The DPF (Diesel Particulate Filter) system is controlled by the ECM to activate the forcible regeneration function automatically. However, depending on driving conditions, the forcible regeneration function may not be activated. In such a case, the indicator light on the combination meter and the DPF switch light blink to inform the driver. When the DPF switch is pressed, RGSW signals will be input into the ECM and the forcible regeneration function will activate.
If the vehicle continues to be driven without performing forcible regeneration while the indicator light is on, a buzzer intermittently sounds to inform the driver.
Inspect the fuses of this circuits related to this system before performing the following procedure.
After replacing the ECM, the new ECM needs registration (Click here Engine / Hybrid System>N04C-VJ (ENGINE CONTROL)>ECD SYSTEM>REGISTRATION) and initialization (Click here Engine / Hybrid System>N04C-VJ (ENGINE CONTROL)>ECD SYSTEM>INITIALIZATION).
| *a | Front view of wire harness connector
(to DPF Switch Assembly) |
Disconnect the DPF switch assembly connector.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| J30-4 (B) - Body ground | Ignition switch ON | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Inspect the DPF switch assembly.
Click hereEngine / Hybrid System>N04C-VJ (EMISSION CONTROL)>DPR SWITCH ASSEMBLY>INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Check the wire harness and connector.
Disconnect the DPF switch assembly connector.
Disconnect the ECM connectors.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| J30-1 (E) - A57-14 (RGSW) | Always | Below 1 Ω |
| J30-1 (E) or A57-14 (RGSW) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG