Home › Engine / Hybrid System › 2AZ-FE EMISSION CONTROL › PCV VALVE
RM24M0E _51 Engine / Hybrid System _059545 2AZ-FE EMISSION CONTROL _0291821 PCV VALVE A

2AZ-FE EMISSION CONTROL  PCV VALVE  INSTALLATION  


PROCEDURE

Hide 12204 1.INSTALL VENTILATION VALVE SUB-ASSEMBLY

a.
A092670E35
2.281,0.646 2.24,0.26 2.24,0.26 1.979,0.26 false 1.313,0.177 1.917,0.354 0.604,0.177 10 false Adhesive

Apply adhesive to 2 or 3 threads of the ventilation valve.

Adhesive:

Toyota Genuine Adhesive 1324, Three Bond 1324 or equivalent



b.
A098067E05
0.896,0.177 0.677,0.177 false 0.677,0.177 1.229,1.042 false 0.917,0.094 2.792,0.25 1.875,0.156 10 false 22 mm Deep Socket Wrench

Using a 22 mm deep socket wrench, install the ventilation valve.

Torque:
19 N*m (194 kgf*cm, 14 ft.*lbf)


c.

Connect the ventilation hose.


Hide 2.CHECK FOR ENGINE OIL LEAKS