22204
1.INSTALL MASS AIR FLOW METER
Install the mass air flow meter with the 2 screws onto the air cleaner assembly.
17700
2.INSTALL AIR CLEANER ASSEMBLY
Install the air cleaner assembly with the 4 bolts.
18 N*m (184 kgf*cm, 13 ft.*lbf)
Connect the inlet hose and tighten the hose clamp.
Connect the mass air flow meter connector and harness clamp.
Connect the cool air intake hose with the 2 bolts and tighten the hose clamp.
19 N*m (194 kgf*cm, 14 ft.*lbf)