Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM › from 2016.05
NM24M0E _58 Vehicle Interior _061576 HEATING / AIR CONDITIONING _0300317 AIR CONDITIONING SYSTEM UN GENERAL/CONTROL/DETAILS F

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM  GENERAL/CONTROL/DETAILS  DETAILS  


SYSTEM CONTROL


a.

The air conditioner ECU has following controls.

Control Outline
Neural Network Control This control is capable of effecting complex control by artificially simulating the information processing method of the nervous system of living organisms in order to establish a complex input or output relationship that is similar to a human brain.
Outlet Air Temperature Control In compliance with the temperature set at the temperature control switch, the neural network control calculates the outlet temperature based on the input signals from various sensors. In addition, corrections in accordance with the signals from the evaporative temperature sensor and water temperature sensor are added to control the outlet air temperature.
Blower Control Controls the blower motor in accordance with the airflow volume that has been calculated by the neural network control based on the input signals from various sensors.
Air Outlet Control Automatically switches the outlets in accordance with the outlet mode ratio that has been calculated by the neural network control based on the input signals from various sensors.
Air Inlet Control Automatically controls the air inlet control damper in accordance with the airflow volume that has been calculated by the neural network control.
Variable Capacity Compressor Control Controls the compressor to turn ON or OFF and the discharge capacity based on the signals from various sensors.
Ambient Temperature Indication Control Based on the signals from the ambient temperature sensor, this control calculates the ambient temperature, which is then corrected in the air conditioner ECU, and shown in the front air conditioner control panel.
Rear Window Defogger Control
·

Switches the rear defogger ON for 15 minutes when the rear defogger switch is switched ON.

·

Switches it OFF if the switch is pressed while it is operating.


Pollen Removal Mode Control Quickly removes pollen from the face areas of the driver and front passenger when the pollen removal mode switch is pressed.
Self-diagnosis Checks the sensors in accordance with operation of front air conditioner switches, then clock displays a DTC (Diagnosis Trouble Code) to indicate if there is a malfunction or not (sensor check function).
Drives the actuators through a predetermined sequence in accordance with the operation of the front air conditioner switches (actuator check function).


b.

Neural Network Control

i.

In the previous automatic air conditioner system, the ECU determined the required outlet air temperature and blower air volume in accordance with the calculation formula that has been obtained based on information received from the sensors. However, because the sensors of human beings are rather complex, a given temperature is sensed differently, depending on the environment in which the person is situated. For example, a given amount of solar radiation can feel comfortably warm in a cold climate, or extremely uncomfortable in a hot climate. Therefore, as a technique for effecting a higher level of control, a neural network is used in the automatic air conditioner system. With this technique, the data that has been collected under varying environmental conditions is stored in the ECU, which effects control to provide enhanced air conditioner comfort.


ii.

The neural network control consists of neurons in the input layer, intermediate layer, and output layer. The input layer neurons process the input data of the ambient temperature, the amount of sunlight, and the room temperature based on the outputs of the switches and sensors, and output them to the intermediate layer neurons. Based on this data, the intermediate layer neurons adjust the strength of the links among the neurons. The sum of these is then calculated by the output layer neurons in the form of the required outlet temperature, solar correction, target airflow volume, and outlet mode control volume. Accordingly, air conditioner ECU controls the servomotors and blower motor in accordance with the control volumes that have been calculated by the neural network control.

Y209941E01
7,3.219 7,1.99 7,1.99 6.865,1.865 false 0.365,1.125 1.063,1.427 0.698,0.302 8 false Input Processing 2.313,0.708 2.813,0.875 0.5,0.167 9 false Control 0.323,1.813 1.052,2.01 0.729,0.198 8 false Temp. Setting 0.333,2.521 1.021,2.708 0.688,0.188 8 false Sensor Input 0.333,3.26 1.052,3.427 0.719,0.167 8 false Switch Input 1.781,1 2.49,1.292 0.708,0.292 8 false Neural Network 1.781,1.396 2.49,1.677 0.708,0.281 8 false Target Outlet Temp. 1.781,1.781 2.49,2.031 0.708,0.25 6 false Amount of Sunlight Correction 1.792,2.177 2.438,2.458 0.646,0.281 7 false Target Airflow Volume 1.792,2.625 2.469,2.792 0.677,0.167 8 false Outlet Mode 1.792,3.135 2.458,3.313 0.667,0.177 8 false Inlet Mode 1.792,3.49 2.479,3.667 0.688,0.177 8 false Compressor 2.771,1.563 3.531,1.854 0.76,0.292 8 false Temp. Control Correction 2.76,2.125 3.563,2.5 0.802,0.375 7 false Various Types of Airflow Volume Corrections 2.76,2.583 3.563,2.969 0.802,0.385 7 false Various Types of Mode Corrections 2.76,3.083 3.563,3.396 0.802,0.313 8 false Various Types of Corrections 3.969,1.167 4.677,1.458 0.708,0.292 8 false Output Processing 3.958,1.573 4.708,1.875 0.75,0.302 8 false Air Mix Control Damper 3.958,2.177 4.698,2.365 0.74,0.188 8 false Blower Motor 3.969,2.615 4.688,2.906 0.719,0.292 8 false Mode Control Damper 3.969,3.063 4.688,3.385 0.719,0.323 7 false Air Inlet Control Damper 3.99,3.5 4.667,3.656 0.677,0.156 8 false Compressor 5.583,1.104 6.875,1.313 1.292,0.208 9 false Intermediate Layer 5.26,1.427 5.969,1.604 0.708,0.177 9 false Input Layer 6.354,1.427 7.156,1.604 0.802,0.177 9 false Output Layer 4.844,1.656 5.375,1.99 0.531,0.333 9 false Ambient Temp. 6.302,3.208 7.125,3.552 0.823,0.344 9 false Target Output Temp. 4.823,2.156 5.406,2.448 0.583,0.292 8 false Amount of Sunlight 4.938,2.698 5.354,3.052 0.417,0.354 9 false Room Temp. 0.854,3.979 3.094,4.208 2.24,0.229 10 false : Neural Network Operation Range



c.

