This resistor is used to change the air-fuel ratio of the air-fuel mixture.
The idle mixture is adjusted using this resistor.
Turning the idle mixture adjusting screw clockwise moves the contacts inside the resistor, raising the terminal VAF voltage. Conversely, turning the screw counterclockwise lowers the terminal VAF voltage.
When the terminal VAF voltage rises, the ECM increases the injection volume slightly, marking the air-fuel mixture a little richer.
Always use a CO meter when adjusting the idle mixture. If a CO meter is not available, DO NOT ATTEMPT TO ADJUST IDLE MIXTURE.
Warm up the engine to normal operating temperature.
Switch all accessories OFF.
Connect all vacuum lines properly.
Connect the tachometer.
Check ignition timing correctly.
Check idle speed correctly.
Check that the CO meter is properly calibrated.
Race the engine at 2,500 rpm about 2 minutes.
Insert a tester probe at least 40 cm (1.3 ft.) into the tailpipe.
Measure the concentration for 1 to 3 minutes after racing the engine to allow the concentration to stabilize.
1.0 to 2.0 %
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Put the vehicle in the same condition as step 1 of this chart.
Using SST, adjust the idle mixture by turning the idle mixture adjusting screw in the variable resistor.
| Result | Proceed to |
|---|---|
| Concentration: 1.0 to 2.0 % | B |
| Change in CO concentration | C |
| No change in CO concentration | A |
Always check idle speed after turning the idle mixture adjusting screw. If it is incorrect, readjust idle speed.
The idle mixture adjusting screw can be turned within 180 degrees. Do not turn this screw more than the specified.
A
B
C
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition |
|---|---|
| 1 - 2 | 3.5 to 6.5 Ω |
Measure the resistance according to the value(s) in the table below, when turning the idle mixture adjusting screw fully clockwise and counterclockwise using SST.
| Tester Connection | Specified Condition |
|---|---|
| 2 - 3 | Change from about 5 kΩ to 0 kΩ accordingly |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Turn the ignition switch to the ON position.
Measure the voltage according to the value(s) in the table below while slowly turning the idle mixture adjusting screw first fully counterclockwise and then fully clockwise, using SST.
| Tester Connection | Specified Condition |
|---|---|
| B73-25(VAF) - B73-28(E2) | Voltage changes smoothly from 0 V to about 5 V, i.e. does not suddenly jump up to 5 V down to 0 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the variable resistor connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| B90-2(VC) - B73-18(VC) | Always | Below 1 Ω |
| B90-3(VAF) - B73-25(VAF) | Always | Below 1 Ω |
| B90-1(E2) - B73-28(E2) | Always | Below 1 Ω |
| B90-2(VC) or B73-18(VC) - Body ground | Always | 10 kΩ or higher |
| B90-3(VAF) or B73-25(VAF) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG