This circuit supplies power to operate the power door lock system.
Remove the DR LOCK fuse from the main body ECU.
Remove the ECU-B and FR DOOR fuses from the engine room No. 1 relay block.
Measure the resistance of the fuses.
Below 1 Ω
OK
NG
Disconnect the G59, 4A, 4M and 4K ECU connectors.
Measure the voltage of the wire harness side connectors.
| Tester Connection | Specified Condition |
|---|---|
| 4M-1 (ALTB) - Body ground | 10 to 14 V |
| 4K-1 (BECU) - Body ground | 10 to 14 V |
| 4K-9 (BATB) - Body ground | 10 to 14 V |
Measure the resistance of the wire harness side connectors.
| Tester Connection | Specified Condition |
|---|---|
| G59-1 (GND1) - Body ground*1 | Below 1 Ω |
| 4A-3 (GND2) - Body ground | Below 1 Ω |
OK
NG