SUPPLY PUMP INITIALIZATION PROCEDURE
After replacing the injection or supply pump assembly, suction control valve and/or the ECM:
If the engine is defective or stalls immediately after startup, the learned values of the ECM must be initialized. The engine can be initialized through the GTS or by short circuiting DLC3 terminals.
If the engine starts normally, initialization is not necessary. Perform steps procedure "A" and procedure "B" only.
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Do not start the engine.
Turn the GTS on.
Enter the following menus: Powertrain / Engine and ECT / Utility / Supply Pump Initialization.
Press "Next".
Press "Next".
Press "Exit".
Start the engine to check if the initialization is complete. If the engine cannot be started, repeat the initialization procedures from the beginning. (Procedure "A")
Idle the engine for at least 1 minute under the following conditions: (Procedure "B")
The engine coolant temperature is 60°C (140°F) or higher.
The fuel temperature is 20°C (68°F) or higher.
Do not race the engine immediately after starting the engine. After warming up the engine, racing the engine is acceptable.
The engine coolant temperature can be estimated by touching the outlet hose.
The fuel temperature can be estimated by using the ambient temperature as a substitute.
If the engine coolant temperature is difficult to estimate, use the GTS and enter the following menus: Powertrain / Engine and ECT / Data List / All Data / Coolant Temp.
Initialization is complete.
VENTURI ASSEMBLY INITIALIZATION PROCEDURE
Turn the ignition switch to ON (Procedure "A").
Do not start the engine.
Turn the ignition switch off and wait for 10 seconds (Procedure "B").
Repeat procedures "A" and "B" described above 2 times.