Pollen Removal Mode Control

i.

When the pollen removal mode switch is pressed, the air conditioner ECU changes to the recirculation mode and face mode. This allows the air conditioner to direct clean air, which has passed through the clean air filter, to the face areas. Thus, the air conditioner removes pollen and captures it in the clean air filter.


ii.

From the pollen removal mode control, the air conditioner automatically resumes normal automatic mode control after 3 minutes at normal temperatures, or after 1 minute when the ambient temperature is low (5°C maximum).

Example of Operation in Warm-up
Y209790E01
5,0.208 6.625,0.417 1.625,0.208 10 false : In pollen removal mode 5,0.417 6.781,0.625 1.781,0.208 10 false : In normal automatic mode 4.948,0.74 6.5,0.938 1.552,0.198 10 false Normal Automatic Mode 3.188,0.74 4.615,0.938 1.427,0.198 10 false Pollen Removal Mode 0.417,1.146 1.438,1.521 1.021,0.375 10 false Air Inlet Control Damper 1.677,1.083 2.24,1.26 0.563,0.177 10 false RECIRC 1.719,1.292 2.25,1.469 0.531,0.177 10 false FRESH 1.813,1.49 2.24,1.677 0.427,0.188 10 false FACE 1.594,1.688 2.25,1.865 0.656,0.177 10 false BI-LEVEL 1.823,1.885 2.25,2.063 0.427,0.177 10 false FOOT 1.906,2.073 2.25,2.271 0.344,0.198 10 false High 1.99,2.271 2.25,2.448 0.26,0.177 10 false M2 2,2.469 2.26,2.635 0.26,0.167 10 false M1 1.938,2.656 2.26,2.844 0.323,0.188 10 false Low 1.927,2.875 2.26,3.042 0.333,0.167 10 false OFF 0.396,1.656 1.302,2.063 0.906,0.406 10 false Mode Control Damper 0.417,2.479 1.281,2.896 0.865,0.417 10 false Blower Motor Level 2.938,3.365 3.094,3.563 0.156,0.198 10 false 0 3.542,3.365 3.698,3.563 0.156,0.198 10 false 1 4.146,3.365 4.302,3.563 0.156,0.198 10 false 2 4.74,3.375 4.896,3.573 0.156,0.198 10 false 3 3.729,3.563 4.229,3.729 0.5,0.167 10 false Time 5.688,3.531 6.177,3.719 0.49,0.188 10 false (Min.)



d.

PTC Heater Operating Conditions

i.

The ON/OFF function of the PTC heater is controlled by the air conditioner ECU in accordance with the water temperature, engine speed, air mix setting, ambient temperature and electrical load (alternator power ratio). For example, the number of the operating PTC heaters varies with the water temperature as in the graph below.

Heating Value Pattern
Y209876E01
4.792,1.375 5.25,1.573 0.458,0.198 10 false (°C) 1.792,0.146 2.073,0.344 0.281,0.198 10 false (W) 1.792,0.385 2.083,0.542 0.292,0.156 10 false 600 1.792,0.594 2.083,0.792 0.292,0.198 10 false 450 1.792,0.802 2.094,0.969 0.302,0.167 10 false 300 1.938,1.031 2.094,1.229 0.156,0.198 10 false 0 0.615,0.594 1.625,0.802 1.01,0.208 10 false Heating Value 2.813,1.542 4.177,1.708 1.365,0.167 10 false Water Temperature 2.51,1.354 2.813,1.542 0.302,0.188 10 false 65 2.938,1.354 3.177,1.51 0.24,0.156 10 false 70 3.385,1.344 3.635,1.521 0.25,0.177 10 false 75 3.844,1.344 4.073,1.521 0.229,0.177 10 false 80




CONSTRUCTION


a.

Air Conditioner Control Panel

i.

The front air conditioner control panel is push type for LHD models. The air conditioner is operated by using the push button.


ii.

The front air conditioner control panel is capacitive type for RHD models. The air conditioner is operated by using the capacitive type touch switches.


iii.

The front air conditioner control panel has been located in the center of the instrument panel and the rear air conditioner control panel has been located in the center of the roof to ensure excellent ease of use.


iv.

The front air conditioner control panel and rear air conditioner control panel (automatic type) use an LCD (Liquid Crystal Display) to display the set temperature, air outlet mode and blower speed to ensure excellent visibility.

Front Air Conditioner Control Panel (LHD Models)
Y209930

Front Air Conditioner Control Panel (RHD Models)
Y210048

Rear Air Conditioner Control Panel (Automatic Type (Rear Cooler and Heater))
Y209872

Rear Air Conditioner Control Panel (Manual Type (Rear Cooler))
Y209873



b.

Air Conditioner and Blower Units

i.

Front Air Conditioner Unit

·

A semi-center location front air conditioner unit, in which the evaporator and heater core are placed in the vehicle's longitudinal direction, is used. As a result, the front air conditioner unit is made compact and lightweight.

