Home › Engine / Hybrid System › N04C-WA (EMISSION CONTROL) › UREA TANK › from 2019.08
RM2850E _51 Engine / Hybrid System _082614 N04C-WA EMISSION CONTROL _0403729 UREA TANK A

N04C-WA EMISSION CONTROL  UREA TANK  REMOVAL  


PROCEDURE

Hide 77830A 1.REMOVE UREA TANK CAP ASSEMBLY

Hide 2.DRAIN UREA SOLUTION (AdBlue)

HINT:

If the urea solution (AdBlue) is full, this will contain the total amount (approximately 23 L), so prepare a container.


a.

Place the container below the urea tank assembly.


b.
A451089C02
1.969,0.917 2.229,0.24 2.229,0.24 2.458,0.24 true 0.74,1.365 0.74,1.156 false 0.688,1.396 0.896,1.594 0.208,0.198 10 false *1 2.49,0.146 2.729,0.365 0.24,0.219 10 false *2
*1 Tube Joint Clip
*2 Plug


Open out the tips of the tube joint clip and pull it out.


c.

Remove the plug and drain the urea solution (AdBlue).


d.

After draining the urea solution (AdBlue), attach the plug to the urea tank sub-assembly.


e.

Attach the tube joint clip.


Hide 77851A 3.REMOVE UREA TANK PROTECTOR

a.
A451090

Remove the 2 claws and clip, and then remove the urea tank protector.


Hide 4.DISCONNECT WIRE HARNESS

a.
A451091

Pull the tabs of the connector as shown in the illustration and disconnect the connector from the urea pump.


b.
A451092C01
0,0 0,0 false
V100135

Pull Out


Pull the connector lock and disconnect the connector from the combination gauge assembly.


c.
A451093

Disconnect the connector.


d.

Detach the 6 clamps and disconnect the wire harness.


Hide 77840A 5.DISCONNECT UREA TUBE WITH HEATER ASSEMBLY

a.
A451096

Detach the 3 clamps.


b.

Remove the urea tube with heater assembly from the urea pump.

NOTICE:

Check for dirt or mud on the urea pump and around the urea tube with heater connector before disconnection. Clean if necessary.


i.
A451094C01
0,0 0,0 false
V100135

Lift Up


Detach the lock claw by lifting up the cover.


ii.
A451095C01
0,0 0,0 false
V100135

Pinch
V100136

Pull


Pinch the retainer of the urea tube connector, and then pull the urea tube connector off of the urea tube with heater assembly.

NOTICE:
·

If there is any solidified urea solution (white solids) on the connection area, clean the solids off with a damp cloth, etc., before disconnecting the connector.

·

Be sure to disconnect the urea tube connector by hand.

·

Check for foreign matter in the urea pump and around the urea tube with heater connector. Clean if necessary. Foreign matter may damage the O-ring or cause leaks in the seal between the urea pump and urea tube with heater connector.

·

Put the urea pump and urea tube with heater connector ends in plastic bags to prevent damage and foreign matter contamination.





Hide 77801A 6.REMOVE UREA TANK SUB-ASSEMBLY

a.
A451097C02
2.552,0.896 2.552,0.74 2.552,0.74 2.76,0.74 false 0.844,0.563 0.844,0.406 0.844,0.406 0.719,0.406 false 0.521,0.313 0.708,0.51 0.188,0.198 10 false *a 2.802,0.646 2.99,0.833 0.188,0.188 10 true *a
*a Hook (Vehicle Side)


Remove the 5 bolts and 2 hooks, and then remove the urea tank sub-assembly from the body.


b.

Remove the bracket from the bolt.


Hide SG400 8.REMOVE UREA SENSOR ASSEMBLY