CHECK FOLD SEAT CONTROL ECU LH
Disconnect the Z2 and Z3 ECU connectors.
Measure the voltage and resistance of the wire harness side connectors.
| Symbols (Terminal No). | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| IG (Z3-3) - E (Z2-8) | P - W-B | Power source (IG) | Ignition switch on (IG) | 10 to 14 V |
| IG (Z3-3) - E (Z2-8) | P - W-B | Power source (IG) | Ignition switch off | Below 1 V |
| +B (Z2-4) - E (Z2-8) | Y - W-B | Power source (Battery) | Always | 10 to 14 V |
| E (Z2-8) - Body ground | W-B - Body ground | Ground | Always | Below 1 Ω |
If the result is not as specified, there may be a malfunction on the wire harness side.
Reconnect the Z2 and Z3 ECU connectors.
Measure the voltage of the wire harness side connectors.
| Symbols (Terminal No.) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| BCTY (Z3-5) - E (Z2-8) | P - W-B | Back door courtesy switch signal | Back door courtesy switch OFF | 10 to 14 V |
| BCTY (Z3-5) - E (Z2-8) | P - W-B | Back door courtesy switch signal | Back door courtesy switch ON | Below 1 V |
| RCLF (Z3-12) - E (Z2-8) | L - W-B | Reclining seat switch signal | Always | 10 to 14 V |
| RCLF (Z3-12) - E (Z2-8) | L - W-B | Reclining seat switch signal | Power rear seat switch Forward | Below 1 V |
| RCLR (Z3-13) - E (Z2-8) | SB - W-B | Reclining seat switch signal | Always | 10 to 14 V |
| RCLR (Z3-13) - E (Z2-8) | SB - W-B | Reclining seat switch signal | Power rear seat switch Backward | Below 1 V |
| TBL (Z3-14) - E (Z2-8) | LG - W-B | Fold seat switch signal
(Folding) |
Folding switch OFF | 10 to 14 V |
| TBL (Z3-14) - E (Z2-8) | LG - W-B | Fold seat switch signal
(Folding) |
Folding switch ON | Below 1 V |
| RTRN (Z3-15) - E (Z2-8) | BR - W-B | Fold seat switch signal
(Return) |
Stowing / Return switch OFF | 10 to 14 V |
| RTRN (Z3-15) - E (Z2-8) | BR - W-B | Fold seat switch signal
(Return) |
Stowing / Return switch ON | Below 1 V |
| FOLD (Z3-16) - E (Z2-8) | Y - W-B | Fold seat switch signal
(Stowing) |
Stowing / Return switch OFF | 10 to 14 V |
| FOLD (Z3-16) - E (Z2-8) | Y - W-B | Fold seat switch signal
(Stowing) |
Stowing / Return switch ON | Below 1 V |
| SRCL (Z3-22) - SG2 (Z3-36) | O - V | Seatback position sensor signal | Motor is operating | Below 1 V - 10 to 14 V
Pulse generation |
| SFLD (Z3-23) - E (Z2-8) | B - W-B | Seat cushion position sensor signal | Motor is operating | Below 1 V - 10 to 14 V
Pulse generation |
| SV1 (Z3-24) - E (Z2-8) | W - W-B | Power supply for seat cushion position sensor | Back door OPEN | 9 to 14 V |
| SV2 (Z3-25) - E (Z2-8) | G - W-B | Power supply for seatback position sensor | Back door OPEN | 9 to 14 V |
| SG1 (Z3-30) - Body ground | R - Body ground | Ground for seat cushion position sensor | Always | Below 1 V |
| P (Z3-32) - E (Z2-8) | SB - W-B | Park / Neutral position sensor signal | Ignition switch on (IG)
Park / Neutral position switch P position |
10 to 14 V |
| P (Z3-32) - E (Z2-8) | SB - W-B | Park / Neutral position sensor signal | Ignition switch on (IG)
Park / Neutral position switch except P position |
Below 1 V |
| IND2 (Z3-34) - E (Z2-8) | GR - W-B | 3RD SEAT indicator signal | Ignition switch on (IG) | 10 to 14 V |
| IND2 (Z3-34) - E (Z2-8) | GR - W-B | 3RD SEAT indicator signal | Ignition switch on (IG)
·
When the reclining motor or fold seat control ECU is not initialized. ·
When any seat legs are released. ·
When the seatback is outside the reclining operation range. |
1 to 3 V |
| IND1 (Z3-35) - E (Z2-8) | L - W-B | Fold seat switch indicator signal | Fold seat switch ON
Back door OPEN ·
When the system detects that an object is caught. ·
When the seat operation conditions are not met. |
Below 1.5 V |
| IND1 (Z3-35) - E (Z2-8) | L - W-B | Fold seat switch indicator signal | Fold seat switch OFF
Back door OPEN ·
When the system detects that an object is caught. ·
When the seat operation conditions are not met. |
9 to 13 V |
| SG2 (Z3-36) - Body ground | V - Body ground | Ground for seatback position sensor | Always | Below 1 V |
| LCKR (Z3-37) - E (Z2-8) | V - W-B | Fold lock switch signal | Fold lock switch LOCK
Back door OPEN |
10 to 14 V |
| LCKR (Z3-37) - E (Z2-8) | V - W-B | Fold lock switch signal | Fold lock switch UNLOCK | Below 1 V |
| LCKF (Z3-38) - E (Z2-8) | B - W-B | Lock switch signal | Lock switch LOCK
Back door OPEN |
10 to 14 V |
| LCKF (Z3-38) - E (Z2-8) | B - W-B | Lock switch signal | Lock switch UNLOCK | Below 1 V |
| FLD+ (Z2-1) - E (Z2-8) | G - W-B | Folding motor operation signal | Stowing / Return switch Stowing
Back door OPEN Ignition switch off Park / Neutral position switch P position |
10 to 14 V |
| RCL+ (Z2-2) - E (Z2-8) | B - W-B | Reclining motor operation signal | Power rear seat switch Forward
Back door OPEN Lock switch UNLOCK |
10 to 14 V |
| RACT (Z2-3) - E (Z2-8) | P - W-B | Release actuator operation signal | Stowing / Return switch Return
Back door OPEN Ignition switch off Park / Neutral position switch P position |
10 to 14 V |
| FLD- (Z2-5) - E (Z2-8) | R - W-B | Folding motor operation signal | Stowing / Return switch Return
Back door OPEN Ignition switch off Park / Neutral position switch P position |
10 to 14 V |
| RCL- (Z2-6) - E (Z2-8) | L - W-B | Reclining motor operation signal | Power rear seat switch Backward
Back door OPEN Lock switch UNLOCK |
10 to 14 V |
If the result is not as specified, the fold seat control ECU may have a malfunction.
CHECK FOLD SEAT CONTROL ECU RH
Disconnect the Y2 and Y3 ECU connectors.
Measure the voltage and resistance of the wire harness side connectors.
| Symbols (Terminal No.) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| IG (Y3-3) - E (Y2-8) | P - W-B | Power source (IG) | Ignition switch on (IG) | 10 to 14 V |
| IG (Y2-3) - E (Y2-8) | P - W-B | Power source (IG) | Ignition switch off | Below 1 V |
| +B (Y3-4) - E (Y2-8) | Y - W-B | Power source (Battery) | Always | 10 to 14 V |
| E (Y2-8) - Body ground | W-B - Body ground | Ground | Always | Below 1 Ω |
If the result is not as specified, there may be a malfunction on the wire harness side.
Reconnect the Y2 and Y3 ECU connectors.
Measure the voltage of the wire harness side connectors.
| Symbols (Terminal No.) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| BCTY (Y3-5) - E (Y2-8) | P - W-B | Back door courtesy switch signal | Back door courtesy switch OFF | 10 to 14 V |
| BCTY (Y3-5) - E (Y2-8) | P - W-B | Back door courtesy switch signal | Back door courtesy switch ON | Below 1 V |
| RCLF (Y3-12) - E (Y2-8) | L - W-B | Reclining seat switch signal | Always | 10 to 14 V |
| RCLF (Y3-12) - E (Y2-8) | L - W-B | Reclining seat switch signal | Power rear seat switch Forward | Below 1 V |
| RCLR (Y3-13) - E (Y2-8) | SB - W-B | Reclining seat switch signal | Always | 10 to 14 V |
| RCLR (Y3-13) - E (Y2-8) | SB - W-B | Reclining seat switch signal | Power rear seat switch Backward | Below 1 V |
| TBL (Y3-14) - E (Y2-8) | LG - W-B | Fold seat switch signal
(Folding) |
Folding switch OFF | 10 to 14 V |
| TBL (Y3-14) - E (Y2-8) | LG - W-B | Fold seat switch signal
(Folding) |
Folding switch ON | Below 1 V |
| RTRN (Y3-15) - E (Y2-8) | BR - W-B | Fold seat switch signal
(Return) |
Stowing / Return switch OFF | 10 to 14 V |