Y209874C01
0.594,0.833 0.729,0.833 0.729,0.833 1.24,1.427 true 0.625,3.083 0.76,3.083 0.76,3.083 1.771,2.667 true 3.698,0.844 3.833,0.844 3.833,0.844 4.271,1.781 true 4.844,2.542 5.583,3.094 5.583,3.094 5.708,3.094 true 0.438,0.76 0.75,0.917 0.313,0.156 10 false *1 0.438,3 0.75,3.156 0.313,0.156 10 false *2 1.438,3.333 1.75,3.49 0.313,0.156 10 false *a 5.188,3.344 5.5,3.5 0.313,0.156 10 false *b 4.771,0.448 5.083,0.604 0.313,0.156 10 false *c 3.521,0.76 3.833,0.917 0.313,0.156 10 false *1 5.75,3 6.063,3.156 0.313,0.156 10 false *2 1.229,0.708 1.542,0.865 0.313,0.156 10 false *c
*1 Evaporator *2 Heater Core
*a Side View *b Top View
*c Front - -




ii.

Rear Air Conditioner Unit

·

The rear air conditioner unit is located inside the right quarter trim. The evaporator is laid out horizontally in this unit in order to direct the airflow smoothly upward. Full air mix type air mix doors are used for temperature adjustment, and a laminate slide type mode control door is used to make the rear air conditioner unit compact and lightweight.

Y209875C01
1.458,1.313 1.656,1.313 1.656,1.313 3.708,2.031 true 1.563,2.5 2.698,2.5 true 2.667,4.01 2.865,4.01 2.865,4.01 3.771,3.25 true 4.115,2.719 5.198,2.219 5.198,2.219 5.385,2.219 true 4.479,3.292 4.823,4.198 4.823,4.198 5.01,4.198 true 2.063,3.042 2.26,3.042 2.26,3.042 3.74,2.615 true 1.302,1.24 1.615,1.396 0.313,0.156 10 false *1 1.385,2.427 1.698,2.583 0.313,0.156 10 false *2 5.417,2.135 5.729,2.292 0.313,0.156 10 false *3 2.49,3.938 2.802,4.094 0.313,0.156 10 false *4 5.031,4.115 5.344,4.271 0.313,0.156 10 false *5 3.75,1.281 4.063,1.438 0.313,0.156 10 false *a 4.771,1.885 5.083,2.042 0.313,0.156 10 false *b 1.896,2.969 2.208,3.125 0.313,0.156 10 false *5
*1 Mode Control Door (Laminate Slide Type) *2 Blower Unit
*3 Heater Core *4 Evaporator
*5 Air Mix Door - -
*a Foot *b Face




iii.

Partial Recirculation System

·

A partial recirculation system is provided on the China models and the RHD models for other destinations.

·

This system has an air inlet control door (sub) in the cabin side of the air inlet duct. Thus, it is able to cycle a small volume of recirculated air even in the FRESH mode, thus ensuring heating and air conditioning performance. When the blower switch is ON, the suction force of the blower fan opens this air inlet control door (sub).

Y209797C01
5.885,0.719 6.115,0.219 6.115,0.219 6.25,0.219 false 6.385,1.115 6.51,0.948 6.51,0.948 6.646,0.948 false 6.146,1.479 6.25,1.479 6.25,1.479 6.375,1.635 true 6.271,0.115 6.583,0.271 0.313,0.156 10 false *1 3.698,0.396 4.01,0.552 0.313,0.156 10 false *a 5.042,0.333 5.354,0.49 0.313,0.156 10 false *b 6.323,0.5 6.635,0.656 0.313,0.156 10 false *c 6.667,0.844 6.979,1 0.313,0.156 10 false *2 5.979,1.365 6.292,1.521 0.313,0.156 10 false *3 5.646,2.573 5.854,2.792 0.208,0.219 10 false *d 6.844,1.552 7.156,1.708 0.313,0.156 10 false *c
*1 Air Inlet Control Door *2 Air Inlet Duct
*3 Air Inlet Control Door (sub) - -
*a Front *b FRESH
*c RECIRC *d Blower Fan





c.

Evaporator

i.

An RS (Revolutionary super-slim Structure) evaporator is used. Placing the tanks at the top and the bottom of the evaporator and adopting a micropore tube construction have realized the following effects:

·

The heat exchanging efficiency is improved.

·

The temperature distribution is made more uniform.

·

The evaporator is made thinner: 58 mm (2.3 in.)→ 38 mm (1.5 in.)

·

The evaporator body has been coated with a type of resin that contains an antibacterial agent in order to minimize the source of foul odor and the propagation of bacteria. The substrate below this coating consists of a chromate-free layer to help protect the environment.

Y209960C01
1.833,2.938 1.833,3.323 true 3.521,2.135 3.521,2.573 true 2.396,2.427 2.542,2.427 2.542,2.427 2.542,2.917 true 5.125,1.813 5.406,1.406 5.406,1.406 5.542,1.406 true 6.177,1.854 6.427,1.5 6.427,1.5 6.563,1.5 true 6.167,2.156 6.594,2.156 true 5.573,2.5 5.573,2.781 true 1.677,0.969 1.823,0.969 1.823,0.969 1.823,1.458 true 3.115,0.948 3.26,0.948 3.26,0.948 3.26,1.438 true 1.5,0.865 1.813,1.021 0.313,0.156 10 false *a 2.958,0.844 3.271,1 0.313,0.156 10 false *b 2.479,2.906 2.792,3.063 0.313,0.156 10 false *c 5.573,1.323 5.885,1.479 0.313,0.156 10 false *d 6.594,1.396 6.906,1.552 0.313,0.156 10 false *e 6.625,2.073 6.938,2.229 0.313,0.156 10 false *f 5.5,2.792 5.74,3.031 0.24,0.24 10 false *g 1.75,3.333 2.063,3.49 0.313,0.156 10 false *a 3.448,2.625 3.76,2.781 0.313,0.156 10 false *c
*a Tank *b Cooling Fin
*c Micropore Tube *d Antibacterial Agent
*e Nylon Layer *f Chromate-free Layer
*g Aluminum Matrix - -





d.

SFA-II Heater Core (SFA-II: Straight Flow Aluminum-II)

i.

