SYSTEM CONTROL
The air conditioner ECU has following controls.
| Control | Outline |
|---|---|
| Neural Network Control | This control is capable of effecting complex control by artificially simulating the information processing method of the nervous system of living organisms in order to establish a complex input or output relationship that is similar to a human brain. |
| Outlet Air Temperature Control | In compliance with the temperature set at the temperature control switch, the neural network control calculates the outlet temperature based on the input signals from various sensors. In addition, corrections in accordance with the signals from the evaporative temperature sensor and water temperature sensor are added to control the outlet air temperature. |
| Blower Control | Controls the blower motor in accordance with the airflow volume that has been calculated by the neural network control based on the input signals from various sensors. |
| Air Outlet Control | Automatically switches the outlets in accordance with the outlet mode ratio that has been calculated by the neural network control based on the input signals from various sensors. |
| Air Inlet Control | Automatically controls the air inlet control damper in accordance with the airflow volume that has been calculated by the neural network control. |
| Variable Capacity Compressor Control | Controls the compressor to turn ON or OFF and the discharge capacity based on the signals from various sensors. |
| Ambient Temperature Indication Control | Based on the signals from the ambient temperature sensor, this control calculates the ambient temperature, which is then corrected in the air conditioner ECU, and shown in the front air conditioner control panel. |
| Rear Window Defogger Control | ·
Switches the rear defogger ON for 15 minutes when the rear defogger switch is switched ON. ·
Switches it OFF if the switch is pressed while it is operating. |
| Pollen Removal Mode Control | Quickly removes pollen from the face areas of the driver and front passenger when the pollen removal mode switch is pressed. |
| Self-diagnosis | Checks the sensors in accordance with operation of front air conditioner switches, then clock displays a DTC (Diagnosis Trouble Code) to indicate if there is a malfunction or not (sensor check function). |
| Drives the actuators through a predetermined sequence in accordance with the operation of the front air conditioner switches (actuator check function). |
Neural Network Control
In the previous automatic air conditioner system, the ECU determined the required outlet air temperature and blower air volume in accordance with the calculation formula that has been obtained based on information received from the sensors. However, because the sensors of human beings are rather complex, a given temperature is sensed differently, depending on the environment in which the person is situated. For example, a given amount of solar radiation can feel comfortably warm in a cold climate, or extremely uncomfortable in a hot climate. Therefore, as a technique for effecting a higher level of control, a neural network is used in the automatic air conditioner system. With this technique, the data that has been collected under varying environmental conditions is stored in the ECU, which effects control to provide enhanced air conditioner comfort.
The neural network control consists of neurons in the input layer, intermediate layer, and output layer. The input layer neurons process the input data of the ambient temperature, the amount of sunlight, and the room temperature based on the outputs of the switches and sensors, and output them to the intermediate layer neurons. Based on this data, the intermediate layer neurons adjust the strength of the links among the neurons. The sum of these is then calculated by the output layer neurons in the form of the required outlet temperature, solar correction, target airflow volume, and outlet mode control volume. Accordingly, air conditioner ECU controls the servomotors and blower motor in accordance with the control volumes that have been calculated by the neural network control.
Pollen Removal Mode Control
When the pollen removal mode switch is pressed, the air conditioner ECU changes to the recirculation mode and face mode. This allows the air conditioner to direct clean air, which has passed through the clean air filter, to the face areas. Thus, the air conditioner removes pollen and captures it in the clean air filter.
From the pollen removal mode control, the air conditioner automatically resumes normal automatic mode control after 3 minutes at normal temperatures, or after 1 minute when the ambient temperature is low (5°C maximum).
PTC Heater Operating Conditions
The ON/OFF function of the PTC heater is controlled by the air conditioner ECU in accordance with the water temperature, engine speed, air mix setting, ambient temperature and electrical load (alternator power ratio). For example, the number of the operating PTC heaters varies with the water temperature as in the graph below.
CONSTRUCTION
Air Conditioner Control Panel
The front air conditioner control panel is push type for LHD models. The air conditioner is operated by using the push button.
The front air conditioner control panel is capacitive type for RHD models. The air conditioner is operated by using the capacitive type touch switches.
The front air conditioner control panel has been located in the center of the instrument panel and the rear air conditioner control panel has been located in the center of the roof to ensure excellent ease of use.
The front air conditioner control panel and rear air conditioner control panel (automatic type) use an LCD (Liquid Crystal Display) to display the set temperature, air outlet mode and blower speed to ensure excellent visibility.
