Home › General › SPECIFICATIONS › 2GR-FE COOLING
RM24M0E _V1 General _059539 SPECIFICATIONS _0291762 2GR-FE COOLING F

SPECIFICATIONS  2GR-FE COOLING  SERVICE DATA  


THERMOSTAT:
Condition Specified Condition
Standard valve opening temperature 80 to 84°C (176 to 183°F)
Standard valve lift 10 mm (0.39 in.) or more at 95°C (203°F)


COOLING FAN MOTOR:
Item Condition Specified Condition
No. 1 cooling fan motor 20°C (68°F) 18 to 22 A
No. 2 cooling fan motor 20°C (68°F) 18 to 22 A


COOLING FAN ECU:
Item Condition Specified Condition
No. 1 cooling fan ECU Ignition switch on (IG) 9 to 14 V
No. 2 cooling fan ECU Ignition switch on (IG) 9 to 14 V


COOLING FAN RELAY:
Item Tester Connection Specified Condition
No. 1 fan relay 3 - 5 10 kΩor higher
3 - 5 Below 1 Ω
(when battery voltage is applied to terminals 1 and 2)
No. 2 fan relay 3 - 5 10 kΩor higher
3 - 5 Below 1 Ω
(when battery voltage is applied to terminals 1 and 2)


RADIATOR:
Item Condition Specified Condition
Radiator reservoir cap For brand-new cap 93.3 to 122.7 kPa (0.95 to 1.25 kgf/cm2, 13.5 to 17.8 psi)
For used cap 78.5 kPa (0.8 kgf/cm2, 11.4 psi)