The fold seat control ECU receives a switch operation signal from the fold seat switch and activates the folding motor. At this time, the Hall IC (seat cushion position sensor) detects the actuation signal. The fold seat control ECU uses signals from the Hall IC (seat cushion position sensor) to detect if an object is caught or if any other abnormal condition has occurred.
Remove the fold seat control ECU with the connectors still connected.
Measure the voltage of the connectors.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Z2-1 (FLD+) - Z2-5 (FLD-) | Stowing / Return switch STOWING
Back door OPEN Ignition switch off Park / Neutral position switch P position |
10 to 14 V |
| Z2-5 (FLD-) - Z2-1 (FLD+) | Stowing / Return switch RETURN
Back door OPEN Ignition switch off Park / Neutral position switch P position |
10 to 14 V |
| Z3-23 (SFLD) - Z3-30 (SG1) | Motor is operating | Below 1 V - 10 to 14 V
Pulse generation |
| Z3-24 (SV1) - Z3-30 (SG1) | Back door OPEN | 9 to 14 V |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Y2-1 (FLD+) - Y2-5 (FLD-) | Stowing / Return switch STOWING
Back door OPEN Ignition switch off Park / Neutral position switch P position |
10 to 14 V |
| Y2-5 (FLD-) - Y2-1 (FLD+) | Stowing / Return switch RETURN
Back door OPEN Ignition switch off Park / Neutral position switch P position |
10 to 14 V |
| Y3-23 (SFLD) - Y3-30 (SG1) | Motor is operating | Below 1 V - 10 to 14 V
Pulse generation |
| Y3-24 (SV1) - Y3-30 (SG1) | Back door OPEN | 9 to 14 V |
NG
OK
Disconnect the Z1*1 or Y1*2 motor connector.
Disconnect the Z3*1 or Y3*2 ECU connector.
Measure the resistance of the wire harness side connectors.
| Tester Connection | Specified Condition |
|---|---|
| Z2-1 (FLD+) - Z1-8 (FWD) | Below 1 Ω |
| Z2-5 (FLD-) - Z1-10 (BACK) | Below 1 Ω |
| Z3-23 (SFLD) - Z1-3 (HLS) | Below 1 Ω |
| Z3-24 (SV1) - Z1-6 (HLV) | Below 1 Ω |
| Z3-30 (SG1) - Z1-16 (HLG) | Below 1 Ω |
| Z2-1 (FLD+) - Body ground | 10 kΩ or higher |
| Z2-5 (FLD-) - Body ground | 10 kΩ or higher |
| Z3-23 (SFLD) - Body ground | 10 kΩ or higher |
| Z3-24 (SV1) - Body ground | 10 kΩ or higher |
| Z3-30 (SG1) - Body ground | 10 kΩ or higher |
| Tester Connection | Specified Condition |
|---|---|
| Y2-1 (FLD+) - Y1-8 (FWD) | Below 1 Ω |
| Y2-5 (FLD-) - Y1-10 (BACK) | Below 1 Ω |
| Y3-23 (SFLD) - Y1-3 (HLS) | Below 1 Ω |
| Y3-24 (SV1) - Y1-6 (HLV) | Below 1 Ω |
| Y3-30 (SG1) - Y1-16 (HLG) | Below 1 Ω |
| Y2-1 (FLD+) - Body ground | 10 kΩ or higher |
| Y2-5 (FLD-) - Body ground | 10 kΩ or higher |
| Y2-23 (SFLD) - Body ground | 10 kΩ or higher |
| Y3-24 (SV1) - Body ground | 10 kΩ or higher |
| Y3-30 (SG1) - Body ground | 10 kΩ or higher |
OK
NG