The left and right seats each have a fold lock switch that detects the lock condition of the seat legs to the floor when the seat is in the stowed state. If the fold lock switch detects an unlock condition, the 3rd seat indicator on the combination meter will come on.
Remove the fold seat control ECU with the connectors still connected.
Measure the voltage of the connector.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Z3-37 (LCKR) - Body ground | Fold lock switch UNLOCK | Below 1 V |
| Z3-37 (LCKR) - Body ground | Fold lock switch LOCK | 10 to 14 V |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Y3-37 (LCKR) - Body ground | Fold lock switch UNLOCK | Below 1 V |
| Y3-37 (LCKR) - Body ground | Fold lock switch LOCK | 10 to 14 V |
NG
OK
Disconnect the Z1*1 or Y1*2 motor connector.
Disconnect the Z2*1 or Y2*2 connector.
Measure the resistance of the wire harness side connectors.
*1: for LH
*2: for RH
| Tester Connection | Specified Condition |
|---|---|
| Z3-37 (LCKR) - Z1-15 (FLS+) | Below 1 Ω |
| Z1-1 (E) - Body ground | Below 1 Ω |
| Z3-37 (LCKR) - Body ground | 10 kΩ or higher |
| Tester Connection | Specified Condition |
|---|---|
| Y3-37 (LCKR) - Y1-15 (FLS+) | Below 1 Ω |
| Y1-1 (E) - Body ground | Below 1 Ω |
| Y3-37 (LCKR) - Body ground | 10 kΩ or higher |
OK
NG
Measure the resistance of the switch.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 15 (FLS+) - 1 (E) | Fold lock switch UNLOCK | Below 1 Ω |
| 15 (FLS+) - 1 (E) | Fold lock switch LOCK | 10 kΩ or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 15 (FLS+) - 1 (E) | Fold lock switch UNLOCK | Below 1 Ω |
| 15 (FLS+) - 1 (E) | Fold lock switch LOCK | 10 kΩ or higher |
OK
NG