If the battery is weak or if the engine is difficult to start, recharge the battery and perform inspections again before returning the vehicle to the customer.
1.CHECK BATTERY CONDITION
Check the battery for damage and deformation. If severe damage, deformation or leak is found, replace the battery.
Check the volume of electrolyte quantity in each cell.
For batteries that are maintenance-free:
If the electrolyte volume is below the lower line, replace the battery.
If the electrolyte volume is above the lower line, check the battery voltage when cranking the engine.
If the voltage is less than 9.6 V, recharge or replace the battery.
Before checking the battery voltage, turn off all the electrical systems (headlights, blower motor, rear defogger, etc.).
For batteries that are not maintenance-free:
If the electrolyte volume is below the lower line, add distilled water to each cell. Then, recharge the battery and check the electrolyte specific gravity.
1.25 to 1.29 at 20°C (68°F)
If the electrolyte volume is above the lower line, check the battery voltage when cranking the engine. If the battery voltage is less than 9.6 V, recharge or replace the battery.
Before checking the battery voltage, turn off all the electrical systems (headlights, blower motor, rear defogger, etc.).
Check the voltage.
Turn the ignition switch off and turn on the headlights for 20 to 30 seconds. This will remove the surface charge from the battery.
Measure the battery voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Positive ( + ) terminal - Negative ( - ) terminal | 20°C ( 68 °F ) | 12.5 to 12.9 V |
If the voltage is not as specified, charge the battery.
2.INSPECT BATTERY TERMINAL AND FUSE
Check that the battery terminals are not loose or corroded.
If the terminals are corroded, clean the terminals.
Measure the resistance of the fuses.
Below 1 Ω
If the result is not as specified, replace the fuses.
3.INSPECT FAN AND GENERATOR V BELT
4.VISUALLY CHECK GENERATOR WIRING GENERATOR WIRING
Check that the wiring is in good condition.
5.CHECK FOR ABNORMAL NOISES
Check that the generator does not emit any abnormal noise while the engine is running.
6.INSPECT CHARGE WARNING LIGHT CIRCUIT
Turn the ignition switch to ON. Check that the charge warning light comes on.
Start the engine and check that the light turns off. If the light does not operate as specified, troubleshoot the charge warning light circuit.
7.INSPECT CHARGING CIRCUIT WITHOUT LOAD
Connect a voltmeter and an ammeter to the charging circuit as follows.
| *1 | Battery |
| *2 | Terminal B |
| *3 | Generator |
If a battery/generator tester is available, connect the tester to the charging circuit in accordance with the manufacturer's instructions.
Disconnect the wire from terminal B of the generator and connect it to the negative (-) lead of the ammeter.
Connect the ammeter positive (+) lead to terminal B of the generator.
Connect the voltmeter positive (+) lead to positive (+) terminal of the battery.
Ground the voltmeter negative (-) lead.
Check the charging circuit.
Keep the engine speed at 2000 rpm and check the reading on the ammeter and voltmeter.
10 A or less
13.2 to 14.8 V
If the voltmeter reading is higher than the standard voltage, replace the generator assembly.
If the battery is not fully charged, the ammeter reading will sometimes be higher than the standard current.
8.INSPECT CHARGING CIRCUIT WITH LOAD
With the engine running at 2000 rpm, turn the high beam headlights on and turn the heater blower switch to the HI position.
Check the reading on the ammeter.
30 A or higher
If the ammeter reading is below the standard current, repair the generator.
f the battery is fully charged, the ammeter reading will sometimes be less than the standard current. In this case, operate the wiper motor and the window defogger to increase the load and then check the charging circuit again.