The SRS is equipped with a voltage-increase circuit (DC-DC converter) in the center airbag sensor in case the source voltage drops.
When the source voltage drops, the voltage-increase circuit (DC-DC converter) functions to increase the voltage of the SRS to a normal working level.
A malfunction in this circuit is displayed differently from other codes, in the fact that no DTCs are recorded. With a normal system code present, the source voltage drop is indicated when the SRS warning light comes on.
A malfunction in this circuit is not recorded in the center airbag sensor.
The SRS warning light automatically goes off when the source voltage returns to normal.
Turn the ignition switch off.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Disconnect the G19 sensor connector.
Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the ignition switch on (IG).
Measure the voltage of the wire harness side connector.
| Tester Connection | Specified Condition |
|---|---|
| G19-21 (IG2) - Body ground | 11 to 14 V |
OK
NG
Measure the resistance of the wire harness side connector.
| Tester Connection | Specified Condition |
|---|---|
| G19-25 (E1) - Body ground | Below 1 Ω |
| G19-26 (E2) - Body ground |
OK
NG
Turn the ignition switch off.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Connect the G19 sensor connector.
Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.
Turn the ignition switch on (IG), and wait for at least 6 seconds.
Operate all components of the electrical system (defogger, wiper, headlight, heater, blower, etc.) and check that SRS warning light does not come on.
SRS warning light does not come on.
OK
NG