Air Conditioner and Blower Units
Front Air Conditioner Unit
A semi-center location front air conditioner unit, in which the evaporator and heater core are placed in the vehicle's longitudinal direction, is used. As a result, the front air conditioner unit is made compact and lightweight.
| *1 | Evaporator | *2 | Heater Core |
| *a | Side View | *b | Top View |
| *c | Front | - | - |
Rear Air Conditioner Unit
The rear air conditioner unit is located inside the right quarter trim. The evaporator is laid out horizontally in this unit in order to direct the airflow smoothly upward. Full air mix type air mix doors are used for temperature adjustment, and a laminate slide type mode control door is used to make the rear air conditioner unit compact and lightweight.
| *1 | Mode Control Door (Laminate Slide Type) | *2 | Blower Unit |
| *3 | Heater Core | *4 | Evaporator |
| *5 | Air Mix Door | - | - |
| *a | Foot | *b | Face |
Partial Recirculation System
A partial recirculation system is provided on the China models and the RHD models for other destinations.
This system has an air inlet control door (sub) in the cabin side of the air inlet duct. Thus, it is able to cycle a small volume of recirculated air even in the FRESH mode, thus ensuring heating and air conditioning performance. When the blower switch is ON, the suction force of the blower fan opens this air inlet control door (sub).
| *1 | Air Inlet Control Door | *2 | Air Inlet Duct |
| *3 | Air Inlet Control Door (sub) | - | - |
| *a | Front | *b | FRESH |
| *c | RECIRC | *d | Blower Fan |
Evaporator
An RS (Revolutionary super-slim Structure) evaporator is used. Placing the tanks at the top and the bottom of the evaporator and adopting a micropore tube construction have realized the following effects:
The heat exchanging efficiency is improved.
The temperature distribution is made more uniform.
The evaporator is made thinner: 58 mm (2.3 in.)→ 38 mm (1.5 in.)
The evaporator body has been coated with a type of resin that contains an antibacterial agent in order to minimize the source of foul odor and the propagation of bacteria. The substrate below this coating consists of a chromate-free layer to help protect the environment.
| *a | Tank | *b | Cooling Fin |
| *c | Micropore Tube | *d | Antibacterial Agent |
| *e | Nylon Layer | *f | Chromate-free Layer |
| *g | Aluminum Matrix | - | - |
SFA-II Heater Core (SFA-II: Straight Flow Aluminum-II)
The SFA-II heater core has been made more compact and higher performance by making the core section finer and improving the shapes of the tank section and flow section. Also, the environment is considered. By using aluminum as the material, the amount of the environmental burden disposal (lead) is reduced.
| *a | OUT | *b | IN |
PTC (Positive Temperature Coefficient) Heater
On the China models, a PTC (Positive Temperature Coefficient) heater is used to improve the heating performance.
The PTC heater is located above the heater core in the front air conditioner unit.
The PTC heater consists of a PTC element, aluminum fin, and brass plate. When current is applied to the PTC element, it generates heat to warm the air that passes through the unit.
| *1 | PTC Heater | - | - |
| *a | Brass Plate | *b | PTC Element |
| *c | Aluminum Fin | - | - |
BUS Connector
A BUS connector is used in the wire harness connection that connects the servomotor with the air conditioner ECU.
| *a | BUS Connector | *b | Evaporator Temp. Sensor |
| *c | To Air Mix Servomotor (For Driver) | *d | To Air Inlet Servomotor |
| *e | To Air Conditioner ECU | *f | To Air Vent Servomotor |
| *g | To Air Mix Servomotor (For Front Passenger) | - | - |
| *a | BUS Connector | *b | Evaporator Temp. Sensor |
| *c | To Air Vent Servomotor | *d | To Air Mix Servomotor |
| *e | To Air Conditioner ECU | - | - |
The BUS connector has a built-in communication / drive IC, which communicates with each servomotor and sir conditioner ECU, actuates the servomotor, and has a position detection function. This realizes a more lightweight construction and reduce the number of wires.
| *a | Air Conditioner ECU | *b | Communication IC |
| *c | CPU | *d | BUS Connector |
| *e | Communication / Drive IC | *f | Servomotor |
| *a | Air Conditioner ECU | *b | CPU |
| *c | Drive IC | *d | Servomotor |
Servomotor
The pulse pattern type servomotor consists of a printed-circuit board and servomotor. The printed-circuit board has three contact points, and transmits the two ON/OFF signals with different pulse phases to the bus connector. The bus connector detects the damper position and movement direction with these signals, and transmits the results to the air conditioner ECU.
