RM24M0E
_V1
General
_059539
SPECIFICATIONS
_0291762
2GR-FE COOLING
F
SPECIFICATIONS 2GR-FE COOLING SERVICE DATA
- THERMOSTAT:
| Condition
|
Specified Condition
|
| Standard valve opening temperature
|
80 to 84°C (176 to 183°F)
|
| Standard valve lift
|
10 mm (0.39 in.) or more at 95°C (203°F)
|
- COOLING FAN MOTOR:
| Item
|
Condition
|
Specified Condition
|
| No. 1 cooling fan motor
|
20°C (68°F)
|
18 to 22 A
|
| No. 2 cooling fan motor
|
20°C (68°F)
|
18 to 22 A
|
- COOLING FAN ECU:
| Item
|
Condition
|
Specified Condition
|
| No. 1 cooling fan ECU
|
Ignition switch on (IG)
|
9 to 14 V
|
| No. 2 cooling fan ECU
|
Ignition switch on (IG)
|
9 to 14 V
|
- COOLING FAN RELAY:
| Item
|
Tester Connection
|
Specified Condition
|
| No. 1 fan relay
|
3 - 5
|
10 kΩor higher
|
| 3 - 5
|
Below 1 Ω
(when battery voltage is applied to terminals 1 and 2)
|
| No. 2 fan relay
|
3 - 5
|
10 kΩor higher
|
| 3 - 5
|
Below 1 Ω
(when battery voltage is applied to terminals 1 and 2)
|
- RADIATOR:
| Item
|
Condition
|
Specified Condition
|
| Radiator reservoir cap
|
For brand-new cap
|
93.3 to 122.7 kPa (0.95 to 1.25 kgf/cm2, 13.5 to 17.8 psi)
|
| For used cap
|
78.5 kPa (0.8 kgf/cm2, 11.4 psi)
|