The skid control ECU (brake actuator assembly) is connected to the combination meter assembly via CAN communication.
If any of the following is detected, the brake warning light remains on:
The skid control ECU (brake actuator assembly) connector is disconnected from the skid control ECU (brake actuator assembly).
The brake fluid level is insufficient.
EBD operation is not possible.
The vacuum inside the brake booster decreases.
When replacing the skid control ECU (brake actuator assembly), perform zero point calibration and store system information (Click hereBrake>BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS>ANTI-LOCK BRAKE SYSTEM(w/ Brake pedal Load Sensing Switch)>CALIBRATION).
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
| Result | Proceed to |
|---|---|
| DTC is not output | A |
| DTC is output | B |
A
B
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Turn the ignition switch off.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A71-25 (GND1) - Body ground | Always | Below 1 Ω |
| *a | Front view of wire harness connector
(to Skid Control ECU (Brake Actuator Assembly)) |
| Result | Proceed to |
|---|---|
| OK (N04C-UH, N04C-VQ, N04C-VL) | A |
| OK (2TR-FE) | B |
| NG | C |
A
B
C
Start the engine.
Idle the engine.
Disconnect the A6 vacuum warning switch assembly connector and check the brake warning light.
| Result | Proceed to |
|---|---|
| Brake warning light does not turn off | A |
| Brake warning light turns off | B |
If the brake warning light turns off, the vacuum warning switch has an internal short circuit.
A
B
Turn the ignition switch off.
Disconnect the A7 vacuum warning switch assembly connector.
Disconnect the J1 combination meter assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| J1-32 (BRL) - A6-1 | Always | Below 1 Ω |
| J1-32 (BRL) or A6-1 - Body ground | Always | 10 kΩ or higher |
| A7-1 - Body ground | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Turn the ignition switch off.
With the brake fluid at the specified level, disconnect the F2 brake fluid level warning switch (brake master cylinder reservoir assembly) connector and check the brake warning light.
| Result | Proceed to |
|---|---|
| Brake warning light does not turn off | A |
| Brake warning light turns off | B |
If the brake warning light turns off, the brake fluid level warning switch (brake master cylinder reservoir assembly) has an internal short circuit.
A
B
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| J1-31 (SW) - F2-1 (+) | Always | Below 1 Ω |
| J1-31 (SW) or F2-1 (+) - Body ground | Always | 10 kΩ or higher |
| F2-2 (E) - Body ground | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Reinstall the reservoir filler cap and strainer.
Reconnect the J1 combination meter assembly connector, A6 and A7 vacuum warning switch assembly connectors, F2 brake fluid level warning switch (brake master cylinder sub-assembly) connector and A71 skid control ECU (brake actuator assembly) connector.
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Chassis / ABS/VSC/TRC / Data List.
According to the display on the GTS, read the Data List.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Brake Warning Light | Brake warning light/ ON or OFF | ON: Warning light on
OFF: Warning light off |
- |
Check the GTS display condition of the brake warning light.
| Result | Proceed to |
|---|---|
| Display of the Data List remains OFF | A |
| Display of the Data List remains ON | B |
A
Click hereVehicle Interior>METER / GAUGE / DISPLAY>METER / GAUGE SYSTEM>HOW TO PROCEED WITH TROUBLESHOOTING
B