Home › Engine / Hybrid System › 1HZ STARTING › PRE-HEATING SYSTEM(for Fixed Delay Type)
RM2850E _51 Engine / Hybrid System _073156 1HZ STARTING _0355979 PRE-HEATING SYSTEM(for Fixed Delay Type) G

1HZ STARTING  PRE-HEATING SYSTEM(for Fixed Delay Type)  ON-VEHICLE INSPECTION  


PROCEDURE

Hide 1.INSPECT LIGHTING TIME OF GLOW INDICATOR LIGHT

a.

Turn the ignition switch ON, and measure the lighting time.

Light lighting time:

15 - 19.5 seconds



Hide 2.DISCONNECT PRE-HEATING TIMER CONNECTOR

a.

LOCATION: See relay locations in Electrical Wiring Diagram.


Hide 3.INSPECT PRE-HEATING TIMER CIRCUIT

a.
A423128

Check the connector on the wire harness side as shown in these chart:

Check for Tester connection Condition Specified value
Voltage G-IND - Ground Ignition switch OFF No voltage
Ignition switch ON Battery voltage
Voltage IG - Ground Ignition switch OFF No voltage
Ignition switch ON Battery voltage
Continuity EG - Ground - Continuity


Hide 4.RECONNECT PRE-HEATING TIMER CONNECTOR