Clean Air Filter
A clean air filter (high efficiency type) is used to remove dust, pollen, and other micron particles from air entering from outside the vehicle to provide a comfortable cabin of clean air. The clean air filter is installed in the upper section of the blower fan for easy replacement without the need for tools by removing the one-touch clip in the glove box, making this easy to service.
| *1 | Clean Air Filter | - | - |
The replacement intervals are shown in the table on the right.
| Destination | Replacement Interval | |
|---|---|---|
| Normal Condition | Dusty Condition | |
| Australia | 30000 km or 18500 miles | 15000 km or 9000 miles |
| G.C.C. Countries
General Countries China |
20000 km or 12500 miles | |
Replace the clean air filter after the power source mode is selected to OFF.
Condenser
The new models use a sub-cool condenser. This is a multi-flow condenser consisting of three portions: a condensing portion, a super-cooling portion and a gas-liquid separator (modulator) all integrated together. This condenser uses a sub-cool cycle for its cooling cycle system to improve heat-exchanging efficiency.
In the sub-cool cycle, after the refrigerant passes through the condensing portion of the condenser, both the liquid refrigerant and the gaseous refrigerant that could not be liquefied are cooled again in the super-cooling portion. Thus, the refrigerant is sent to the evaporator in an almost completely liquefied state.
| *a | Multi-flow Condenser | *b | Condensing Portion |
| *c | Modulator | *d | Desiccant |
| *e | Filter | *f | Super-cooling Portion |
| *g | Gaseous Refrigerant | *h | Liquid Refrigerant |
The point at which the air bubbles disappear in the refrigerant of the sub-cool cycle is lower than the proper amount of refrigerant with which the system must be filled. Therefore, if the system is recharged with refrigerant based on the point at which the air bubbles disappear, the amount of refrigerant would be insufficient. As a result, the cooling performance of the system will be affected. If the system is overcharged with refrigerant, this will also lead to a reduced performance. For the proper method of verifying the amount of the refrigerant and to recharge the system with refrigerant, see Repair Manual.
A/C Compressor
An A/C compressor is a continuously variable capacity type in which its capacity varies in accordance with the cooling load of the air conditioner.
This compressor consists of the shaft, lug plate, piston, shoe, crank chamber, cylinder, and solenoid control valve.
The solenoid control valve that adjusts the suction pressure so that the suction pressure can be controlled as desired is provided.
The plastic DL (Damper Limiter) type A/C pulley is used.
On the models for the G.C.C. countries, the A/C compressor contains a flow control valve with a built-in internal Ps valve. It has the dual purpose of ensuring the proper cooling performance during high-load, high-speed operation and improving the control performance of the compressor. In addition, the suction resistance has been reduced by enlarging the suction passage, thus improving discharge capacity.
A rotary valve type is used to suction refrigerant gas into the cylinder.
| *a | A/C Pulley | *b | Shaft |
| *c | Crank Chamber | *d | Shoe |
| *e | Lug Plate | *f | Piston |
| *g | Cylinder | *h | Solenoid Control Valve |
Plastic DL Type A/C Pulley
This pulley contains dampers to absorb the torque fluctuations of the engine and a limiter mechanism to protect the drive belt in case the compressor locks. In the event that the compressor locks, the limiter mechanism causes the spoke portion of the pulley to break, thus separating the pulley from the compressor. To reduce weight, the pulley portion is made of plastic.
| *a | Limiter Mechanism | *b | Spoke Portion |
| *c | Damper | *d | Rotate Direction |
| *e | Pulley Portion (Plastic) | - | - |
OPERATION
MODE POSITION AND DAMPER OPERATION
Front Unit
This illustration is a model diagram showing the damper positions in each mode. The parts layout and the number of the dampers in the illustration are different from those of the actual system.
| Control Damper | Operation Position | Damper Position | Operation | |
|---|---|---|---|---|
| Air Inlet Control Damper | FRESH | A | Brings in fresh air. | |
| RECIRC | B | Recirculates internal air. | ||
| Air Mix Control Damper | MAX COLD - MAX HOT Temp. Setting (Auto A/C): 18 °C (64.4 °F) - 32 °C (89.6 °F) | C-E | Varies the mixture ratio of the fresh air and the recirculation air in order to regulate the temperature continuously from HOT to COLD. | |
| Mode Control Damper |
|
DEF | F, K, L, P, S, X | Defrosts the windshield through the front defroster and side register. |
|
FOOT/DEF | G, K, L, P, Q, Y | Defrosts the windshield through the front defroster and side register, while air is also blown out from the footwell register duct and rear footwell register duct. | |
|
FOOT | H, K, L, P, Q, Z | Air blows out of the footwell register duct, rear footwell register duct, and side register. In addition, air blows out slightly from the front defroster. | |
|
BI-LEVEL | I, K, N, P, R, Z | Air blows out of the center register, side register, footwell register duct and rear footwell register duct. | |
|
FACE | I, J, M, O, S, X | Air blows out of the center register and side register. | |
Rear Unit
| Control Damper | Control Position | Damper Position | Operation | |
|---|---|---|---|---|
| Mode Control Door |
|
FACE | A | Air blows out of the rear roof side register. |
|
BI-LEVEL | B | Air blows out of the rear roof side register and the rear footwell register. | |
|
FOOT | C | Air blows out of the rear footwell register. | |
| Air Mix Control Damper | MAX COLD - MAX HOT Temp. Setting (Auto A/C): 18 °C (64.4 °F) - 32 °C (89.6 °F) | D-E | Varies the mixture ratio of the fresh air and the recirculation air in order to regulate the temperature continuously from HOT to COLD. | |
A/C Compressor
The crank chamber is connected to the suction passage. A solenoid control valve is provided between the suction passage (low pressure) and the discharge passage (high pressure).