The SFA-II heater core has been made more compact and higher performance by making the core section finer and improving the shapes of the tank section and flow section. Also, the environment is considered. By using aluminum as the material, the amount of the environmental burden disposal (lead) is reduced.

Y209959C01
2.365,1.198 2.677,1.354 0.313,0.156 10 false *a 2.667,2.104 2.979,2.26 0.313,0.156 10 false *b
*a OUT *b IN




e.

PTC (Positive Temperature Coefficient) Heater

i.

On the China models, a PTC (Positive Temperature Coefficient) heater is used to improve the heating performance.


ii.

The PTC heater is located above the heater core in the front air conditioner unit.


iii.

The PTC heater consists of a PTC element, aluminum fin, and brass plate. When current is applied to the PTC element, it generates heat to warm the air that passes through the unit.

Y209761C01
1.792,0.375 1.927,0.375 1.927,0.375 2.271,0.823 true 4.094,1.729 4.229,1.729 4.229,1.729 4.583,1.083 true 5.427,1.281 5.719,1.74 5.719,1.74 5.885,1.74 true 5.75,0.385 6.083,0.167 6.083,0.167 6.25,0.167 true 1.625,0.302 1.938,0.458 0.313,0.156 10 false *1 6.271,0.073 6.583,0.229 0.313,0.156 10 false *a 3.917,1.656 4.229,1.813 0.313,0.156 10 false *b 5.906,1.656 6.219,1.813 0.313,0.156 10 false *c
*1 PTC Heater - -
*a Brass Plate *b PTC Element
*c Aluminum Fin - -




f.

BUS Connector

i.

A BUS connector is used in the wire harness connection that connects the servomotor with the air conditioner ECU.

Front Air Conditioner Unit
Y209973C01
1.427,0.427 1.51,0.427 1.51,0.427 1.51,0.76 true 3.052,0.417 3.135,0.417 3.135,0.417 3.135,0.688 true 4,2.406 4.271,2.406 true 4.625,3.125 4.896,3.125 true 1.542,2.677 1.656,2.677 1.656,2.677 1.656,2.479 true 1.271,0.333 1.583,0.49 0.313,0.156 10 false *a 1.375,2.583 1.688,2.74 0.313,0.156 10 false *b 1.25,1.083 1.563,1.24 0.313,0.156 10 false *c 2.844,1.104 3.156,1.26 0.313,0.156 10 false *d 5.802,0.313 6.115,0.469 0.313,0.156 10 false *e 4.052,2.146 4.25,2.313 0.198,0.167 10 false *f 4.688,3.292 4.938,3.521 0.25,0.229 10 false *g 2.896,0.323 3.208,0.479 0.313,0.156 10 false *a 3.844,2.313 4.156,2.469 0.313,0.156 10 false *a 4.917,3.042 5.229,3.198 0.313,0.156 10 false *a
*a BUS Connector *b Evaporator Temp. Sensor
*c To Air Mix Servomotor (For Driver) *d To Air Inlet Servomotor
*e To Air Conditioner ECU *f To Air Vent Servomotor
*g To Air Mix Servomotor (For Front Passenger) - -


Rear Air Conditioner Unit
Y209877C01
1.063,0.448 1.167,0.448 1.167,0.448 1.167,0.677 true 3.698,0.448 3.802,0.448 3.802,0.448 3.802,0.656 true 4.354,2.552 4.49,2.552 4.49,2.552 4.49,2.292 true 3.542,0.354 3.854,0.51 0.313,0.156 10 false *a 4.198,2.469 4.51,2.625 0.313,0.156 10 false *b 1.354,1.125 1.667,1.281 0.313,0.156 10 false *c 3.75,1.115 4.063,1.271 0.313,0.156 10 false *d 5.896,0.292 6.208,0.448 0.313,0.156 10 false *e 0.917,0.354 1.229,0.51 0.313,0.156 10 false *a
*a BUS Connector *b Evaporator Temp. Sensor
*c To Air Vent Servomotor *d To Air Mix Servomotor
*e To Air Conditioner ECU - -



ii.

The BUS connector has a built-in communication / drive IC, which communicates with each servomotor and sir conditioner ECU, actuates the servomotor, and has a position detection function. This realizes a more lightweight construction and reduce the number of wires.

With BUS Connector
Y209974C01
4.073,0.177 4.167,0.177 4.167,0.177 4.167,0.438 true 4.25,0.542 4.25,0.177 4.25,0.177 4.354,0.177 false 1.156,0.302 1.469,0.458 0.313,0.156 10 false *a 1.656,0.604 1.969,0.76 0.313,0.156 10 false *b 1.677,1 1.99,1.156 0.313,0.156 10 false *c 3.906,0.083 4.219,0.24 0.313,0.156 10 false *d 4.375,0.083 4.688,0.24 0.313,0.156 10 false *e 5.125,0.583 5.438,0.74 0.313,0.156 10 false *f
*a Air Conditioner ECU *b Communication IC
*c CPU *d BUS Connector
*e Communication / Drive IC *f Servomotor


Without BUS Connector
Y209975C01
1.135,0.323 1.448,0.479 0.313,0.156 10 false *a 1.271,0.792 1.583,0.948 0.313,0.156 10 false *b 2.031,0.521 2.344,0.677 0.313,0.156 10 false *c 2.052,1.094 2.365,1.25 0.313,0.156 10 false *c 5.281,0.51 5.594,0.667 0.313,0.156 10 false *d
*a Air Conditioner ECU *b CPU
*c Drive IC *d Servomotor




g.

Servomotor

i.

The pulse pattern type servomotor consists of a printed-circuit board and servomotor. The printed-circuit board has three contact points, and transmits the two ON/OFF signals with different pulse phases to the bus connector. The bus connector detects the damper position and movement direction with these signals, and transmits the results to the air conditioner ECU.

