The fold seat control ECU receives a switch operation signal from the fold seat switch and activates the release actuator. The release actuator releases the lock of the stowed seat based on a drive voltage received from the ECU.
Remove the fold seat control ECU with the connector still connected.
Measure the voltage of the connector.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Z2-3 (RACT) - Body ground | Stowing/Return switch RETURN | 10 to 14 V |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Y2-3 (RACT) - Body ground | Stowing/Return switch RETURN | 10 to 14 V |
NG
OK
Disconnect the Z1*1 or Y1*2 motor connector.
Disconnect the Z2*1 or Y2*2 ECU connector.
Measure the resistance of the wire harness side connectors.
| Tester Connection | Specified Condition |
|---|---|
| Z2-3 (RACT) - Z1-9 (ACT) | Below 1 Ω |
| Z1-2 (E) - Body ground | Below 1 Ω |
| Z2-3 (RACT) - Body ground | 10 kΩ or higher |
| Tester Connection | Specified Condition |
|---|---|
| Y2-3 (RACT) - Y1-9 (ACT) | Below 1 Ω |
| Y1-2 (E) - Body ground | Below 1 Ω |
| Y2-3 (RACT) - Body ground | 10 kΩ or higher |
OK
NG