89467B
1.INSPECT AIR FUEL RATIO SENSOR (for Bank 1 Sensor 1)
Measure the resistance of the sensor.
| Tester Connection | Specified Condition |
|---|---|
| 1 (HA1A) - 2 (+B) | 1.8 to 3.4 Ω at 20°C (68°F) |
| 1 (HA1A) - 4 (A1A-) | 10 kΩ or higher |
If the resistance is not as specified, replace the sensor.