Y209976E01
1.427,0.135 1.531,0.135 1.531,0.135 1.781,0.667 true 0.823,2.427 0.938,2.427 0.938,2.427 1.219,1.531 true 1.594,2.604 1.479,2.604 1.479,2.604 1.302,1.771 true 6.021,0.281 6.208,0.281 true 5.854,0.771 5.854,0.906 5.854,0.906 6.198,0.906 true 0.49,0.052 1.583,0.24 1.094,0.188 10 false Contact Points 2.646,0.656 2.802,0.854 0.156,0.198 10 false A 2.646,0.813 2.802,1.01 0.156,0.198 10 false B 2.635,0.948 3.094,1.146 0.458,0.198 10 false GND 0.073,2.344 0.802,2.74 0.729,0.396 10 false Conduction Portion 1.625,2.531 2.979,2.708 1.354,0.177 10 false Printed-circuit Board 3.01,0.021 4.01,0.188 1,0.167 10 false Contact Points 3.24,0.219 3.396,0.417 0.156,0.198 10 false A 3.24,0.438 3.396,0.635 0.156,0.198 10 false B 3.042,0.646 3.5,0.844 0.458,0.198 10 false GND 3.302,1.281 3.531,1.448 0.229,0.167 10 false Hi 3.302,1.49 3.531,1.677 0.229,0.188 10 false Lo 3.302,1.781 3.51,1.958 0.208,0.177 10 false Hi 3.292,2 3.542,2.167 0.25,0.167 10 false Lo 2.958,1.396 3.115,1.594 0.156,0.198 10 false A 2.969,1.885 3.125,2.083 0.156,0.198 10 false B 4.51,2.479 5.313,2.656 0.802,0.177 10 false 1 Rotation 6.25,0.198 7.031,0.552 0.781,0.354 10 false Conduction Portion 6.25,0.823 7.156,1.24 0.906,0.417 10 false Printed-circuit Board



h.

Clean Air Filter

i.

A clean air filter (high efficiency type) is used to remove dust, pollen, and other micron particles from air entering from outside the vehicle to provide a comfortable cabin of clean air. The clean air filter is installed in the upper section of the blower fan for easy replacement without the need for tools by removing the one-touch clip in the glove box, making this easy to service.

Y209823C01
1.698,1.781 1.833,1.781 1.833,1.781 3.26,1.49 true 1.542,1.698 1.854,1.854 0.313,0.156 10 false *1
*1 Clean Air Filter - -


HINT:
·

The replacement intervals are shown in the table on the right.

Destination Replacement Interval
Normal Condition Dusty Condition
Australia 30000 km or 18500 miles 15000 km or 9000 miles
G.C.C. Countries
General Countries
China
20000 km or 12500 miles

·

Replace the clean air filter after the power source mode is selected to OFF.





i.

Condenser

i.

The new models use a sub-cool condenser. This is a multi-flow condenser consisting of three portions: a condensing portion, a super-cooling portion and a gas-liquid separator (modulator) all integrated together. This condenser uses a sub-cool cycle for its cooling cycle system to improve heat-exchanging efficiency.


ii.

In the sub-cool cycle, after the refrigerant passes through the condensing portion of the condenser, both the liquid refrigerant and the gaseous refrigerant that could not be liquefied are cooled again in the super-cooling portion. Thus, the refrigerant is sent to the evaporator in an almost completely liquefied state.

Y209838C01
2.083,0.167 2.188,0.167 2.188,0.167 2.354,0.385 true 3.438,0.51 3.625,0.167 3.625,0.167 3.75,0.167 true 4.688,0.583 4.885,0.333 4.885,0.333 5,0.333 true 5.74,1.24 5.563,0.594 5.563,0.594 5.438,0.594 true 5.344,2.531 5.448,2.531 5.448,2.531 5.656,1.656 true 3.063,2.531 3.167,2.531 3.167,2.531 3.271,2.188 true 1.906,0.083 2.219,0.24 0.313,0.156 10 false *a 3.771,0.083 4.083,0.24 0.313,0.156 10 false *b 5.021,0.24 5.333,0.396 0.313,0.156 10 false *c 5.281,0.5 5.594,0.656 0.313,0.156 10 false *d 5.177,2.427 5.49,2.583 0.313,0.156 10 false *e 2.938,2.448 3.25,2.604 0.313,0.156 10 false *f 0.917,0.906 1.208,1.125 0.292,0.219 10 false *g 0.917,2.042 1.229,2.198 0.313,0.156 10 false *h
*a Multi-flow Condenser *b Condensing Portion
*c Modulator *d Desiccant
*e Filter *f Super-cooling Portion
*g Gaseous Refrigerant *h Liquid Refrigerant


HINT:

The point at which the air bubbles disappear in the refrigerant of the sub-cool cycle is lower than the proper amount of refrigerant with which the system must be filled. Therefore, if the system is recharged with refrigerant based on the point at which the air bubbles disappear, the amount of refrigerant would be insufficient. As a result, the cooling performance of the system will be affected. If the system is overcharged with refrigerant, this will also lead to a reduced performance. For the proper method of verifying the amount of the refrigerant and to recharge the system with refrigerant, see Repair Manual.

Y209933E01
0.927,0.844 1.865,1.063 0.938,0.219 10 false High Pressure 2.854,1.417 4.688,1.604 1.833,0.188 10 false Properly Recharged Amount 2.948,2.448 5.073,2.656 2.125,0.208 10 false Point in which Bubbles Disappear 4.104,2.979 5.542,3.188 1.438,0.208 10 false Amount of Refrigerant




j.

A/C Compressor

i.

