The SRS warning light is located on the combination meter.
When the SRS is normal, the SRS warning light comes on for approximately 6 seconds after the ignition switch is turned from off to on (IG), and then goes off automatically.
If there is a malfunction in the SRS, the SRS warning light comes on to inform the driver of a problem.
When terminals TC and CG of the DLC3 are connected, the DTC is displayed blinking the SRS warning light.
The SRS is equipped with a voltage-increase circuit (DC-DC converter) in the center airbag sensor in case the source voltage drops.
When the battery voltage drops, the voltage-increase circuit (DC-DC converter) functions to increase the voltage of the SRS to normal voltage.
A malfunction in this circuit is not recorded in the center airbag sensor. The SRS warning light automatically goes off when the source voltage returns to normal.
The signal to illuminate the SRS warning light is transmitted from the center airbag sensor to the combination meter through the multiplex communication system.
Measure the voltage of the battery.
11 to 14 V
OK
NG
Turn the ignition switch off.
Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
Check that the connectors are properly connected to the center airbag sensor and the combination meter.
Connectors are properly connected.
OK
NG
Turn the ignition switch off.
Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
Disconnect the G28 meter connector.
Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.
Turn the ignition switch on (IG).
Measure the voltage of the wire harness side connector.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G28-21 (IG2) - Body ground | Ignition switch on (IG) | 10 to 14 V |
| G28-22 (B) - Body ground | Always |
Turn the ignition switch off.
Measure the resistance of the wire harness side connector.
| Tester Connection | Specified Condition |
|---|---|
| G28-33 (EP) - Body ground | Below 1 Ω |
OK
NG
Turn the ignition switch off.
Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
Connect the G28 meter connector.
Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.
Turn the ignition switch on (IG).
Check the SRS warning light condition.
After the primary check period, the SRS warning light goes off for approximately 10 seconds, and then turns on and remains on.
The primary check period continues for approximately 6 seconds after the ignition switch is turned on (IG).
OK
NG