| Condition | Specified Condition |
|---|---|
| Standard valve opening temperature | 80 to 84°C (176 to 183°F) |
| Standard valve lift | 10 mm (0.39 in.) or more at 95°C (203°F) |
| Item | Indication Mark | Motor Type | Condition | Specified Condition |
|---|---|---|---|---|
| No. 1 cooling fan motor | 2859 | 160 W | at 20°C (68°F) | 11.7 to 14.7 A |
| 2860 | 200 W | at 20°C (68°F) | 14.7 to 18.7 A | |
| No. 2 cooling fan motor | 2859 | 120 W | at 20°C (68°F) | 8.4 to 10.4 A |
| 2860 | 200 W | at 20°C (68°F) | 14.7 to 18.7 A |
| Item | Tester Connection | Specified Condition |
|---|---|---|
| No. 1 fan relay | 3 - 5 | 10 Ωor higher |
| 3 - 5 | Below 1 Ω
(when battery voltage is applied to terminals 1 and 2) |
|
| No. 2 fan relay | 3 - 4 | Below 1 Ω |
| 3 - 5 | 10 Ωor higher | |
| 3 - 4 | 10 Ωor higher
(when battery voltage is applied to terminals 1 and 2) |
|
| 3 - 5 | Below 1 Ω
(when battery voltage is applied to terminals 1 and 2) |
|
| No. 3 fan relay | 3 - 5 | 10 Ωor higher |
| 3 - 5 | Below 1 Ω
(when battery voltage is applied to terminals 1 and 2) |
| Item | Condition | Specified Condition |
|---|---|---|
| Radiator reservoir cap | For brand-new cap | 93.3 to 122.7 kPa (0.95 to 1.25 kgf/cm2, 13.5 to 17.8 psi) |
| After using cap | 78.5 kPa (0.8 kgf/cm2, 11.4 psi) |