An A/C compressor is a continuously variable capacity type in which its capacity varies in accordance with the cooling load of the air conditioner.

·

This compressor consists of the shaft, lug plate, piston, shoe, crank chamber, cylinder, and solenoid control valve.

·

The solenoid control valve that adjusts the suction pressure so that the suction pressure can be controlled as desired is provided.

·

The plastic DL (Damper Limiter) type A/C pulley is used.

·

On the models for the G.C.C. countries, the A/C compressor contains a flow control valve with a built-in internal Ps valve. It has the dual purpose of ensuring the proper cooling performance during high-load, high-speed operation and improving the control performance of the compressor. In addition, the suction resistance has been reduced by enlarging the suction passage, thus improving discharge capacity.

·

A rotary valve type is used to suction refrigerant gas into the cylinder.

Y209878C01
2.083,0.25 2.25,0.25 2.25,0.25 2.542,0.781 true 4,0.25 3.865,0.25 3.865,0.25 3.698,0.885 true 5.406,1.885 4.854,1.885 true 1.667,1.458 2.417,1.458 true 2.917,2.583 3.01,2.583 3.01,2.583 3.188,1.719 true 3.833,2 3.833,2.5 true 4.219,2 4.219,2.5 true 2.99,0.24 3.156,0.24 3.156,0.24 3.354,0.875 true 1.917,0.167 2.229,0.323 0.313,0.156 10 false *a 1.5,1.365 1.813,1.521 0.313,0.156 10 false *b 2.813,0.156 3.125,0.313 0.313,0.156 10 false *c 4.021,0.167 4.333,0.323 0.313,0.156 10 false *d 2.76,2.5 3.073,2.656 0.313,0.156 10 false *e 3.771,2.5 4.083,2.656 0.313,0.156 10 false *f 4.156,2.5 4.427,2.729 0.271,0.229 10 false *g 5.417,1.792 5.708,1.969 0.292,0.177 10 false *h
*a A/C Pulley *b Shaft
*c Crank Chamber *d Shoe
*e Lug Plate *f Piston
*g Cylinder *h Solenoid Control Valve





k.

Plastic DL Type A/C Pulley

i.

This pulley contains dampers to absorb the torque fluctuations of the engine and a limiter mechanism to protect the drive belt in case the compressor locks. In the event that the compressor locks, the limiter mechanism causes the spoke portion of the pulley to break, thus separating the pulley from the compressor. To reduce weight, the pulley portion is made of plastic.

Y209950C01
1.375,1.104 1.521,1.104 1.521,1.104 2.073,2.292 true 0.677,2.438 1.76,2.438 true 2.188,2.49 3.094,3.583 3.094,3.583 3.25,3.583 true 0.927,3.427 1.063,3.427 1.063,3.427 1.563,2.823 true 4.125,1.781 4.719,1.781 true 4.625,1.073 4.771,1.073 4.771,1.073 4.771,1.479 true 1.99,3.896 2.302,4.052 0.313,0.156 10 false *a 0.76,3.344 1.073,3.5 0.313,0.156 10 false *c 2.063,0.99 2.375,1.146 0.313,0.156 10 false *d 4.458,0.958 4.771,1.115 0.313,0.156 10 false *e 3.958,1.708 4.271,1.865 0.313,0.156 10 false *c 1.177,1.021 1.49,1.177 0.313,0.156 10 false *b 0.51,2.365 0.823,2.521 0.313,0.156 10 false *b 3.271,3.49 3.583,3.646 0.313,0.156 10 false *b
*a Limiter Mechanism *b Spoke Portion
*c Damper *d Rotate Direction
*e Pulley Portion (Plastic) - -





OPERATION


a.

MODE POSITION AND DAMPER OPERATION

i.

Front Unit

Y209772E01
1.167,2.156 1.354,2.156 1.354,2.156 1.354,1.99 true 2.604,1.729 3.198,0.448 3.198,0.448 3.292,0.448 true 3.583,3.177 3.802,3.656 3.802,3.656 3.927,3.656 true 2.083,2.698 2.167,2.698 2.167,2.698 2.167,2.052 true 1.792,0.271 2.802,0.448 1.01,0.177 10 false Front Defroster 3.323,0.344 4.188,0.542 0.865,0.198 10 false Heater Core 0.635,0.708 1.167,0.885 0.531,0.177 10 false FRESH 1.635,0.646 2.229,0.802 0.594,0.156 10 true RECIRC 0.323,2.052 1.188,2.24 0.865,0.188 10 false Blower Motor 1.396,2.594 2.083,2.781 0.688,0.188 10 false Evaporator 0.865,3.073 1.833,3.271 0.969,0.198 10 false Side Register 1.531,3.375 2.646,3.708 1.115,0.333 10 false Footwell Register Duct 2.708,3.385 3.594,3.76 0.885,0.375 10 false Rear Footwell Register Duct 3.979,3.573 5.031,3.802 1.052,0.229 10 false Center Register 4.021,3.354 5.573,3.573 1.552,0.219 10 false Footwell Register Duct 5.594,3.042 6.583,3.24 0.99,0.198 10 false Side Register 0.99,1.063 1.146,1.26 0.156,0.198 10 false B 1.688,1.042 1.844,1.24 0.156,0.198 10 false A 1.865,1.188 2.438,1.354 0.573,0.167 10 true RECIRC 2.25,0.698 2.406,0.896 0.156,0.198 10 false F 2.354,0.688 2.51,0.833 0.156,0.146 10 false G 2.469,0.76 2.625,0.917 0.156,0.156 10 true H 2.51,0.906 2.604,1.083 0.094,0.177 10 false I 2.135,1.5 2.281,1.667 0.146,0.167 10 true C 2.135,1.74 2.281,1.906 0.146,0.167 10 true D 2.323,1.875 2.479,2.073 0.156,0.198 10 false E 2.958,1.135 3.115,1.333 0.156,0.198 10 false S 3.083,1.208 3.24,1.406 0.156,0.198 10 true R 3.104,1.365 3.26,1.563 0.156,0.198 10 false Q 2.875,1.76 3.031,1.938 0.156,0.177 10 true X 2.771,1.844 2.927,2.01 0.156,0.167 10 false Y 2.719,1.99 2.865,2.177 0.146,0.188 10 false Z 3.448,2.188 3.604,2.375 0.156,0.188 10 true K 3.146,2.396 3.302,2.563 0.156,0.167 10 false J 3.635,2.198 3.771,2.344 0.135,0.146 10 true P 3.948,2.375 4.115,2.542 0.167,0.167 10 false O 3.354,2.802 3.521,2.958 0.167,0.156 10 false L 3.396,2.969 3.542,3.115 0.146,0.146 10 true N 3.521,3 3.677,3.198 0.156,0.198 10 false M

