Home › Vehicle Interior › WIPER / WASHER › FRONT WIPER MOTOR
RM24M0E _58 Vehicle Interior _059565 WIPER / WASHER _0291976 FRONT WIPER MOTOR G

WIPER / WASHER  FRONT WIPER MOTOR  INSPECTION  


PROCEDURE

Hide 85110 1.INSPECT WINDSHIELD WIPER MOTOR ASSEMBLY

E034081E20
2.045,0.844 2.286,0.337 false 1.736,0.844 1.977,0.337 false 0.877,1.66 1.341,0.955 false 1.289,1.84 1.53,1.333 false 1.65,1.858 1.891,1.351 false 0.797,1.672 1.016,1.814 0.219,0.142 10 +S 1.951,0.156 2.093,0.298 0.142,0.142 10 B 1.229,1.849 1.371,1.991 0.142,0.142 10 E 1.547,1.858 1.751,2.000 0.205,0.142 10 +2 2.217,0.147 2.422,0.289 0.205,0.142 10 +1

a.

Check the LO operation.

i.

Connect the battery's positive (+) lead to terminal 1 (+1) and the negative (-) lead to terminal 5 (E), and check that the motor operates at low speed (LO).

OK:

Motor operates at low speed (LO).




b.

Check the HI operation.

i.

Connect the battery's positive (+) lead to terminal 4 (+2) and the negative (-) lead to terminal 5 (E), and check that the motor operates at high speed (HI).

OK:

Motor operates at high speed (HI).




c.

Check the automatic stop operation.

i.

Connect the battery's positive (+) lead to terminal 1 (+1) and the negative (-) lead to terminal 5 (E). With the motor rotating at low speed (LO), disconnect terminal 1 (+1) to stop the wiper motor operation at any position other than the automatic stop position.


ii.

Using SST, connect terminals 3 (+S) and 1 (+1). Then connect the battery's positive (+) lead to terminal 2 (B) and the negative (-) lead to terminal 5 (E) to restart the motor operation at low speed (LO).

SST
09843-18040  


iii.
B131458E01
0.064,0.943 0.327,1.094 0.262,0.151 10 22° 0.382,0.861 0.672,1.035 0.290,0.174 10 +5° 0.333,1.037 0.641,1.184 0.308,0.147 10 -10° 0.831,1.752 2.343,1.908 1.512,0.156 10 Automatic Stop Position 0.476,1.66 0.639,1.845 0.639,1.845 0.799,1.845 false 0.052,0.004 0.652,0.180 0.600,0.176 10 for LHD:

B131459E04
2.844,1.656 2.708,1.896 2.708,1.896 2.521,1.896 false 2.76,0.885 2.99,1.073 0.229,0.188 10 false 22° 3.01,0.781 3.292,0.958 0.281,0.177 10 false +5° 2.979,0.99 3.302,1.135 0.323,0.146 10 false -10° 0.979,1.823 2.49,2.01 1.51,0.188 10 false Automatic Stop Position 0.042,0 0.656,0.156 0.615,0.156 10 false for RHD:

Check that the motor stops automatically at the automatic stop position.

OK:

Refer to illustration.


If the result is not as specified, replace the motor assembly.