| RTRN (Y3-15) - E (Y2-8) | BR - W-B | Fold seat switch signal
(Return) |
Stowing / Return switch ON | Below 1 V |
| FOLD (Y3-16) - E (Y2-8) | Y - W-B | Fold seat switch signal
(Stowing) |
Stowing / Return switch OFF | 10 to 14 V |
| FOLD (Y3-16) - E (Y2-8) | Y - W-B | Fold seat switch signal
(Stowing) |
Stowing / Return switch ON | Below 1 V |
| SRCL (Y3-22) - SG2 (Y3-36) | O - V | Seatback position sensor signal | Motor is operating | Below 1 V - 10 to 14 V
Pulse generation |
| SFLD (Y3-23) - E (Y2-8) | B - W-B | Seat cushion position sensor signal | Motor is operating | Below 1 V - 10 to 14 V
Pulse generation |
| SV1 (Y3-24) - E (Y2-8) | W - W-B | Power supply for seat cushion position sensor | Back door OPEN | 9 to 14 V |
| SV2 (Y3-25) - E (Y2-8) | G - W-B | Power supply for seatback position sensor | Back door OPEN | 9 to 14 V |
| SG1 (Y3-30) - Body ground | R - Body ground | Ground for folding position sensor | Always | Below 1 V |
| P (Y3-32) - E (Y2-8) | SB - W-B | Park / Neutral position sensor signal | Ignition switch on (IG)
Park / Neutral position switch P position |
10 to 14 V |
| P (Y3-32) - E (Y2-8) | SB - W-B | Park / Neutral position sensor signal | Ignition switch on (IG)
Park / Neutral position switch Except P position |
Below 1 V |
| IND2 (Y3-34) - E (Y2-8) | GR - W-B | 3RD SEAT indicator signal | Ignition switch on (IG) | 10 to 14 V |
| IND2 (Y3-34) - E (Y2-8) | GR - W-B | 3RD SEAT indicator signal | Ignition switch on (IG)
·
When the reclining motor or fold seat control ECU is not initialized. ·
When any seat legs are released. ·
When the seatback is outside the reclining operation range. |
1 to 3 V |
| IND1 (Y3-35) - E (Y2-8) | L - W-B | Fold seat switch indicator signal | Fold seat switch ON
Back door OPEN ·
When the system detects that an object is caught. ·
When the seat operation conditions are not met. |
Below 1.5 V |
| IND1 (Y3-35) - E (Y2-8) | L - W-B | Fold seat switch indicator signal | Fold seat switch OFF
Back door OPEN ·
When the system detects that an object is caught. ·
When the seat operation conditions are not met. |
9 to 13 V |
| SG2 (Y3-36) - Body ground | V - Body ground | Ground for seatback position sensor | Always | Below 1 V |
| LCKR (Y3-37) - E (Y2-8) | V - W-B | Fold lock switch signal | Fold lock switch LOCK
Back door OPEN |
10 to 14 V |
| LCKR (Y3-37) - E (Y2-8) | V - W-B | Fold lock switch signal | Fold lock switch UNLOCK
Back door OPEN |
Below 1 V |
| LCKF (Y3-38) - E (Y2-8) | B - W-B | Lock switch signal | Lock switch LOCK | 10 to 14 V |
| LCKF (Y3-38) - E (Y2-8) | B - W-B | Lock switch signal | Lock switch UNLOCK | Below 1 V |
| FLD+ (Y2-1) - E (Y2-8) | G - W-B | Folding motor operation signal | Stowing / Return switch Stowing
Back door OPEN Ignition switch off Park / Neutral position switch P position |
10 to 14 V |
| RCL+ (Y2-2) - E (Y2-8) | B - W-B | Reclining motor operation signal | Power rear seat switch Forward
Back door OPEN Lock switch UNLOCK |
10 to 14 V |
| RACT (Y2-3) - E (Y2-8) | P - W-B | Release actuator operation signal | Stowing / Return switch Return
Back door OPEN Ignition switch off Park / Neutral position switch P position |
10 to 14 V |
| FLD- (Y2-5) - E (Y2-8) | R - W-B | Folding motor operation signal | Stowing / Return switch Return
Back door OPEN Ignition switch off Park / Neutral position switch P position |
10 to 14 V |
| RCL- (Y2-6) - E (Y2-8) | L - W-B | Reclining motor operation signal | Power rear seat switch Backward
Back door OPEN Lock switch UNLOCK |
10 to 14 V |
If the result is not as specified, the fold seat control ECU may have a malfunction.