HINT:

This illustration is a model diagram showing the damper positions in each mode. The parts layout and the number of the dampers in the illustration are different from those of the actual system.


Control Damper Operation Position Damper Position Operation
Air Inlet Control Damper FRESH A Brings in fresh air.
RECIRC B Recirculates internal air.
Air Mix Control Damper MAX COLD - MAX HOT Temp. Setting (Auto A/C): 18 °C (64.4 °F) - 32 °C (89.6 °F) C-E Varies the mixture ratio of the fresh air and the recirculation air in order to regulate the temperature continuously from HOT to COLD.
Mode Control Damper
Y129006

DEF F, K, L, P, S, X Defrosts the windshield through the front defroster and side register.
Y129007

FOOT/DEF G, K, L, P, Q, Y Defrosts the windshield through the front defroster and side register, while air is also blown out from the footwell register duct and rear footwell register duct.
Y129008

FOOT H, K, L, P, Q, Z Air blows out of the footwell register duct, rear footwell register duct, and side register. In addition, air blows out slightly from the front defroster.
Y129009

BI-LEVEL I, K, N, P, R, Z Air blows out of the center register, side register, footwell register duct and rear footwell register duct.
Y129010

FACE I, J, M, O, S, X Air blows out of the center register and side register.


ii.

Rear Unit

Y209773E01
1.396,2.802 1.542,2.802 1.542,2.802 1.979,2.021 false 3.26,4.052 3.406,4.052 3.406,4.052 4.021,2.969 false 2.583,0.333 2.729,0.333 2.729,0.333 3.094,0.896 true 1.802,0.24 2.604,0.427 0.802,0.188 10 false Heater Core 3.385,0.135 4.281,0.49 0.896,0.354 10 false Rear Footwell Register 4.917,0.365 5.896,0.74 0.979,0.375 10 false Rear Roof Side Register 0.552,2.688 1.531,2.906 0.979,0.219 10 false Blower Motor 2.583,3.948 3.385,4.135 0.802,0.188 10 false Evaporator 3.385,0.802 3.542,1 0.156,0.198 10 false C 3.729,0.938 3.885,1.135 0.156,0.198 10 false B 4.167,1.042 4.323,1.24 0.156,0.198 10 false A 4.771,1.417 4.927,1.615 0.156,0.198 10 false C 5.177,1.802 5.333,2 0.156,0.198 10 false B 5.792,2.146 5.948,2.344 0.156,0.198 10 false A 3.552,1.521 3.708,1.719 0.156,0.198 10 false E 3.542,1.833 3.698,2.031 0.156,0.198 10 false D 4.438,2.594 4.594,2.792 0.156,0.198 10 false D 5.229,2.802 5.385,3 0.156,0.198 10 false E

Control Damper Control Position Damper Position Operation
Mode Control Door
Y129010

FACE A Air blows out of the rear roof side register.
Y129009

BI-LEVEL B Air blows out of the rear roof side register and the rear footwell register.
Y129008

FOOT C Air blows out of the rear footwell register.
Air Mix Control Damper MAX COLD - MAX HOT Temp. Setting (Auto A/C): 18 °C (64.4 °F) - 32 °C (89.6 °F) D-E Varies the mixture ratio of the fresh air and the recirculation air in order to regulate the temperature continuously from HOT to COLD.



b.

A/C Compressor

i.

The crank chamber is connected to the suction passage. A solenoid control valve is provided between the suction passage (low pressure) and the discharge passage (high pressure).


ii.

The solenoid control valve operates under duty cycle control in accordance with the signals from the air conditioner ECU.

Y209977C01
1.365,1.302 1.594,1.5 0.229,0.198 10 false *a 2.51,1.302 2.823,1.458 0.313,0.156 10 false *b 3.833,0.313 4.146,0.469 0.313,0.156 10 false *c 3.677,1.74 3.99,1.896 0.313,0.156 10 false *d 5.729,0.531 6.042,0.688 0.313,0.156 10 false *e 5.01,1.698 5.323,1.854 0.313,0.156 10 false *f 4.99,2.052 5.198,2.271 0.208,0.219 10 false *g 5.74,3.021 6.052,3.177 0.313,0.156 10 false *h 2.063,2.75 2.375,2.906 0.313,0.156 10 false *b
*a Crank Chamber *b Piston
*c Suction *d Discharge
*e Air Conditioner ECU *f Suction Pressure
*g Discharge Pressure *h Solenoid Control Valve



iii.

When the solenoid control valve closes (solenoid coil is energized), a difference in pressure is created and the pressure in the crank chamber decreases. Then, the pressure that is applied to the right side of the piston becomes greater than the pressure that is applied to the left side of the piston. This compresses the spring and tilts the lug plate. As a result, the piston stroke increases and the discharge capacity increases.