The solenoid control valve operates under duty cycle control in accordance with the signals from the air conditioner ECU.
| *a | Crank Chamber | *b | Piston |
| *c | Suction | *d | Discharge |
| *e | Air Conditioner ECU | *f | Suction Pressure |
| *g | Discharge Pressure | *h | Solenoid Control Valve |
When the solenoid control valve closes (solenoid coil is energized), a difference in pressure is created and the pressure in the crank chamber decreases. Then, the pressure that is applied to the right side of the piston becomes greater than the pressure that is applied to the left side of the piston. This compresses the spring and tilts the lug plate. As a result, the piston stroke increases and the discharge capacity increases.
| *a | Crank Chamber Pressure + Spring Force | *b | Piston Stroke: Large |
| *c | Suction | *d | Discharge |
| *e | Air Conditioner ECU | *f | Discharge Pressure |
| *g | Solenoid Control Valve | - | - |
When the solenoid control valve opens (solenoid coil is not energized), the difference in pressure disappears. Then, the pressure that is applied to the left side of the piston becomes the same as the pressure that is applied to the right side of the piston. Thus, the spring elongates and eliminates the tilt of the lag plate. As a result, there is no piston stroke and the discharge capacity decreases.
| *a | Crank Chamber Pressure + Spring Force | *b | Piston Stroke: Small |
| *c | Suction | *d | Discharge |
| *e | Air Conditioner ECU | *f | Suction Pressure |
| *g | Discharge Pressure | *h | Solenoid Control Valve |
Flow Control Valve with Built-in Internal Ps Valve
Ordinarily, the internal Ps valve does not operate because the solenoid control valve controls the air conditioner. The internal Ps valve operates to help reduce the discharge capacity in order to reduce the load on the compressor only if the compressor speed has increased suddenly or started at a high speed, or if the thermal load has changed suddenly.
| *a | Crank Chamber Pressure + Spring Force | *b | Suction |
| *c | Discharge | *d | Internal Ps Valve |
| *e | Air Conditioner ECU | *f | Suction Pressure |
| *g | Discharge Pressure | *h | Solenoid Control Valve |
No. 2 Ion Generator Sub-Assembly
The No. 2 ion generator sub-assembly operates according to the operation of the blower motor when the ion generator switch (air purifier switch assembly) is on.
The No. 2 ion generator sub-assembly emits "nanoe" ions that are electrically charged and encapsulated with water. The ions are discharged into the cabin through the driver side vent to provide skin-friendly clean air.*
*: According to temperature and humidity conditions, fan speed and air outlet mode selected, the No. 2 ion generator sub-assembly may not operate at full capacity.
Do not attempt to disassemble or repair the No. 2 ion generator sub-assembly because it contains high voltage parts.
Do not insert anything into the "nanoe" vent, attach anything to it, or use sprays around the "nanoe" vent on the driver side. These things may cause the ion generator sub-assembly not to work properly.
When the No. 2 ion generator sub-assembly operates, a small amount of ozone is emitted and may be faintly smelled in some situations. However, this is approximately the same as the amount that already exists in nature, such as in forests, and as such has no effect on the human body.
A slight noise may be heard during operation. This does not indicate a malfunction.
| *1 | No. 2 Ion Generator Sub-assembly | - | - |
| *a | Common Negative Ion "nanoe" Ions | *b | H2O |
| *c | Electron | - | - |
"nanoe" is a trademark of Panasonic Corporation.
DIAGNOSIS
The air conditioner ECU has a self-diagnosis function. It stores any operation failures in the air conditioner system memory in the form of DTC (Diagnostic Trouble Code). For details, see Repair Manual.