89467B
1.INSPECT AIR FUEL RATIO SENSOR (for Bank 1 Sensor 1)
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 (HA1A) - 2 (+B) | 20°C (68°F) | for Type A:
1.8 to 3.4 Ω for Type B: 1.6 to 3.2 Ω |
| 1 (HA1A) - 4 (A1A-) | - | 10 kΩ or higher |
If the result is not as specified, replace the air fuel ratio sensor.
89467C
2.INSPECT AIR FUEL RATIO SENSOR NO. 2 (for Bank 2 Sensor 1)
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 (HA2A) - 2 (+B) | 20°C (68°F) | for Type A:
1.8 to 3.4 Ω for Type B: 1.6 to 3.2 Ω |
| 1 (HA2A) - 4 (A2A-) | - | 10 kΩ or higher |
If the result is not as specified, replace the air fuel ratio sensor No. 2.