| DTC Code | DTC Detection Condition | Trouble Area |
|---|---|---|
| C1266/66 | When vehicle speed is 6 km/h (4 mph) or more, an open or short circuit in the EXO signal circuit continues for 0.3 seconds or more. | ·
ECU-B NO. 8 fuse*2 ·
EXO circuit ·
ECM*1 ·
Stop light control ECU*2 ·
Skid control ECU |
*1: for N04C-UH
*2: for 1HZ
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
Disconnect the ECM*1 or stop light control ECU*2 connector.
*1: for N04C-UH
*2: for 1HZ
Disconnect the skid control ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A50-18 (EXO) - A52-30 (ABS)*1
A50-18 (EXO) - A73-9 (ACC)*2 |
Always | Below 1 Ω |
| A50-18 (EXO) - Body ground | Always | 10 kΩ or higher |
*1: for N04C-UH
*2: for 1HZ
| Result | Proceed to |
|---|---|
| OK (for N04C-UH) | A |
| OK (for 1HZ) | B |
| NG | C |
A
B
C
Turn the ignition switch off.
Reconnect the ECM connector.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A52-30 (ABS) - Body ground | Ignition switch ON | 11 to 14 V |
| *a | Component with harness connected
(ECM) |
| Result | Proceed to |
|---|---|
| NG | A |
| OK | B |
A
B
Turn the ignition switch off.
Measure the voltage and resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A73-6 (+B) - Body ground | Ignition switch ON | 11 to 14 V |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A73-8 (GND) - Body ground | Always | Below 1 Ω |
| *a | Front view of wire harness connector
(to Stop Light Control ECU) |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Turn the ignition switch off.
Reconnect the stop light control ECU connector.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A73-9 (ACC) - A73-8 (GND) | Ignition switch ON | 11 to 14 V |
| *a | Component with harness connected
(Stop Light Control ECU) |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Turn the ignition switch off.
Reconnect the skid control ECU connector.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A50-18 (EXO) - Body ground | Ignition switch ON | 11 to 14 V |
| *a | Component with harness connected
(Skid Control ECU) |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Turn the ignition switch off.
Drive the vehicle at a speed of 6 km/h (4 mph) or more for 10 seconds or more.
Check if the same DTC is recorded (Click hereBrake>BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS>ANTI-LOCK BRAKE SYSTEM (w/o Brake pedal Load Sensing Switch)>DTC CHECK / CLEAR).
| Result | Proceed to |
|---|---|
| DTC (C1266/66) is not output | A |
| DTC (C1266/66) is output | B |
A
Click hereGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>HOW TO PROCEED WITH TROUBLESHOOTING
B