF | No voltage |
| Ignition switch ON | Battery voltage | ||
| Continuity | EG - Ground | - | Continuity |
4.RECONNECT PRE-HEATING TIMER CONNECTOR
28610
5.INSPECT GLOW PLUG RELAY
19850
6. GLOW PLUGS