23221
1.INSPECT FUEL PUMP ASSEMBLY
Inspect fuel pump resistance.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | 20°C (68°F) | 0.2 to 3.0 Ω |
If the result is not as specified, replace the fuel pump.
Inspect fuel pump operation.
Connect a battery positive (+) lead to terminal 2 of the connector, and a negative (-) lead to terminal 1. Check that the fuel pump operates.
These tests must be performed within 10 seconds to prevent the coil from burning out.
Keep the fuel pump as far away from the battery as possible.
Always switch the voltage on and off on the battery side, not the fuel pump side.
If the pump does not operate, replace the fuel pump.