The fold seat control ECU receives a switch operation signal from the power rear seat switch and the fold seat switch, and activates the reclining motor. At this time, the Hall IC (seatback position sensor) detects the actuation of the seatback and sends a seatback actuation signal to the fold seat control ECU. The fold seat control ECU uses signals from the Hall IC (seatback position sensor) to detect if an object is caught or if any other abnormal condition has occurred.
Remove the fold seat control ECU with the connectors still connected.
Measure the voltage of the connectors.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Z2-2 (RCL+) - Z2-6 (RCL-) | Power rear seat switch FORWARD
Back door OPEN Lock switch UNLOCK |
10 to 14 V |
| Z2-6 (RCL-) - Z2-2 (RCL+) | Power rear seat switch BACKWARD
Back door OPEN Lock switch UNLOCK |
10 to 14 V |
| Z3-22 (SRCL) - Z3-36 (SG2) | Motor is operating | Below 1 V - 10 to 14 V
Pulse generation |
| Z3-25 (SV2) - Z3-36 (SG2) | Back door OPEN | 9 to 14 V |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Y2-2 (RCL+) - Y2-6 (RCL-) | Power rear seat switch FORWARD
Back door OPEN Lock switch UNLOCK |
10 to 14 V |
| Y2-6 (RCL-) - Y2-2 (RCL+) | Power rear seat switch BACKWARD
Back door OPEN Lock switch UNLOCK |
10 to 14 V |
| Y3-22 (SRCL) - Y3-36 (SG2) | Motor is operating | Below 1 V - 10 to 14 V
Pulse generation |
| Y3-25 (SV2) - Y3-36 (SG2) | Back door OPEN | 9 to 14 V |
NG
OK
Disconnect the Z2*1 and Z3*1, or Y2*2 and Y3*2 ECU connectors.
Disconnect the Z4*1 and Z5*1, or Y4*2 and Y5*2 motor connectors.
Measure the resistance of the wire harness side connectors.
| Tester Connection | Specified Condition |
|---|---|
| Z2-2 (RCL+) - Z4-1 (FWD) | Below 1 Ω |
| Z2-6 (RCL-) - Z4-2 (BACK) | Below 1 Ω |
| Z3-22 (SRCL) - Z5-1 (HLS) | Below 1 Ω |
| Z3-25 (SV2) - Z5-3 (HLV) | Below 1 Ω |
| Z3-36 (SG2) - Z5-2 (HLG) | Below 1 Ω |
| Z2-2 (RCL+) - Body ground | 10 kΩ or higher |
| Z2-6 (RCL-) - Body ground | 10 kΩ or higher |
| Z3-22 (SRCL) - Body ground | 10 kΩ or higher |
| Z3-25 (SV2) - Body ground | 10 kΩ or higher |
| Z3-36 (SG2) - Body ground | 10 kΩ or higher |
| Tester Connection | Specified Condition |
|---|---|
| Y2-2 (RCL+) - Y4-1 (FWD) | Below 1 Ω |
| Y2-6 (RCL-) - Y4-2 (BACK) | Below 1 Ω |
| Y3-22 (SRCL) - Y5-1 (HLS) | Below 1 Ω |
| Y3-25 (SV2) - Y5-3 (HLV) | Below 1 Ω |
| Y3-36 (SG2) - Y5-2 (HLG) | Below 1 Ω |
| Y2-2 (RCL+) - Body ground | 10 kΩ or higher |
| Y2-6 (RCL-) - Body ground | 10 kΩ or higher |
| Y3-22 (SRCL) - Body ground | 10 kΩ or higher |
| Y3-25 (SV2) - Body ground | 10 kΩ or higher |
| Y3-36 (SG2) - Body ground | 10 kΩ or higher |
OK
NG
Check if the motor rotates smoothly when the battery is connected to the reclining motor.
| Tester Connection | Specified Condition |
|---|---|
| Battery positive (+) → Z4-1 (FWD)
Battery negative (-) → Z4-2 (BACK) |
FORWARD |
| Battery positive (+) → Z4-2 (BACK)
Battery negative (-) → Z4-1 (FWD) |
BACKWARD |
| Tester Connection | Specified Condition |
|---|---|
| Battery positive (+) → Y4-1 (FWD)
Battery negative (-) → Y4-2 (BACK) |
FORWARD |
| Battery positive (+) → Y4-2 (BACK)
Battery negative (-) → Y4-1 (FWD) |
BACKWARD |
OK
NG