1.CHECK BRAKE FLUID LEVEL WARNING SWITCH
Remove the reservoir filler cap and strainer.
Disconnect the brake fluid level warning switch connector.
Measure the resistance of the switch.
There is a float inside the reservoir. Its position can be changed by increasing or decreasing the brake fluid level.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | Float up (Switch OFF) | 10 kΩ or higher |
| 1 - 2 | Float down (Switch ON) | Below 1 Ω |
If the value is not as specified, replace the brake master cylinder reservoir sub-assembly.
Add brake fluid to the MAX level.