84975
1.INSPECT TRIP SWITCH
Measure the resistance of the switch
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 5 (+) - 6 (E) | ODO TRIP SWITCH OFF | 10 kΩ or higher |
| 5 (+) - 6 (E) | ODO TRIP SWITCH ON | Below 1Ω |
| 4 (TC) - 6 (E) | RHEOSTAT SWITCH OFF | 10 kΩ or higher |
| 4 (TC) - 6 (E) | RHEOSTAT SWITCH ON | Below 1Ω |
| 10 (H) - 6 (E) | H SWITCH OFF | 10 kΩ or higher |
| 10 (H) - 6 (E) | H SWITCH ON | Below 1Ω |
| 2 (RSET) - 6 (E) | RSET SWITCH OFF | 10 kΩ or higher |
| 2 (RSET) - 6 (E) | RSET SWITCH ON | Below 1Ω |
| 9 (ILL) - 6 (E) | Always | Below 1Ω |
| 8 (M) - 6 (E) | M SWITCH OFF | 10 kΩ or higher |
| 8 (M) - 6 (E) | M SWITCH ON | Below 1Ω |
| 7 (TB) - 6 (E) | OFF | 10 kΩ or higher |
| 7 (TB) - 6 (E) | ON | Below 23.4 Ω |
Measure the resistance of the switch.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 1 (+) - 10 (E) | ODO TRIP SWITCH OFF | 10 kΩ or higher |
| 1 (+) - 10 (E) | ODO TRIP SWITCH ON | Below 1Ω |
| 2 (TC) - 10 (E) | RHEOSTAT SWITCH OFF | 10 kΩ or higher |
| 2 (TC) - 10 (E) | RHEOSTAT SWITCH ON | Below 1Ω |
| 4 (H) - 10 (E) | H SWITCH OFF | 10 kΩ or higher |
| 4 (H) - 10 (E) | H SWITCH ON | Below 1Ω |
| 6 (RSET) - 10 (E) | 00 SWITCH OFF | 10 kΩ or higher |
| 6 (RSET) - 10 (E) | 00 SWITCH ON | Below 1Ω |
| 7 (ILL) - 10 (E) | Always | Below 1Ω |
| 8 (M) - 10 (E) | M SWITCH OFF | 10 kΩ or higher |
| 8 (M) - 10 (E) | M SWITCH ON | Below 1Ω |
| 9 (TB) - 10 (E) | OFF | 10 kΩ or higher |
| 9 (TB) - 10 (E) | ON | Below 23.4 Ω |
Inspect the switch illumination.
Connect the battery positive (+) lead to terminal 7 (ILL+) and the negative (-) lead to terminal 10 (E). Then check that the light comes on.
LED illuminates.
If the result is not as specified, replace the transponder key amplifier.