The Intake Air Temperature (IAT) sensor, mounted on the Mass Air Flow (MAF) meter, monitors the IAT. The IAT sensor has a built-in thermistor with a resistance that varies according to the temperature of the intake air. When the IAT is low, the resistance of the thermistor increases. When the temperature is high, the resistance drops. These variations in resistance are transmitted to the ECM as voltage changes (see Fig. 1).
The IAT sensor is powered by a 5 V supply from the THA terminal of the ECM, via resistor R.
Resistor R and the IAT sensor are connected in series. When the resistance value of the IAT sensor changes, the voltage at terminal THA varies accordingly. Based on this signal, the ECM increases the fuel injection volume when the engine is cold to improve driveability.
When any of DTCs P0110, P0112 and/or P0113 are set, the ECM enters fail-safe mode. During fail-safe mode, the IAT is estimated to be 20°C (68°F) by the ECM. Fail-safe mode continues until a pass condition is detected.
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| P0110 | Open or short in IAT sensor circuit for 0.5 seconds
(1 trip detection logic) |
·
Open or short in IAT sensor circuit ·
IAT sensor (built into MAF meter) ·
ECM |
| P0112 | Short in IAT sensor circuit for 0.5 seconds (1 trip detection logic) | ·
Short in IAT sensor circuit ·
IAT sensor (built into MAF meter) ·
ECM |
| P0113 | Open in IAT sensor circuit for 0.5 seconds (1 trip detection logic) | ·
Open in IAT sensor circuit ·
IAT sensor (built into MAF meter) ·
ECM |
When any of these DTCs are set, check the IAT by selecting the following menu items on the intelligent tester: Powertrain / Engine and ECT / Data List / Intake Air.
| Temperature Displayed | Malfunction |
|---|---|
| -40°C (-40°F) | Open circuit |
| 140°C (284°F) or more | Short circuit |
Read freeze frame data using the intelligent tester. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air-fuel ratio was lean or rich, and other data from the time the malfunction occurred.
Connect the intelligent tester to the DLC3.
Turn the engine switch on (IG) and turn the tester ON.
Enter the following menus: Powertrain / Engine and ECT / Data List / Intake Air.
Read the value displayed on the tester.
Same as actual Intake Air Temperature (IAT).
| Temperature Displayed | Proceed to |
|---|---|
| -40°C (-40°F) | A |
| 140°C (284°F) or more | B |
| Same as actual IAT | C |
If there is an open circuit, the intelligent tester indicates -40°C (-40°F).
If there is a short circuit, the intelligent tester indicates 140°C (284°F) or more.
A
B
C
Disconnect the Mass Air Flow (MAF) meter connector.
Connect terminals THA and E2 of the MAF meter wire harness side connector.
Connect the intelligent tester to the DLC3.
Turn the engine switch on (IG) and turn the tester ON.
Enter the following menus: Powertrain / Engine and ECT / Data List / Intake Air.
Read the value displayed on the tester.
140°C (284°F) or more
NG
OK
Disconnect the MAF meter connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| D3-1 (THA) - D2-65 (THA) | Always | Below 1 Ω |
| D3-2 (E2) - D2-88 (ETHA) |
OK
NG
Disconnect the MAF meter connector.
Connect an intelligent tester to the DLC3.
Turn the engine switch on (IG) and turn the tester ON.
Enter the following menus: Powertrain / Engine and ECT / Data List / Intake Air.
Read the value displayed on the tester.
-40°C (-40°F)
NG
OK
Disconnect the MAF meter connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| D3-1 (THA) or D2-65 (THA) - Body ground | Always | 10 kΩ or higher |
OK
NG