Home › Engine / Hybrid System › 2GR-FE EMISSION CONTROL › HEATED OXYGEN SENSOR
RM24M0E _51 Engine / Hybrid System _059544 2GR-FE EMISSION CONTROL _0291812 HEATED OXYGEN SENSOR G

2GR-FE EMISSION CONTROL  HEATED OXYGEN SENSOR  INSPECTION  


PROCEDURE

Hide 89465 1.INSPECT HEATED OXYGEN SENSOR (for Bank 1 Sensor 2)

a.
A161881E03
0.713,2.281 1.098,2.437 0.385,0.156 10 HT1B 0.713,2.919 1.109,3.064 0.395,0.145 10 OX1B 2.325,2.281 2.540,2.437 0.215,0.156 10 +B 2.325,2.919 2.543,3.078 0.218,0.159 10 E2 1.472,2.482 1.18,2.364 false 1.966,2.48 2.295,2.37 false 1.467,2.841 1.189,2.995 false 1.974,2.841 2.299,2.997 false

Measure the resistance of the sensor.

Standard resistance:
Tester Connection Specified Condition
2 (HT1B) - 1 (+B) 11 to 16 Ω at 20°C (68°F)
2 (HT1B) - 3 (E2) 10 kΩ or higher


If the resistance is not as specified, replace the sensor.


Hide 89465A 2.INSPECT HEATED OXYGEN SENSOR (for Bank 2 Sensor 2)

a.
A161881E06
1.469,2.479 1.177,2.365 false 1.938,2.51 2.292,2.375 false 1.469,2.844 1.188,3 false 1.948,2.813 2.302,3 false 0.938,2.26 1.448,2.771 0.51,0.51 10 false +B 0.969,2.938 1.365,3.083 0.396,0.146 10 false E2 2.333,2.281 2.833,2.469 0.5,0.188 10 false HT1B 2.344,2.948 2.865,3.135 0.521,0.188 10 false OX1B

Measure the resistance of the sensor.

Standard resistance:
Tester Connection Specified Condition
1 (HT2B) - 2 (+B) 11 to 16 Ω at 20°C (68°F)
1 (HT2B) - 4 (E2) 10 kΩ or higher


If the resistance is not as specified, replace the sensor.