89465
1.INSPECT HEATED OXYGEN SENSOR (for Bank 1 Sensor 2)
Measure the resistance of the sensor.
| Tester Connection | Specified Condition |
|---|---|
| 1 (HT1B) - 2 (+B) | 11 to 16 Ω at 20°C (68°F) |
| 1 (HT1B) - 4 (E2) | 10 kΩ or higher |
If the resistance is not as specified, replace the sensor.