RM24M0E
_V1
General
_059539
SPECIFICATIONS
_0291759
2GR-FE EMISSION CONTROL
F
SPECIFICATIONS 2GR-FE EMISSION CONTROL SERVICE DATA
Purge VSV
| Tester Connection
|
Specified Condition
|
| 1 - 2
|
23 to 26Ω at 20°C ( 68°F )
|
| 1 - Body ground
|
10 MΩ or higher
|
| 2 - Body ground
|
10 MΩ or higher
|
Air fuel ratio sensor ( for Bank 1 Sensor 1 )
| Tester Connection
|
Specified Condition
|
| 1 ( HA1A ) - 2 ( +B )
|
for Type A:
1.8 to 3.4 Ω at 20°C ( 68°F )
|
for Type B:
1.6 to 3.2 Ω at 20°C ( 68°F )
|
| 1 ( HA1A ) - 4 ( A1A- )
|
10 kΩ or higher
|
Air fuel ratio sensor ( for Bank 2 Sensor 1 )
| Tester Connection
|
Specified Condition
|
| 1 ( HA2A ) - 2 ( +B )
|
for Type A:
1.8 to 3.4 Ω at 20°C ( 68°F )
|
for Type B:
1.6 to 3.2 Ω at 20°C ( 68°F )
|
| 1 ( HA2A ) - 4 ( A2A- )
|
10 kΩ or higher
|
Oxygen sensor ( for Bank 1 Sensor 2 )
| Tester Connection
|
Specified Condition
|
| 2 ( HT1B ) - 1 ( +B )
|
11 to 16 Ω at 20°C ( 68°F )
|
| 2 ( HT1B ) - 3 ( E2 )
|
10 kΩ or higher
|
Oxygen sensor ( for Bank 2 Sensor 2 )
| Tester Connection
|
Specified Condition
|
| 2 ( +B ) - 1 ( HT2B )
|
11 to 16 Ω at 20°C ( 68°F )
|
| 1 ( HT2B ) - 4 ( E2 )
|
10 kΩ or higher
|