Y209978C01
0.917,2.281 1.229,2.438 0.313,0.156 10 false *a 2.813,3.438 3.125,3.594 0.313,0.156 10 false *b 3.771,0.323 4.083,0.479 0.313,0.156 10 false *c 3.615,1.771 3.927,1.927 0.313,0.156 10 false *d 5.74,0.531 6.052,0.688 0.313,0.156 10 false *e 5.01,2.125 5.323,2.281 0.313,0.156 10 false *f 5.729,3.094 5.948,3.344 0.219,0.25 10 false *g
*a Crank Chamber Pressure + Spring Force *b Piston Stroke: Large
*c Suction *d Discharge
*e Air Conditioner ECU *f Discharge Pressure
*g Solenoid Control Valve - -



iv.

When the solenoid control valve opens (solenoid coil is not energized), the difference in pressure disappears. Then, the pressure that is applied to the left side of the piston becomes the same as the pressure that is applied to the right side of the piston. Thus, the spring elongates and eliminates the tilt of the lag plate. As a result, there is no piston stroke and the discharge capacity decreases.

Y209979C01
0.958,2.208 1.271,2.365 0.313,0.156 10 false *a 2.958,3.375 3.271,3.531 0.313,0.156 10 false *b 3.771,0.281 4.083,0.438 0.313,0.156 10 false *c 3.625,1.729 3.938,1.885 0.313,0.156 10 false *d 5.719,0.5 6.031,0.656 0.313,0.156 10 false *e 5,1.698 5.313,1.854 0.313,0.156 10 false *f 4.979,2.031 5.188,2.281 0.208,0.25 10 false *g 5.771,3.01 6.073,3.219 0.302,0.208 10 false *h
*a Crank Chamber Pressure + Spring Force *b Piston Stroke: Small
*c Suction *d Discharge
*e Air Conditioner ECU *f Suction Pressure
*g Discharge Pressure *h Solenoid Control Valve



v.

Flow Control Valve with Built-in Internal Ps Valve

·

Ordinarily, the internal Ps valve does not operate because the solenoid control valve controls the air conditioner. The internal Ps valve operates to help reduce the discharge capacity in order to reduce the load on the compressor only if the compressor speed has increased suddenly or started at a high speed, or if the thermal load has changed suddenly.

Y209879C01
6.188,3.646 6.323,3.531 6.323,3.531 6.438,3.531 false 0.833,2.656 1.146,2.813 0.313,0.156 10 false *a 3.781,0.646 4.094,0.802 0.313,0.156 10 false *b 3.625,2.135 3.938,2.292 0.313,0.156 10 false *c 3.417,4.021 3.729,4.177 0.313,0.156 10 false *d 5.865,0.802 6.177,0.958 0.313,0.156 10 false *e 5.063,2.083 5.375,2.24 0.313,0.156 10 false *f 5.063,2.458 5.354,2.708 0.292,0.25 10 false *g 5.875,4.052 6.188,4.208 0.313,0.156 10 false *h 6.448,3.438 6.76,3.594 0.313,0.156 10 false *d
*a Crank Chamber Pressure + Spring Force *b Suction
*c Discharge *d Internal Ps Valve
*e Air Conditioner ECU *f Suction Pressure
*g Discharge Pressure *h Solenoid Control Valve





c.

No. 2 Ion Generator Sub-Assembly

i.

The No. 2 ion generator sub-assembly operates according to the operation of the blower motor when the ion generator switch (air purifier switch assembly) is on.


ii.

The No. 2 ion generator sub-assembly emits "nanoe" ions that are electrically charged and encapsulated with water. The ions are discharged into the cabin through the driver side vent to provide skin-friendly clean air.*

*: According to temperature and humidity conditions, fan speed and air outlet mode selected, the No. 2 ion generator sub-assembly may not operate at full capacity.

CAUTION:

Do not attempt to disassemble or repair the No. 2 ion generator sub-assembly because it contains high voltage parts.


NOTICE:

Do not insert anything into the "nanoe" vent, attach anything to it, or use sprays around the "nanoe" vent on the driver side. These things may cause the ion generator sub-assembly not to work properly.


HINT:
·

When the No. 2 ion generator sub-assembly operates, a small amount of ozone is emitted and may be faintly smelled in some situations. However, this is approximately the same as the amount that already exists in nature, such as in forests, and as such has no effect on the human body.

·

A slight noise may be heard during operation. This does not indicate a malfunction.



Y210037C01
2.188,1.448 2.365,1.448 2.365,1.448 2.75,2.292 true 4.583,1.885 4.698,1.885 4.698,1.885 4.792,1.573 true 5.51,1.896 5.625,1.896 5.625,1.896 5.729,1.521 true 4.76,1.333 4.875,1.01 4.875,1.01 5,1.01 true 5.948,1 6.021,0.802 6.021,0.802 6.146,0.802 true 2.031,1.365 2.344,1.521 0.313,0.156 10 false *1 4.292,0.573 4.604,0.729 0.313,0.156 10 false *a 4.417,1.781 4.729,1.938 0.313,0.156 10 false *b 5.021,0.917 5.333,1.073 0.313,0.156 10 false *c 5.333,1.802 5.646,1.958 0.313,0.156 10 false *b 6.167,0.698 6.479,0.854 0.313,0.156 10 false *c
*1 No. 2 Ion Generator Sub-assembly - -
*a Common Negative Ion "nanoe" Ions *b H2O
*c Electron - -


HINT:

"nanoe" is a trademark of Panasonic Corporation.





DIAGNOSIS


a.

The air conditioner ECU has a self-diagnosis function. It stores any operation failures in the air conditioner system memory in the form of DTC (Diagnostic Trouble Code). For details, see Repair Manual.